42
!
!
!
. Outdoor Unit
1. Specifications
Notes :
Unit converter
kcal
=kW x 860
BTU/h =kW x 3,412
cfm
=m
3
/min x 35.31
lb
=kg / 0.4536
1. Nominal cooling conditions(subject to JIS B8615-1)
Indoor:27˚CDB/19˚CWB(81˚FDB/66˚FWB), Outdoor:35˚CDB(95˚FDB)
Pipe length:7.5m(24-9/16ft.), Level difference:0m(0ft.)
2. Nominal heating conditions(subject to JIS B8615-1)
Indoor:20˚CDB(68˚FDB), Outdoor:7˚CDB/6˚CWB(45˚FDB/43˚FWB)
Pipe length:7.5m(24-9/16ft.), Level difference:0m(0ft.)
3. External static pressure option is available (30Pa, 60Pa / 3.1mmH
2
O, 6.1mmH
2
O).
*Above specification data is
subject to rounding variation.
Model
PUHY-P250YJM-A(-BS)
3-phase 4-wire 380-400-415V 50/60Hz
58
78
9.52(3/8) Brazed (12.7(1/2) Brazed,total length >= 90m)
22.2(7/8) Brazed
—
Propeller fan x 1
170
2,833
6,003
Inverter-control,
Direct-driven by motor
0.46 x 1
0 Pa (0 mmH
2
O)
Inverter scroll hermetic compressor
AC&R Works, MITSUBISHI
ELECTRIC CORPORATION
Inverter
6.8
0.035
MEL32
Pre-coated galvanized steel sheets
(+powder coating for -BS type)
<MUNSELL 5Y 8/1 or similar>
1,710(1,650 without legs) x 920 x 760
67-3/8(65 without legs) x 36-1/4 x 29-15/16
High pressure sensor, High pressure
switch at 4.15MPa (601 psi)
Over-heat protection,
Over-current protection
Over-heat protection
Thermal switch
R410A x 8.0kg (18lbs)
LEV and HIC circuit
200 (441)
Salt-resistant cross fin & copper tube
Copper pipe,tube-in-tube structure
—
—
Auto-defrost mode (Reversed refrigerant cycle)
WKD94G062
KE94C449
Installation Manual
Refrigerant conn. pipe
—
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual.
Due to continuing improvement, above specifications may be subject to change without notice.
Power source
*3
Sound pressure level (measured in anechoic room)
Power pressure level (measured in anechoic room)
Refrigerant
piping diameter
Set Model
Model
FAN
Compressor
External finish
Liquid pipe
Gas pipe
mm (in.)
Ty pe x Quantity
Air flow rate
Control,
Driving mechanism
Motor output
External static press.
Ty pe x Quantity
Manufacture
Starting method
Motor output
Case heater
Lubricant
L/s
cfm
kW
kW
kW
External dimension HxWxD
Protection devices
mm
in.
kg (lbs)
mm (in.)
mm (in.)
High pressure protection
Refrigerant
Net weight
Heat exchanger
HIC circuit (HIC: Heat Inter-Changer)
Pipe between unit
and distributor
Defrosting method
Ty pe x original charge
Control
Liquid pipe
Drawing
Optional parts
Remarks
External
Wiring
Standard
attachment
Document
Accessory
Gas pipe
Inverter circuit
(COMP. / FAN)
Compressor
Fan motor
m
3
/ min
mm (in.)
