- 4 -
[
III
SPECIFICATIONS ]
III
SPECIFICATIONS
[3] SPECIFICATIONS
3-1. Specifications
Model
PEFY-P20VMR-E-L/R PEFY-P25VMR-E-L/R PEFY-P32VMR-E-L/R
Cooling capacity *1
kW
2.2
2.8
3.6
Heating capacity *1
kW
2.5
3.2
4.0
Power supply voltage/frequency
Single-phase 220/230/240 V 50Hz 220/230 V 60Hz
Power consumption
Cooling
kW
0.06/0.06
0.07/0.08
Heating
kW
0.06/0.06
0.07/0.08
Current consumption
Cooling
A
0.29/0.29
0.34/0.38
Heating
A
0.29/0.29
0.34/0.38
Settable temperature
range on the remote
controller
Cooling
°C (°F)
19 to 30 (67 to 86)
Heating
°C (°F)
17 to 28 (63 to 83)
Fan
Type × Quantity
Sirocco fan × 1
External static pressure
5
Single-phase induction motor
Motor output
kW
0.018
0.023
Driving mechanism
Direct-driven
Airflow rate
(Low-Mid-High)
m
3
/min
4.8-5.8-7.9
4.8-5.8-9.3
External finish
Galvanized
External dimensions
H × W × D
Rear inlet model
mm
292 × 640 × 580
In.
11-1/2 × 25-1/4 × 22-7/8
Bottom inlet model
mm
300 × 640 × 570
In.
11-7/8 × 25-1/4 × 22-1/2
Net weight
kg
18
Wire
Min. wire size
mm (in.)
1.6 (1/8)
Breaker amperage
A
16
Refrigerant pipe
diameter
Liquid R410A
mm (in.)
ø6.35 (ø1/4) Brazed connection
Gas R410A
mm (in.)
ø12.7(ø1/2) Brazed connection
Drain pipe diameter
mm (in.)
Drain hose O.D. 26 (1-1/32)
Operating noise *2
(Low-Mid-High)
(measured in
anechoic room)
220V
dB<A>
20-25-30
20-25-33
230V
dB<A>
21-26-32
21-26-35
240V
dB<A>
22-27-30
22-27-33
Insulation material
Polyethylene foam, Urethane foam
Air filter
PP Honeycomb fabric (washable)
Refrigerant control device
LEV
Connectable outdoor unit
R410A CITY MULTI
Protection devices
Fuse
Heat exchanger
Cross fin (Aluminium fin and copper tube)
Note: *1 Maximum capacity of the unit under the following conditions
<Cooling> Indoor temperature: 27°CDB/19°CWB (81°FDB/66°FWB Outdoor temperature: 35°CDB (95°FDB)
<Heating> Indoor temperature: 20°CDB (68°FDB) Outdoor temperature: 7°CDB/6°CWB (45°FDB/43°FWB)
Pipe length: 7.5m (24-9/16ft) Height difference: 0m (0ft)
*2 Noise levels of the unit with a rear air inlet. (Noise levels are higher for the unit with a bottom air inlet.)