4
ON/OFF –
TIMER SET
SET TEMP.
REMOTE CONTROLLER
MODE
TIMER ON/OFF CLOCK/TIMER
FAN SPEED AIR DISCHARGE
FILTER
AIR SWEEP
CHECK
TEST RUN
STAND BY
DEFROST
DRY COOL
AUTO FAN
HEAT
CENTRALLY CONTROLLED
˚F
SWING
FAN
SPEED
AUTO
RETURN
NOT AVAILABLE
˚F
CHECK MODE
FILTER
TIMER
TEST RUN
TIMER OFF
CLOCK AUTO AUTO
CHECK SET TEMP.
START STOP
F
1
2. Operation
2.5. Adjusting airflow direction
The vertical air vane helps select the vertical direction of the airflow.
1
Press AIR DISCHARGE button to select the vertical airflow direction.
• Each time you press the button, the option changes are displayed on the remote
controller, as shown below.
A
(swing)
→
B
→
C
→
D
→
E
→
A
• In cooling/drying mode with the fan speed set to LOW, every press on the button
will change the direction in the order of
A
,
B
,
D
,
A
. (
C
can not be set)
• If
D
or
E
is set, the angle will automatically revert to
B
after one hour of operation.
(Do not use
D
and
E
too often in cooling/drying mode with the fan speed set to
LOW, or condensation or dripping can occur.)
F
“AUTO RETURN” should be displayed.
• When the angle setting is
C
in cooling mode, switching the fan speed from HIGH
to LOW will cause the angle to revert to
B
automatically.
• The airflow direction can not be set with UP/DOWN while the SWING setting is being used.
• The arrow indicators are alternately displayed when the air sweep is in operation,
however they are not displayed when the air sweep is not in operation.
• The left/right guide vanes of PC(H) series and the guide vane of the PK(H) serises
can be changed manually.
2.6. Using the timer
1)
Set the current time
1
Press clock/timer button to display the “CLOCK”
B
.
Remote
CLOCK
→
AUTO
START
→
AUTO
STOP
→
No Display
controller display
A
2
Each time you press
TIMER SET
button, the time increases in increments of one minute.
Each time you press
TIMER SET
button, the time decreases in increments of one minute.
• Press and hold the button to rapidly change the time.
• The time changes in increments of one minute
→
ten minutes
→
in units of hour; in
this order.
• Approximately ten seconds after pressing the button, the display on the remote
controller will turn off.
(For Wireless Remote Controller)
1
Press the CLOCK button using a thin stick and blink the time
A
.
2
Press the
h
and
min
button to set the current time.
3
Press the CLOCK button using a thin stick.
2)
Set the time to start the unit as follows
1
Press clock/timer button to display
B
AUTO
START
.
2
Press
TIMER SET
button to set the time that you want the unit to start.
The start time is displayed at
A
.
(For Wireless Remote Controller)
1
Press the
AUTO START
button.
• Time can be set while the following symbol is blinking.
ON time :
B
START is blinking.
2
Use the
h
and
min
buttons to set the desired time.
3
To cancel the ON timer, press the
AUTO START
button.
3)
Set the time to stop the unit as follows
1
Press clock/timer button to display
C
AUTO
STOP
.
2
Press
TIMER SET
button to set the time that you want the unit to stop.
The stop time is displayed at
A
.
(For Wireless Remote Controller)
1
Press the
AUTO STOP
button.
• Time can be set while the following symbol is blinking.
OFF time :
C
STOP is blinking.
2
Use the
h
and
min
buttons to set the desired time.
3
To cancel the OFF timer, press the
AUTO STOP
button.
4)
Changing the set times
1
Press clock/timer button to display the time (CURRENT, START, STOP) you want
to change.
2
Press
TIMER SET
button to set the desired time.
• When change is made to either one of a pair, e.g., AUTO START or AUTO STOP,
set the time you need not to change to
. This display is available following
23:50.
(For Wireless Remote Controller)
Press the
AUTO START
or
AUTO STOP
to cancel the timer and repeat from 2) or 3).
↑
A
B
C
D
E
A
B
C
D
E
PL(H)
Swing
30°
45°
55°
70°
PK(H)*
Swing
10°
30°
60°
70°
PK12FK3
–
10°
30°
60°
70°
PC(H)
Swing
100% Horizontal
20°
40°
60°
* Except PK12FK3
ON/OFF
TEMP
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
RESET
SET
CLOCK
MODEL
SELECT
NOT AVAILABLE
SWING
CHECK
FAN
TEST
RUN
˚F
˚C
AMPM
STOP
START AMPM
COOL
DRY
AUTO
FAN
HEAT
1
ON/OFF –
TIMER SET
SET TEMP.
REMOTE CONTROLLER
MODE
TIMER ON/OFF CLOCK/TIMER
FAN SPEED AIR DISCHARGE
FILTER
AIR SWEEP
CHECK
TEST RUN
STAND BY
DEFROST
DRY COOL
AUTO FAN
HEAT
CENTRALLY CONTROLLED
˚F
SWING
FAN
SPEED
AUTO
RETURN
NOT AVAILABLE
˚F
CHECK MODE
FILTER
TIMER
TEST RUN
TIMER OFF
CLOCK AUTO AUTO
CHECK SET TEMP.
START STOP
B
1
2
A
ON/OFF
TEMP
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
RESET
SET
CLOCK
MODEL
SELECT
NOT AVAILABLE
SWING
CHECK
FAN
TEST
RUN
˚F
˚C
AMPM
STOP
START AMPM
COOL
DRY
AUTO
FAN
HEAT
A
2
13
ON/OFF –
TIMER SET
SET TEMP.
REMOTE CONTROLLER
MODE
TIMER ON/OFF CLOCK/TIMER
FAN SPEED AIR DISCHARGE
FILTER
AIR SWEEP
CHECK
TEST RUN
STAND BY
DEFROST
DRY COOL
AUTO FAN
HEAT
CENTRALLY CONTROLLED
˚F
SWING
FAN
SPEED
AUTO
RETURN
NOT AVAILABLE
˚F
CHECK MODE
FILTER
TIMER
TEST RUN
TIMER OFF
CLOCK AUTO AUTO
CHECK SET TEMP.
START STOP
A BC
1
2
ON/OFF
TEMP
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
RESET
SET
CLOCK
MODEL
SELECT
NOT AVAILABLE
SWING
CHECK
FAN
TEST
RUN
˚F
˚C
AMPM
STOP
START AMPM
COOL
DRY
AUTO
FAN
HEAT
C
13
A
B
2