dB <A>
dB <A>
PUHY-P500YSJM-A(-BS)
3-phase 4-wire 380-400-415V 50/60Hz
61
81
15.88(5/8) Brazed
28.58(1-1/8) Brazed
PUHY-P250YJM-A(-BS)
Propeller fan x 1
170
2,833
6,003
Inverter-control,
Direct-driven by motor
0.46 x 1
0 Pa (0 mmH
2
O)
Inverter scroll hermetic compressor
AC&R Works, MITSUBISHI
ELECTRIC CORPORATION
Inverter
6.8
0.035
MEL32
Pre-coated galvanized steel sheets
(+powder coating for -BS type)
<MUNSELL 5Y 8/1 or similar>
1,710(1,650 without legs) x 920 x 760
67-3/8(65 without legs) x 36-1/4 x 29-15/16
High pressure sensor, High pressure
switch at 4.15MPa (601 psi)
Over-heat protection,
Over-current protection
Over-heat protection
Thermal switch
R410A x 8.0kg (18lbs)
LEV and HIC circuit
200 (441)
Salt-resistant cross fin & copper tube
Copper pipe,tube-in-tube structure
9.52 (3/8) Brazed
22.2 (7/8) Brazed
Auto-defrost mode (Reversed refrigerant cycle)
WKD94G065
KE94C449
Installation Manual
Refrigerant conn. pipe
Outdoor Tw inning kit: CMY-Y100VBK 2
PUHY-P250YJM-A(-BS)
Propeller fan x 1
170
2,833
6,003
Inverter-control,
Direct-driven by motor
0.46 x 1
0 Pa (0 mmH
2
O)
Inverter scroll hermetic compressor
AC&R Works, MITSUBISHI
ELECTRIC CORPORATION
Inverter
6.8
0.035
MEL32
Pre-coated galvanized steel sheets
(+powder coating for -BS type)
<MUNSELL 5Y 8/1 or similar>
1,710(1,650 without legs) x 920 x 760
67-3/8(65 without legs) x 36-1/4 x 29-15/16
High pressure sensor, High pressure
switch at 4.15MPa (601 psi)
Over-heat protection,
Over-current protection
Over-heat protection
Thermal switch
R410A x 8.0kg (18lbs)
200 (441)
Salt-resistant cross fin & copper tube
Copper pipe,tube-in-tube structure
9.52 (3/8) Brazed
22.2 (7/8) Brazed
KE94C449
PUHY-P750YSJM-A(-BS)
3-phase 4-wire 380-400-415V 50/60Hz
63.5
83.5
19.05(3/4) Brazed
34.93(1-3/8) Brazed
PUHY-P350YJM-A(-BS)
Propeller fan x 1
210
3,500
7,415
Inverter-control,
Direct-driven by motor
0.46 x 1
0 Pa (0 mmH
2
O)
Inverter scroll hermetic compressor
AC&R Works, MITSUBISHI
ELECTRIC CORPORATION
Inverter
9.9
0.045
MEL32
Pre-coated galvanized steel sheets
(+powder coating for -BS type)
<MUNSELL 5Y 8/1 or similar>
1,710(1,650 without legs) x 1,220 x 760
67-3/8(65 without legs) x 48-1/16 x 29-15/16
High pressure sensor, High pressure
switch at 4.15MPa (601 psi)
Over-heat protection,
Over-current protection
Over-heat protection
Thermal switch
R410A x 11.5kg (26lbs)
LEV and HIC circuit
250 (552)
Salt-resistant cross fin & copper tube
Copper pipe,tube-in-tube structure
12.7(1/2) Brazed
28.58 (1-1/8) Brazed
Auto-defrost mode (Reversed refrigerant cycle)
WKD94G067
KE94C449
Installation Manual
Refrigerant conn. pipe
Outdoor Tw inning kit: CMY-Y200VBK 2
PUHY-P400YJM-A(-BS)
Propeller fan x 1
210
3,500
7,415
Inverter-control,
Direct-driven by motor
0.46 x 1
0 Pa (0 mmH
2
O)
Inverter scroll hermetic compressor
AC&R Works, MITSUBISHI
ELECTRIC CORPORATION
Inverter
10.1
0.045
MEL32
Pre-coated galvanized steel sheets
(+powder coating for -BS type)
<MUNSELL 5Y 8/1 or similar>
1,710(1,650 without legs) x 1,220 x 760
67-3/8(65 without legs) x 48-1/16 x 29-15/16
High pressure sensor, High pressure
switch at 4.15MPa (601 psi)
Over-heat protection,
Over-current protection
Over-heat protection
Thermal switch
R410A x 11.5kg (26lbs)
250 (552)
Salt-resistant cross fin & copper tube
Copper pipe,tube-in-tube structure
15.88 (5/8) Brazed
28.58 (1-1/8) Brazed
KE94C449
Содержание PUHY-P-YSJM-A
Страница 1: ...DATA BOOK AIR CONDITIONING SYSTEMS MODEL PUHY P Y S JM A PFAV P VM E F ...
Страница 2: ......
Страница 94: ...91 2 Sample control wiring Different refrigerant group operation Refer to the section 3 2 1 Address Setting ...
Страница 97: ...94 3 Emergency Operation Mode a a a b c d a c ...
Страница 98: ...95 b a a a b a b b b ...
Страница 100: ...97 ...
Страница 101: ...98 ...
Страница 103: ......