5
DK
SW
NL
I
E
F
D
GB
RU
TR
GR
P
3. Operation
Cooling
The air conditioner works to cool the room to the selected temperature.
The fan blows air continuously at the selected speed.
Drying (dehumidifying) : Disabled in the heating
mode
The drying mode efficiently reduces the humidity in the room so that the room
temperature is not lowered excessively. When the selected room temperature is
reached in the Low setting, the airflow will stop for ten minutes and then will resume
for three minutes to keep the humidity low.
Heating
•
The air conditioner works to heat the room to the selected temperature.
•
When selecting the heating mode, a desired room temperature must be set to
avoid any cool air. The fan will gradually increase the airflow delivery up to a
selected rate.
•
When the room temperature reaches the selected temperature and the com-
pressor stops, the fan will deliver a gentle airflow.
Automatic (cooling / heating)
The air conditioner automatically goes into the cooling or heating mode to keep the
room at the selected temperature.
Ventilation
•
Ventilation will not be displayed when not available (settings cannot be speci-
fied).
•
When ventilation is selected it will operate in all modes.
Note:
The airflow settings cannot be changed on the main unit.
How to use the wireless remote controller
(option)
Replacing the Batteries and how to set the current time
[Fig. 3.0.1]
(P.2)
If no signal is transmitted and the indoor unit’s lamp does not light up even if the
remote controller is operated, the batteries may have run out, so replace them with
new ones as described below.
1
Remove the front lid.
2
Replace the batteries with alkali batteries (size AAA). Make sure that the bat-
teries are installed in the correct direction. (Insert the minus pole of the batter-
ies first.)
3
Reattach the front lid.
4
Press the RESET button using a thin stick.
5
Press the
h
and
min
button to set the current time.
6
Press the CLOCK button using a thin stick and close the front lid.
If you are not going to use the unit for a long period of time, remove the batteries to
prevent damage which may occur due to leakage of electrolyte.
Caution:
•
Signal from the WIRELESS REMOTE CONTROLLER may not be received
by the indoor unit installed in a room with fluorescent lamps using cyclic
ignition stabilizer of high voltage pulse or intermittent oscillator. If fluo-
rescent lamps are to be newly installed, consult your local dealer.
•
If other air conditioner or electric appliance are effected due to operation
of the WIRELESS REMOTE CONTROLLER or vice versa, install the air
conditioner at some distance from others or consult your dealer.
•
Install the air conditioner in a place free of dust, high temperature, vibra-
tion and shock.
•
Do not cover the REMOTE CONTROLLER.
Все каталоги и инструкции здесь:
http
:
//splitoff.ru/tehn-doc.html