3 phase, 50Hz, 400V
13
Munsell 3Y 7.8/1.1
Linear Expansion Valve
Hermetic
Inverter
—
Plate fin coil
Propeller fan
%
2
0.060+0.060
100(3,530)
Reverse cycle
950(37-3/8)
330+30(13+1-3/16)
1,350(53-1/8)
130(287)
R410A
4.6(10.1)
1.40(FV50S)
9.52(3/8)
15.88(5/8)
Flared
Flared
Max. 30m
Max. 75m
PUHZ-SW100YHA-BS.UK
PUHZ-SW120YHA-BS.UK
PUHZ-SW100YHA.UK
PUHZ-SW120YHA
A
kW
W
kW
*
/min(CFM)
dB
dB
mm(in.)
mm(in.)
mm(in.)
kg(lbs)
kg(lbs)
L
mm(in.)
mm(in.)
Power supply (phase, cycle, voltage)
Max.
current
External finish
Refrigerant control
Compressor
Model
Motor
output
Starter
type
Protection
devices
Crankcase heater
Heat exchanger
Fan Fan(drive)
%
No.
Fan motor output
Airflow
Defrost method
Noise level
Dimensions
Weight
Refrigerant
Charge
Oil
(Model)
Pipe size O.D.
Connection method
Between the indoor &
outdoor unit
Cooling
Heating
W
D
H
Liquid
Gas
Indoor side
Outdoor side
Height difference
Piping length
Service Ref.
OUTDOOR UNIT
REFRIGERANT
PIPING
ANB33FNDMT
2.5
ANB42FNDMT
2.5
HP switch
LP switch
Discharge thermo
Comp.surface thermo
Over current detection
49
51
50
52
OCH533A