17
2.2. Cooling only type
Rating Conditions (ISO T1)
Indoor
Outdoor
Input (kW)
Current (A)
Current (A)
Starting current (A)
Mode
Capacity (W)
Total Input (kW) (In + Out)
Service
Ref.
Indoor unit
Outdoor unit
Cooling
7,500
3.36
0.09
0.44
15.31
85
Cooling
7,500
3.36
0.09
0.44
5.23
43
Cooling
13,000
4.90
0.26
1.24
7.22
65.5
PU-P3VGAA
1
.UK
PU-P3YGAA
1
.UK
PU-P5YGAA
1
.UK
PCA-P3HA
PCA-P5HA
Indoor
Outdoor
Input (kW)
Current (A)
Current (A)
Starting current (A)
Mode
Capacity (W)
Total Input (kW) (In + Out)
Service
Ref.
Indoor unit
Outdoor unit
Cooling
7,500
3.36
0.09
0.43
14.63
89
Cooling
7,500
3.36
0.09
0.43
4.96
45
Cooling
13,000
4.90
0.26
1.19
6.85
65.5
PU-P3VGAA
1
.UK
PU-P3YGAA
1
.UK
PU-P5YGAA
1
.UK
PCA-P3HA
PCA-P5HA
Indoor
Outdoor
Input (kW)
Current (A)
Current (A)
Starting current (A)
Mode
Capacity (W)
Total Input (kW) (In + Out)
Service
Ref.
Indoor unit
Outdoor unit
Cooling
7,500
3.36
0.09
0.41
14.02
93
Cooling
7,500
3.36
0.09
0.41
4.78
47
Cooling
13,000
4.90
0.26
1.14
6.61
65.5
PU-P3VGAA
1
.UK
PU-P3YGAA
1
.UK
PU-P5YGAA
1
.UK
PCA-P3HA
PCA-P5HA
Indoor·······220V 50Hz Single phase
Outdoor····220V 50Hz Singel phase / 380V 50Hz 3 phase
Indoor·······230V 50Hz Single phase
Outdoor····230V 50Hz Singel phase / 400V 50Hz 3 phase
Indoor·······240V 50Hz Single phase
Outdoor····240V 50Hz Singel phase / 415V 50Hz 3 phase