3. Specifications
Model
Noise level (50/60 Hz)
External static pressure
Cooling mode: – 5
°
CDB ~ 43
°
CDB (0
°
CDB ~ 43
°
CDB with outdoor unit at lower position)
Heating mode: – 20
°
CWB ~ 15.5
°
CWB
Cooling mode: 21
°
CDB ~ 43
°
CDB
Heating mode: – 12.5
°
CWB ~ 20
°
CWB
5. Space required around unit
[Fig. 5.0.1] (P.2)
<A> Top view
<B> Side view
<C> When there is little space up to an obstruction
A
Front
B
No restrictions on wall height (left and right)
C
Air outlet guide (Procured at the site)
D
Must be open
E
Wall height (H)
F
No restrictions on wall height
(mm)
L
1
L
2
450
450
(1) Basic space required
(2) When there is an obstruction above the unit
(3) When inlet air enters from right and left sides of unit
•
Wall heights “H” of the front and the back sides shall be within total height of
unit.
•
When wall height “H” exceeds total height of unit, add “h” dimension to L
1
and
L
2
of the Fig. 5.0.1.
“h” = wall height “H'” – total height of unit
(4) When unit is surrounded by walls
Note:
•
Wall heights “H” of the front and the back sides shall be lower than either
the front or the back panel.
•
If the panel height is exceeded, add the “h” dimension of the Fig. 5.0.1 to
L
1
and L
2
.
(mm)
L
1
L
2
450
450
Example:
When the “h” dimension is 100 mm,
the L
1
dimension becomes 450 + 100 = 550 mm.
(5) Collective installation and continuous installation
•
Space required for collective installation and continuous installation:
When installing several units, provide the space between each block consider-
ing passage for air and people.
•
Open in two directions.
•
In case of wall height “H” exceeds total height of unit, add “h” dimension (h =
wall height “H'” – total height of unit) to * marked dimension.
•
If there is a wall at both the front and the rear of the unit, install up to four units
(Every 3 units in the case of P450 ~ P650.) consecutively in the side direction
and provide a space of 1000 mm or more as inlet space/passage space for
each four units (Every 3 units in the case of P450 ~ P650.) .
6. Lifting method
[Fig. 6.0.1] (P.2)
Caution:
Be very careful to carry product.
- Do not have only one person to carry product if it weighs more than 20 kg.
- PP bands are used to pack some products. Do not use them as a mean for transportation because they are dangerous.
- Do not touch heat exchanger fins with your bare hands. Otherwise you may cut your hands.
- Tear plastic packaging bag and scrap it so that children cannot play with it. Otherwise plastic packaging bag may suffocate children to death.
- When carrying outdoor unit, be sure to support it at four points. Carrying with 3-point support may make outdoor unit unstable, resulting in it falling.
4. Confirmation of parts attached
Total capacity
Model
Quantity
Standard type
Fresh air intake
type
Indoor unit
Operation
temperature
PURY-P200
56 dB<A>
1 ~ 15
PURY-P250
57 dB<A>
1 ~ 16
PURY-P300
59 dB<A>
1 ~ 16
PURY-P350
60 dB<A>
1 ~ 20
PURY-P400
61 dB<A>
1 ~ 24
0 Pa
50 ~150 %
20 ~ 250
Model
Noise level (50/60 Hz)
External static pressure
Cooling mode: – 5
°
CDB ~ 43
°
CDB (0
°
CDB ~ 43
°
CDB with outdoor unit at lower position)
Heating mode: – 20
°
CWB ~ 15.5
°
CWB
Cooling mode: 21
°
CDB ~ 43
°
CDB
Heating mode: – 12.5
°
CWB ~ 20
°
CWB
Total capacity
Model
Quantity
Standard type
Fresh air intake
type
Indoor units
Operation
temperature
PURY-P450
60/61 dB<A>
1 ~ 24
PURY-P500
60/61 dB<A>
1 ~ 24
PURY-P550
61/62 dB<A>
1 ~ 24
PURY-P600
61/62 dB<A>
1 ~ 32
PURY-P650
62/62.5 dB<A>
1 ~ 32
0 Pa
50 ~150 %
20 ~ 250
Model
Model
Model
P200 ~ P350
P400
P450 ~ P650
P200 ~ P350
P400
P450 ~ P650
P200 ~ P350
P400
P450 ~ P650
1
Conduit mounting plate (ø53)
-
1pc.
1pc.
4
Conduit mounting plate (ø27)
1pc.
-
-
7
Connecting pipe (Low pressure)
1pc.
1pc.
1pc.
2
Conduit mounting plate (ø46)
-
1pc.
1pc.
5
Tappinng screw M4
2pcs.
2pcs.
2pcs.
8
Packing (Low press. pipe)
1pc.
1pc.
1pc.
3
Conduit mounting plate (ø33)
1pc.
-
-
6
Connecting pipe (High pressure)
1pc. (Flare)
2pcs. (Flange)
1pc. (Flange)
9
Packing (High press. pipe)
-
1pc.
1pc.