12
• When using Microsoft Excel 2010 (32-bit version), Microsoft Excel 2013 (32-bit version), or Microsoft Excel 2016 (32-bit
version), install Visual Basic
for Applications (abbreviated as VBA below). If VBA is not installed, the error message below
is displayed when the "Layout setting" screen is started, and layout settings cannot be configured.
"This workbook has lost its VBA Project, ActiveX Controls and any other programmability-related features."
• The saving format of a report file output by the report function is the xls format. Some of the functions added to Microsoft
Excel 2007 and later cannot be used.
• Microsoft Excel 2010 (64-bit version) is not supported.
• Microsoft Excel 2013 (64-bit version) is not supported.
• Microsoft Excel 2016 (64-bit version) is not supported.
Considerations for other functions
■
Access target CPU setting
• When rewriting the configuration tool settings, turning the power OFF to ON, or resetting the CPU module, the high speed
data logger module is prepared to communicate with the access target CPU module. Therefore, if a large number of access
target CPU modules are set, several minutes are required for this preparation.
• The following conditions may affect the general sampling, file transfer function, and e-mail function: when the CPU module
which does not exist in the access target CPU module is set, or the high speed data logger module cannot communicate
with the access target CPU module temporary because of the power interruption of access target CPU module or network
failure. Use the high speed data logger modules with the status that can communicate with the CPU module set as access
target CPU module.
■
Time synchronization function
• If implementing the time synchronization with the CPU module, it will change the time of the high speed data logger
module. When the CPU module's time is changed, the high speed data logger module's time may be greatly changed.
• Since there is inaccuracy in the clock element of the CPU module and the high speed data logger module, the time may be
moved slightly forward or backward when the time is synchronized. Since changing the time of the high speed data logger
module affects the time stamp, as well as the following determination of the cycles and of the time: data logging, event
logging, and reports, configure the module to synchronize its time at the required minimum range.
Considerations for accessing a high speed data logger module
■
Web browser operations and settings
• In the local area network (LAN) setting of the Web browser, do not set a proxy server for the local address.
(
■
FTP server function
• Because of FTP client side application restrictions, if the user name or password is input incorrectly, end the FTP operation
and redo the FTP connection from the beginning. FTP may not operate correctly by reentering the correct user name or
password with the 'user' FTP command.
• The maximum number of simultaneous connections to the FTP server is 10. However, depending on the FTP client, it may
make multiple simultaneous connections, so an FTP client may not be able to login even if 10 clients are not connected. In
this situation, shutdown all the FTP clients, then restart and connect them.
• When transferring many files at once with FTP, a 426 error (data connection error) may occur. In this situation, split the files
into multiple parts then transfer them separately.
• When Internet Explorer is used for FTP access, the user authentication screen may not be displayed due to the Internet
Explorer specification. In such a case, enter the high speed data logger module's address in the following format.
ftp://<user name>:<password>@<high speed data logger module's address or hostname>/
Содержание RD81DL96
Страница 2: ......
Страница 80: ...78 7 INSTALLATION AND UNINSTALLATION 7 2 Uninstallation Procedure MEMO ...
Страница 115: ...8 OPERATION EXAMPLE 8 3 Creating Reports from Continuously Logged Data 113 8 MEMO ...
Страница 117: ...APPX Appendix 1 External Dimensions 115 A MEMO ...
Страница 119: ...I 117 MEMO ...
Страница 123: ......