3. Operation
■
About the operation method, refer to the operation manual that comes with each remote controller.
3.1. Turning ON/OFF
[ON] [OFF]
Press the [ON/OFF] button.
The ON/OFF lamp will light up in green,
and the operation will start.
Press the [ON/OFF] button again.
The ON/OFF lamp will come off, and
the operation will stop.
■
Operation status memory
Remote controller setting
Operation mode
Operation mode before the power was turned off
Preset temperature
Preset temperature before the power was turned off
Fan speed
Fan speed before the power was turned off
■
Settable preset temperature range
Operation mode
Preset temperature range
Cool/Dry
67 - 87 ºF/19 - 30 ºC
Heat
63 - 83 ºF/17 - 28 ºC
Auto
67 - 83 ºF/19 - 28 ºC
Fan/Ventilation
Not settable
Note:
Even if you press the ON/OFF button immediately after shutting down the operation is progress, the air conditioner will not start for about 3 minutes.
This is to prevent the internal components from being damaged.
3.2. Mode Selection
Press the [F1] button to go through the op-
eration modes in the order of “Cool”, “Dry”,
“Fan”, “Auto”, and “Heat”. Select the desired
operation mode.
Cool
Dry
Fan
Auto
Heat
•
Operation modes that are not available to
the connected outdoor unit models will not
appear on the display.
What the blinking mode icon means
The mode icon will blink when other indoor units in the same refrigerant
system (connected to the same outdoor unit) are already operated in a
different mode. In this case, the rest of the unit in the same group can
only be operated in the same mode.
Automatic operation
■
According to a set temperature, cooling operation starts if the room tem-
perature is too hot and heating operation starts if the room temperature
is too cold.
■
During automatic operation, if the room temperature changes and re-
mains 2.0 °C, 4 °F or more above the set temperature for 15 minutes,
the air conditioner switches to cool mode. In the same way, if the room
temperature remains 2.0 °C, 4 °F or more below the set temperature for
15 minutes, the air conditioner switches to heat mode.
F1
F2
F3
F4
83
F
83
F
Cool
Room
Auto
Set temp.
Mode
Temp.
Fan
Fri
Information for multi system air conditioner (Outdoor
unit: MXZ series)
■
Multi system air conditioner (Outdoor unit: MXZ series) can
connect two or more indoor units with one outdoor unit. According
to the capacity, 2 or more units can operate simultaneously.
• When you try to operate 2 or more indoor units with 1 outdoor unit
simultaneously, one for the cooling and the other for heating, the
operation mode of the indoor unit that operates earlier is selected.
The other indoor units that will start the operation later cannot operate,
indicating an operation state in blinking.
In this case, please set all the indoor units to the same operation
mode.
• There might be a case that the indoor unit, which is operating in “Auto”
mode. Cannot change over to the operating mode “Cool”/“Heat” and
becomes a state of standby.
• When indoor unit starts the operation while the defrosting of outdoor
unit is being done, it takes a few minutes (max. about 15 minutes) to
blow out the warm air.
• In the heating operation, though indoor unit that does not operate may
get warm or the sound of refrigerant flowing may be heard, they are
not malfunction. The reason is that the refrigerant continuously flows
into it.
3.3. Temperature setting
<Cool, Dry, Heat, and Auto>
Cool
Room
Auto
Set temp.
Mode
Temp.
Fan
Fri
84
F
84
F
Example display
(Centigrade in 0.5-degree increments)
F1
F2
F3
F4
83
F
83
F
Cool
Room
Auto
Set temp.
Mode
Temp.
Fan
Fri
Press the [F2] button to decrease the preset temperature, and press the
[F3] button to increase.
• Refer to the table on page 7 for the settable temperature range for dif
-
ferent operation modes.
• Preset temperature range cannot be set for Fan/Ventilation operation.
• Preset temperature will be displayed either in Centigrade in 0.5- or
1-degree increments, or in Fahrenheit, depending on the indoor unit
model and the display mode setting on the remote controller.
Cool mode
15 minutes (switches from
heating to cooling)
Set tempe2.0 °C, +4 °F
Set temperature
Set temperature -2.0 °C, -4 °F
15 minutes (switches from
cooling to heating)
BH79D659H01_EN.indd 7
8/5/2016 11:07:23 AM