Your Mitsubishi Electric heating system products have been manufactured with high quality materials and components 

which can be recycled and/or reused. The symbol in Figure 1.1 means that electrical and electronic equipment, batter-

ies and accumulators at the end of their life, should be disposed of separately from your household waste. 

If a chemical symbol is printed beneath the symbol (Figure 1.1), this chemical symbol means that the battery or accu-

mulator contains a heavy metal at a certain concentration. This is indicated as follows;

Hg: mercury (0.0005%), Cd: cadmium (0.002%), Pb: lead (0.004%)

In the European Union there are separate collection systems for used electrical and electronic products, batteries and 

accumulators.

Please dispose of this equipment, batteries and accumulators correctly at your local community waste collection/recy-

cling centre. 

Contact your local Mitsubishi Electric dealer for country-specific details on disposal. 

Please, help us to conserve the environment we live in.

<Figure 1.1>

Disposal of the Unit

 

2

Item

Q'ty

2 zone kit

1

Flexible hose (520mm)

2

Conversion joint (

Φ

28 → G1)

2

Fixing plate

2

Gasket

4

Installation manual

1

Screw (M5×8)

2

Unit: mm

A From Cylinder unit (Hydrobox)
B To Cylinder unit (Hydrobox)

C From Zone1
D To Zone1
E From Zone2

F To Zone2

G1 connection

B

A

C D

F E

Drain socket 

(Size: Φ18.5)

B

A

C

D

F

E

Содержание PAC-TZ02-E

Страница 1: ...rk from the 2 zone kit to its disposal location Secure 2 zone kit to prevent it from falling Do not hold piping or drain socket when moving the 2 zone kit Avoid the connection of piping or drain socket from damage Otherwise it may cause water leakage To prevent incorrect installation please connect the flexible hose at the bend radius of 150 mm or more The water flow rate between the Cylinder unit...

Страница 2: ...ttery or accu mulator contains a heavy metal at a certain concentration This is indicated as follows Hg mercury 0 0005 Cd cadmium 0 002 Pb lead 0 004 In the European Union there are separate collection systems for used electrical and electronic products batteries and accumulators Please dispose of this equipment batteries and accumulators correctly at your local community waste collection recy cli...

Страница 3: ... figure 460 510 430 580 2000 2100 1220 1270 Cylinder unit Hydrobox 2 zone kit Zone1 Radiator Zone2 Floor heating Pump3 THW6 THW7 THW8 Pump2 THW9 Air vent Air vent Mixing valve 3 Unit mm Pump3 Pump2 Mixing valve Thermistor Manual air vent Cylinder unit Hydrobox Reactor box Thermistor Earth terminal ...

Страница 4: ... Do not use the flexible hose below the bend radius of 150 mm After hand tighten the nut tighten the joint 1 turn If necessary tighten by another 1 4 of a turn Pipe cover Local supply Ensure that the 2 zone kit does not touch the pressure relief valve Remove the screw from the 2 zone kit and reuse to secure ...

Страница 5: ...the back plate The back plate is provided with screw mounting holes that are round or oval To prevent the 2 zone kit from falling off the wall choose the appropriate number of holes or hole positions and horizontally secure the back plate to the appropriate wall location Plugs Local supply Wall Screws Local supply Back plate Horizontal Side view 1 5N m Back plate 5 ...

Страница 6: ... and an inside diameter of 20 mm Field supplied drain pipe VP 20A Insulated Connect drain socket to field pipeworks using suitable adhesive bond Connect the drain pipe only for Heating Cooling models Cylinder unit Hydrobox Field supplied drain pipe VP 20A Insulated Connect drain socket to field pipeworks using suitable adhesive bond Pipe cover Local supply Tightening torque 42N m Use double spanne...

Страница 7: ... 7 5 4 3 2 1 TBI 2 6 8 7 5 4 3 2 1 TBI 3 6 8 7 5 4 3 2 1 TBI 4 6 8 7 5 4 3 2 1 TBI 5 6 8 7 5 4 3 2 1 6 8 7 5 4 3 2 1 TBI 6 1 4 CN401 WH 7 2 CN22 CN108 CN01 BK 1 3 CN3C BU CNPWM WH 1 8 CN851 BK 1 5 CNRF WH CN105 RD CNIT BU 1 2 CN20 RD TBI 1 LED3 LED4 TAB1 8 1 2 3 4 5 6 1 2 3 4 5 6 7 8 CNP1 WH TBO 1 1 5 3 1 5 SW6 1 3 1 5 1 5 BU 1 LED2 1 SW1 8 1 SW2 8 1 SW3 1 SW4 6 8 1 SW5 LED1 1 3 1 3 CNP4 RD TBO 2 ...

Страница 8: ...mance view Pump key lock function Model name PAC TZ02 E Dimension 265mm 383mm 383mm Weight 17kg Power supply 230V single phase 50Hz from Cylinder unit Hydrobox Sound pressure level 28dB A Sound power level 40dB A Pump2 3 Max 52W 0 52A Max head 7 0m 1 Mixing valve 5W Running time 90 120s Water flow rate range Depend on outdoor unit Note Max flow rate is 36 9L min If the flow rate exceeds 36 9L min ...

Страница 9: ...proportional pressure curve PP2 intermediate proportional pressure curve PP3 highest proportional pressure curve PP Auto Adapt highest to lowest proportional pressure curve The Auto Adapt function enables the circulator to adjust the pump performance automatically to the size of the system or the variations in load over time Mode LED1 green LED2 yellow LED3 yellow LED4 yellow LED5 yellow PP1 PP2 P...

Страница 10: ...ressure curve The Auto Adapt function enables the circulator to adjust the pump performance automatically to the size of the system or the variations in load over time The circulator runs on a constant curve Constant Pressure CP1 CP2 CP3 0 0 1 0 2 0 4 0 5 70 60 30 Flow rate L min 0 10 20 30 40 50 60 70 80 External static pressure kPa 0 10 20 30 40 50 60 70 80 0 0 1 0 2 0 4 0 5 60 External static p...

Страница 11: ...11 ...

Страница 12: ...FFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Printed in the UNITED KINGDOM Please be sure to put the contact address telephone number on this manual before handing it to the customer ...

Отзывы: