2. EXTERNAL DIMENSIONS
MEE16K008_U
12(305) OR MORE
177-5/32(4500) OR LESS
137-25/32(3500) OR LESS
F
E
10-7/16(265) OR MORE
36/48
24/30
REFRIGERANT
PIPEø6.35
FLARED CONNECTION 1/4F
REFRIGERANT
PIPEø12.7
FLARED CONNECTION 1/2F
REFRIGERANT
PIPEø9.52
FLARED CONNECTION 3/8F
REFRIGERANT
PIPEø15.88
FLARED CONNECTION 5/8F
A
B
9-1/2 (241)
11
-1/16
(281)
11
-23/32
(298)
10-5/32 (258)
3(76)
3-1/8 (79.5)
C
3(76.5)
3-1/8 (79.5)
D
P.
NEMU
08~18
•
CAP
ACITY
OF EACH MODEL
AS FOLLOWING
PLFY
-P
.NEMU-E*
:08/12/15/18/24/30/36/48
WA
LL
CEILING HEIGHT
SPACE T
O THE
CEILING
GRILLE
FROM FLOOR 70-7/8(1800) OR MORE
INDOOR UNIT
INDOOR UNIT
FLOOR
BETWEEN INDOOR UNIT
OBSTRUCTION
CEILING
OR MORE
118-1/8(3000)
OR MORE
59-1/16(1500)
OR MORE
39-3/8(1000)
OR MORE
9/32(7)
OR MORE
E
FOR LESS
BETWEEN THE T
O
P
OF
UNIT
AND CEILING SLAB
NOTE1.PLEASE CHOOSE
THE GRILLE FROM
A ST
ANDARD GRILLE,
AUT
O-GRILLE.
2.REINFORCE
THE SUSPENSION BOL
T BY
EAR
THQUAKE RESIST
ANCE SUPPOR
TING MA
TERIAL
WHICH
USING FOR SWING PREVENTION IN
ACCORDANCING WITH
THE NECESSAR
Y OF EAR
THQUAKE
RESIST
ANCE ETC.SPECIALL
Y IN
THE CASE WITHOUT
CEILING MA
TERIAL, CONFIRM REINFORCING
3.AS FOR SUSPENSION BOL
T, PLEASE USE M10 OR W3/8. (PROCURED
AT
LOCAL
SITE)
4.AS FOR DRAIN PIPE, PLEASE USE VP-25(O.D. ø1-1/4"(ø32) PV
C
TUBE).
DRAIN PUMP
INCLUSION. RAISE IS MAX 70-7/18"(850mm) FROM
THE CEILING.
5.ELECTRICAL
BOX MA
Y BE REMOVED FOR
THE SER
VICE PURPOSE.
MAKE SURE
TO
SLACK
THE ELECTRICAL
WIRE LITTLE BIT
FOR
CONTROL/POWER WIRES CONNECTION. 6.THE HEIGHT
OF
THE INDOOR UNIT
IS
ABLE
TO
BE
ADJUSTED
WITH
THE GRILLE
AT
TA
CHED.
7.WHEN INST
ALLING
THE BRANCH DUCTS, BE SURE
TO
INSULA
TE
ADEQUA
TEL
Y.
OTHER
W
ISE CONDENSA
TION
AND DRIPPING MA
Y OCCUR.
(IT
BECOMES
THE CAUSE OF DEW DROPS/WEAR DEW
.)
8.AS FOR NECESSAR
Y INST
ALLA
TION/SER
VICE SP
ACE, PLEASE REFER
TO
THE RIGHT
A
T FIGURE.
