– 19 –
GB
6
Mode No. selection
Select the mode No. you want to set with the
B
and
C
buttons. (Only the
settable mode numbers can be selected.)
7
Select the setting contents of the selected mode.
When the
D
button is pressed, the current setting No. flashes. Use this to check the
currently set contents.
Select the setting No. using the
B
and
C
buttons.
8
The contents set at steps
3
to
7
are registered.
When the
A
button is pressed, the mode No. and setting No. flash and registration begins.
The flashing mode No. and setting No. change to a steady light and setting ends.
* When “
” flashes at the Mode No. display, communication is probably abnormal.
Make sure there are no noise sources near the transmission line.
-------------------------------------------------------------------------------------------------------------------------------------
9
To select more functions, press the
D
and repeat steps
3
to
8
.
-------------------------------------------------------------------------------------------------------------------------------------
0
End function selection.
Press and hold down the
C
and
D
buttons at the same time for two seconds or
longer.
After a while, the function selection display disappears and the remote controller returns to the air
conditioner off display.
* Do not operate the air conditioner from the remote controller for 30 seconds after the end of
function selection.
..
..
Mode No. display
Mode No. 02 = Thermistor selection
..
..
Setting No. display
Setting No. 1 =
Average temperature
reading of the indoor
units in operation
Setting No. 3 =
Built-in sensor on the
remote controller
ON
OFF
..
NOTE: When the functions of an indoor unit were changed by function selection after the end
of installation, always indicate the set contents by entering check marks or other marks