6
Fig. 3-14
Fig. 3-15
Fig. 3-16
C
B
A
E
D
B
A
C
D
A
C
B
3.5. Mounting the indoor unit
1. Affix the mount board
to the wall.
2. Hang the indoor unit on the hook positioned on the upper part of the mount
board.
Rear, right and lower piping (Fig. 3-14)
3. While inserting the refrigerant piping and drain hose into the wall penetration
hole (penetration sleeve), hang the top of the indoor unit to the mount board
.
4. Move the indoor unit to the left and right, and verify that the indoor unit is hung
securely.
5. Fasten by pushing the bottom part of the indoor unit onto the mount board
.
(Fig. 3-15)
* Check that the knobs on the bottom of the indoor unit are securely hooked into
the mount board
.
6. After installation, be sure to check that the indoor unit is installed level.
Mount board
Indoor unit
Hook
square hole
Left and left rear piping (Fig. 3-16)
3. While inserting the drain hose into the wall penetration hole (penetration sleeve),
hang the top of the indoor unit to the mount board
.
Giving consideration to the piping storage, move the unit all the way to the left
side, then cut part of the packaging carton and wrap into a cylindrical form as
illustrated in the diagram. Hook this to the rear surface rib as a spacer, and raise
the indoor unit.
4. Connect the refrigerant piping with the site-side refrigerant piping.
5. Fasten by pushing the bottom part of the indoor unit onto the mount board
.
* Check that the knobs on the bottom of the indoor unit are securely hooked into
the mount board
.
6. After installation, be sure to check that the indoor unit is installed level.
Indoor unit
Packaging carton
Cut off
Wrap into a cylindrical form
Fasten with tape
3. Installing the indoor unit