9.OUTLINE DWG REFER
TO
EXCLUSIVE OUTLINE DWG WHEN INST
ALL
OPTION MUL
TIFUNCTION
CASEMENT
AND OPTION HIGH PERFORMANCE FIL
TER
CEILING
ø3-15/16(ø100) CUTTING OUT
HOLE
ø4-29/32(ø125) BURRING HOLE PITCH SELF-T
AP
4 SCREWS:3 PLACES
DET
AIL
DRA
W
ING OF FRESH
AIR INT
AKE HOLE
6-7/32
(158)
120
˚
120
˚
2
1
MAIN BODY
SUSPENSION BOL
T M10
OR W3/8 SCREW
POWER SUPPL
Y WIRE ENTR
Y
GRILLE
DRAIN PIPE
CONNECT
T
O
VP-25
CEILING
CONNECTING
TO
SOCKET
OR
A
TT
ACHED
FLEXIBLE
HOSE
(CONNECTING BY
VINYL
CHLORIDE
SERIES
ADHESIVE)
THE BOTT
OM OF
SUSPENSION BOL
T
THE BOTT
OM OF MOVE
EYE SENSOR
(17 )
+5
0
0
+3/16
2-9/32
(58)
1-31/32 TO
2-3/4
(50~70)
5-1/2
(140)
6-11/16
(170)
4-1/8
(105)
7-15/32
(190)
21/32
A
1-9/16
(40)
B
2-3/8
(60)
24-23/32(628)
GRILLE
CEILING
ø6-7/8(ø175) BURRING HOLE PITCH SELF-T
AP
4 SCREWS:4 PLACES
(BRANCH DUCT
HOLE)
ø5-29/32(ø150) CUTTING OUT
HOLE
(BRANCH DUCT
HOLE)
6-9/16
(167)
6-3/32
(155)
15-11/32(390)
3-17/32
(90)
3-15/16
(100)
3-15/16
(100)
3-17/32
(90)
13-25/32(350)
5-1/8
(130)
3-15/16
(100)
70
˚
(CEILING HOLE)
(SUSPENSION BOL
T PITCH)
(SUSPENSION BOLT PITCH)
(CEILING HOLE)
FRESH AIR INT
AKE HOLE
BRANCH DUCT HOLE
REMOTE CONTROLLER WIRE ENTR
Y
POWER SUPPL
Y
TERMINAL
BLOCK
INDOOR UNIT /OUTDOOR UNIT
CONNECTING TERMINAL
BED
(BOARD P
ACKAGING)
BRANCH DUCT HOLE HUMIDIFIER HOLE
+40
0
0
+1-9/16
(660 )
TERMINAL
BED
FOR REMOTE CONTROLLER
(BOARD P
ACKAGING)
25/32 TO
1-25/32
(20~45)
33-27/32 TO
35-13/16(860~910)
(25/32
)
(20)
26
25/32 TO
1-25/32
(20~45)
25/32 T
O
1-25/32
(20~45)
25/32 T
O
1-25/32
(20~45)
31-5/16
(795)
31-7/8 T
O
35-13/16(810
~910)
33-1/16(840)
33-1/16(840)
5-23/32
(145)
5-5/8
(145)
1/4(6)
5-23/32
(145)
5-23/32(145)
(2
5/32)
(20)
8-3/4
(222)
7-19/32
(193)
3-1/8(79.5)
5-1/8
(133)
D
C
REMOTE CONTROLLER WIRE ENTR
Y
GRILLE
ø5-29/32(ø150) CUTTING OUT
HOLE
(CONNECTING T
O
BRANCH
DUCT)
ø6-7/8(ø175) BURRING HOLE PITCH SELF-T
AP
4 SCREWS
:4 PLACES
(CONNECTING T
O
BRANCH
DUCT)
CEILING
17-23/32(450)
70
˚
VA
NE MOT
O
R(1 PCS/CONNER)
COMP
ANY
NAME
DISPLA
Y P
AR
T
*IN CASE OF ST
ANDARD GRILLE
WITHOUT
RADIA
TION SENSOR
*CAN INST
ALL
T
O
THE CONNER
EXCEPT
DRAIN PIPE CORNER
(BUT
NEED
TO
SELECT
FUNCTION
BY
REMOTE CONTROLLER)
AIR INT
AKE GRILLE
(AIR INT
AKE HOLE)
EASY
CORNER POCKET
DRAIN PUNCH HOLE
AUT
O
VA
NE(AIR
OUTLET
HOLE)
(AIR OUTLET
HOLE)
(AIR OUTLET HOLE)
(AIR INTAKE HOLE)
(AIR INT
AKE HOLE)
OPTION WIRELESS RECEIVING P
AR
T KIT
RECEIVING P
AR
T ST
ANDARD INST
ALLA
TION POSITION
*NONE IN
THE CASE OF ST
ANDARD GRILLE
20-7/8(530)
20-7/8(530)
37-13/32(950)
37-13/32(950)
20(508)
20(508)
3-1/2
(89)
1-15/32(37)
3-1/2
(89)
1-15/32
(37)
DEFROST/ST
AND BY
LAMP
OPERA
TION
LAMP
RECEIVING PA
RT
EMERGENCY
OPERA
TION
SWITCH <HEA
TING>
AND
EMERGENCY
UP/DOWN
SWITCH<DOWN>
EMERGENCY
OPERA
TION
SWITCH <COOLING>
AND
EMERGENCY
UP/DOWN
SWITCH<UP>
IN CASE OF OPTION WIRELESS RECEIVING P
AR
T KIT
RECEIVING P
AR
T
PLFY-P08, 12, 15, 18, 24, 30, 36, 48 NEMU-E
Unit : in.(mm)
0000004082.BOOK 11 ページ 2016年9月8日 木曜日 午後2時43分
Содержание PLFY-(E)P-NEMU-E
Страница 1: ...MODEL PLFY P NCMU E PLFY E P NEMU E NEW AIR CONDITIONING SYSTEMS ...
Страница 3: ...2 MEE16K008_U ...