3-1. UNIT CONSTRUCTION
15
20
25
32
40
50
63
71
80
100
125
140
–
20VCM-E(2)
25VCM-E(2)
32VCM-E(2)/32VBM-E
40VCM-E(2)/40VBM-E
50VBM-E
63VBM-E
–
80VBM-E
100VBM-E
125VBM-E
–
–
20VLMD-E
25VLMD-E
32VLMD-E
40VLMD-E
50VLMD-E
63VLMD-E
–
80VLMD-E
100VLMD-E
125VLMD-E
–
15VMS1-E
20VMS1-E/ VMA-E
25VMS1-E/ VMA-E
32VMS1-E/ VMA-E
40VMS1-E/ VMA-E
50VMS1-E/ VMA-E
63VMS1-E/ VMA-E
71VMA-E
80VMH-E/ VMA-E
100VMH-E/ VMA-E
125VMH-E/ VMA-E
140VMH-E/ VMA-E
15VBM-E
20VBM-E
25VBM-E
32VHM-E
40VHM-E
50VHM-E
63VKM-E
–
–
100VKM-E
–
–
–
20VLEM-E/VKM-E
25VLEM-E/VKM-E
32VLEM-E/VKM-E
40VLEM-E/VKM-E
50VLEM-E
63VLEM-E
–
–
–
–
–
–
20VLRM-E
25VLRM-E
32VLRM-E
40VLRM-E
50VLRM-E
63VLRM-E
–
–
–
–
–
–
–
–
–
40VKM-E
–
63VKM-E
–
–
100VKM-E
125VKM-E
–
PLFY-P
PLFY-P
PEFY-P
PKFY-P
PCFY-P
PFFY-P
PFFY-P
–
–
–
–
–
–
–
–
80VMH-E-F
–
–
140VMH-E-F
PEFY-P
Capacity
Model
Cassette Ceiling
4-way flow 2-way flow
–
20VBM-E
25VBM-E
32VBM-E
40VBM-E
–
–
–
–
–
–
–
PMFY-P
1-way flow
Ceiling
Concealed
Ceiling
Suspended
Ceiling
Concealed
(Fresh Air) *1
Wall
Mounted
Floor standing
Exposed
Concealed
Remote
controller
Name
Model number
Functions
M-NET remote controller
PAR-F27MEA-E
• A handy remote controller for use in conjunction
with the Melans centralized management system.
• Addresses must be set.
• Addresses setting is not necessary.
MA remote controller
PAR-21MAA
Outdoor unit
Capacity
Type 15 ~ Type 125
1 ~ 8 unit
50% ~130% of outdoor unit capacity *2
Type 15 ~ Type 140
1 ~ 10 unit
Indoor
unit that
can be
connected
Number of units
Total system wide capacity
4HP
5HP
6HP
PUMY-P100VHMB(-BS)
PUMY-P100VHMBR1(-BS)
PUMY-P100VHMBR2(-BS)
PUMY-P100YHMB(-BS)
PUMY-P100YHMBR1(-BS)
PUMY-P100YHMBR2(-BS)
PUMY-P125VHMB(-BS)
PUMY-P125VHMBR1(-BS)
PUMY-P125VHMBR2(-BS)
PUMY-P125YHMB(-BS)
PUMY-P125YHMBR1(-BS)
PUMY-P125YHMBR2(-BS)
PUMY-P140VHMB(-BS)
PUMY-P140VHMBR1(-BS)
PUMY-P140VHMBR2(-BS)
PUMY-P140YHMB(-BS)
PUMY-P140YHMBR1(-BS)
PUMY-P140YHMBR2(-BS)
1 ~ 12 unit
Branching pipe
components
Branch header
(2 branches)
Branch header
(4 branches)
Branch header
(8 branches)
CMY-Y62-G-E
CMY-Y64-G-E
CMY-Y68-G-E
*1. PUMY-P·YHMB is connectable to Fresh Air type indoor unit.
It is possible to connect 1 Fresh Air type indoor unit to 1 outdoor unit. (1:1 system)
Operating temperature range (outdoor temperature) for fresh air type indoor units differ from other indoor units.
Refer to 3-2(3).
*2. When the indoor unit of Fresh Air type is connected with the outdoor unit, the maximum connectable total indoor unit
capacity is 110% (100% in case of heating below -5
:
[23˚F]).
Decorative panel
OVERVIEW OF UNITS