Main menu list
Main
menu
Setting and display items
Setting details
Operation Vane · 3D i-See · Vent.
(Vane.Vent. (Lossnay))
Vane: Use to set the vertical air direction.
Louver: Use to set the horizontal air direction.
3D i-See sensor: This setting is available only for the air conditioners that
support easy setting function of motion sensing air direction.
Vent: Use to set the amount of ventilation.
High power *
3
Use to reach the comfortable room temperature quickly.
•
Units can be operated in the High-power mode for up to 30 minutes.
Comfort Manual
vane angle
Vertical air direction
• Sets the vertical airflow direction (vane) of each unit.
Horizontal air direction
• Sets the horizontal airfow direction (vane) of each unit.
3D i-See sensor Use to set the following functions for 3D i-See sensor.
• Air distribution • Energy saving option • Seasonal airflow
Timer
Timer
ON/OFF timer *
1
Use to set the operation ON/OFF times.
• Time can be set in 5-minute increments.
Auto-OFF
timer
Use to set the Auto-OFF time.
• Time can be set to a value from 30 to 240 in 10-minute increments.
Weekly timer
*
1,
*
2
Use to set the weekly operation ON/OFF times.
• Up to 8 operation patterns can be set for each day.
(Not valid when the ON/OFF timer is enabled.)
OU silent mode *
1,
*
3
Use to set the time periods in which priority is given to quiet operation of
outdoor units over temperature control. Set the Start/Stop times for each day
of the week.
•Select the desired silent level from ˝Normal,˝ ˝Middle,˝ and ˝Quiet.˝
Night setback
*
1
Use to make Night setback settings.
• Select ˝Yes˝ to enable the setting, and ˝No˝ to disable the setting. The temperature
range and the start/stop times can be set.
Energy
saving
Restriction Temp. range *
2
Use to restrict the preset temperature range.
• Different temperature ranges can be set for different operation modes.
Operation lock
Use to lock selected functions.
•
The locked functions cannot be operated.
Energy
saving
Auto return *
2
Use to get the units to operate at the preset temperature after performing
energy saving operation for a specified time period.
• Time can be set to a value from 30 and 120 in 10-minute increments.
(This function will not be valid when the preset temperature ranges are restricted.)
Schedule *
1,
*
3
Set the start/stop times to operate the units in the energy saving mode for
each day of the week, and set the energy saving rate.
• Up to 4 energy saving operation patterns can be set for each day.
• Time can be set in 5-minute increments.
• Energy saving rate can be set to a value from 0% or 50 to 90% in 10% increments.
Energy data (for unit time,
month, and day)
Displays the amount of power consumption during operation.
• Unit time data: Data for the last one-month period can be displayed in 30-minute
units.
• Monthly/daily data: Data for the last 14-month period are displayed in day-and-
month-units.
* Data can be deleted.
* Data are obtained based on the power consumption estimated from the operating
state.
*
1
Clock setting is required.
*
2
1°C increments.
*
3
This function is available only when certain outdoor units are connected.