1. SPECIFICATIONS
MEE15K052
Model name
CMB-WP108V-GB1
Number of branch
8
Power source
1-phase 220-230-240 V
50 Hz
60 Hz
Power input
Cooling
kW
0.01/0.01/0.01
0.01/0.01/0.01
(220/230/240) Heating
kW
0.01/0.01/0.01
0.01/0.01/0.01
Current input
Cooling
A
0.05/0.05/0.05
0.05/0.05/0.05
(220/230/240) Heating
A
0.05/0.05/0.05
0.05/0.05/0.05
Sound pressure level (measured in anechoice room)
dB <A>
–
Applicable temperature range of installation site
°C (D.B.)
0~32
External finish
Galvanized steel plate
(Lower part drain pan: Pre-coated galvanized powder coating)
Connectable outdoor/heat source unit
–
Indoor unit capacity connectable to 1 branch
Model P80 or smaller
(Use optional joint pipe combing 2 branches when the total unit capacity exceeds P81)
External dimension H x W x D
mm
300 x 1,520 x 630
in.
11-13/16 x 59-7/8 x 24-13/16
Refrigerant piping
diameter
To outdoor/heat source unit
Connectable outdoor/heat source unit capacity
–
–
–
–
–
High press. Pipe
mm (in.)
O.D.
–
–
–
–
–
Low press. Pipe
mm (in.)
O.D.
–
–
–
–
–
Water piping
diameter
To Indoor unit
Inlet Pipe
mm (in.)
I.D.
20 (3/4)
Outlet Pipe
mm (in.)
I.D.
20 (3/4)
Field drain pipe size
mm (in.)
O.D. 32 (1-1/4)
Net weight
kg (lbs)
44 (98) [49 (109) with water]
Standard
attachment
Document
–
Accessory
Drain Connection pipe (with flexible hose and insulation)
Optional parts
–
Note
1.Works not included:
Installation/foundation work, electrical connection work, duct work, insulation work, power source switch,
and other items are not specified in this specifications.
2.The equipment is for water.
3.Install this product in a location where noise (refrigerant noise) emitted by the unit will not disturb the neighbors.
(For use in quiet environments with low background noise, position the Sub HBC CONTROLLER at least 5 m away from any indoor units.)
4.Please install the Sub HBC controller in a place where noise will not be an issue.
5.Please attach an expansion vessel (field supply).
6.Please use copper or plastic pipes for the water circuit. Do not use steel or stainless steel pipework.
Furthermore, when using copper pipework use a non-oxidative brazing method.
Oxidation of the pipework will reduce the pump life.
7.When brazing the pipes, be sure to braze, after covering a wet cloth to the insulation pipes of the units in order to prevent it from burning and shrinking by heat.
8.Please install an air purge valve where air will gather in the water circuit.
9.Please refer to the databook or the installation manual for the specified water quality.
10.This unit is not designed for outside installations.
11.Please always make water circulate or pull out the circulation water completely when not using it.
*Please do not use it as a drinking water.
12.Please do not use ground water and well water.
13.When installing the Sub HBC unit in an environment which may drop below 0 °C, please add antifreeze to the circulating water.
(Refer to the databook and the installation manual).
14.Can't use singleness. (MAIN HBC CONTROLLER is necessary)
0000003901.BOOK 64 ページ 2016年2月18日 木曜日 午前11時4分
Содержание PLFY-WP VBM-E
Страница 3: ...MEE15K052 ...
Страница 5: ...1 2 MEE15K052 ...
Страница 39: ...1 36 MEE15K052 ...
Страница 42: ...1 39 PLFY VBM MEE15K052 2 EXTERNAL DIMENSIONS 2 EXTERNAL DIMENSIONS PLFY WP32 40 50VBM E Unit mm ...
Страница 44: ...1 41 PLFY VBM MEE15K052 4 ELECTRICAL WIRING DIAGRAMS 4 ELECTRICAL WIRING DIAGRAMS PLFY WP32 40 50VBM E ...
Страница 63: ...1 60 MEE15K052 ...
Страница 79: ...1 76 MEE15K052 ...
Страница 89: ...1 86 MEE15K052 ...
Страница 90: ...2 1 HYBRID CITY MULTI 2 OUTDOOR HEAT SOURCE UNITS MEE15K052 YLM R2 SERIES 2 3 YLM WR2 SERIES 2 37 ...
Страница 91: ...2 2 MEE15K052 ...
Страница 125: ...2 36 MEE15K052 ...
Страница 155: ...3 2 MEE15K052 ...
Страница 169: ...3 16 MEE15K052 ...
Страница 183: ...3 30 MEE15K052 ...