47
CHAPTER 3 SPECIFICATIONS
3
3.
6
List
s of
R
e
mot
e
Reg
is
ter
Ar
eas
*1
Available only under the heating-cooling control (expanded mode). For details on the expanded mode, refer to the
following.
*2
Available only under the mix control (expanded mode). For details on the expanded mode, refer to the following.
(2) List of remote register (RWw) areas
RWr13
Use prohibited
CH4 Manipulated value (MV)
CH4 Manipulated value for
heating (MVh)
CH4 Manipulated value (MV)
RWr14
Use prohibited
CH1 Self-tuning flag
CH1 Manipulated value for
cooling (MVc)
CH1 Manipulated value for
cooling (MVc)
RWr15
Use prohibited
CH2 Self-tuning flag
CH2 Manipulated value for
cooling (MVc)
CH2 Manipulated value for
cooling (MVc)
RWr16
Use prohibited
CH3 Self-tuning flag
CH3 Manipulated value for
cooling (MVc)
CH3 Self-tuning flag
RWr17
Use prohibited
CH4 Self-tuning flag
CH4 Manipulated value for
cooling (MVc)
CH4 Self-tuning flag
RWr18
Use prohibited
CH1 Manipulated value (MV)
for output with another analog
module
CH1 Manipulated value of
heating (MVh) for output with
another analog module
CH1 Manipulated value of
heating (MVh) for output with
another analog module
RWr19
Use prohibited
CH2 Manipulated value (MV)
for output with another analog
module
CH2 Manipulated value of
heating (MVh) for output with
another analog module
CH2 Manipulated value of
heating (MVh) for output with
another analog module
RWr1A
Use prohibited
CH3 Manipulated value (MV)
for output with another analog
module
CH3 Manipulated value of
heating (MVh) for output with
another analog module
CH3 Manipulated value (MV)
for output with another analog
module
RWr1B
Use prohibited
CH4 Manipulated value (MV)
for output with another analog
module
CH4 Manipulated value of
heating (MVh) for output with
another analog module
CH4 Manipulated value (MV)
for output with another analog
module
RWr1C
Use prohibited
Use prohibited
CH1 Manipulated value of
cooling (MVc) for output with
another analog module
CH1 Manipulated value of
cooling (MVc) for output with
another analog module
RWr1D
Use prohibited
Use prohibited
CH2 Manipulated value of
cooling (MVc) for output with
another analog module
CH2 Manipulated value of
cooling (MVc) for output with
another analog module
RWr1E
Use prohibited
Use prohibited
CH3 Manipulated value of
cooling (MVc) for output with
another analog module
Use prohibited
RWr1F
Use prohibited
Use prohibited
CH4 Manipulated value of
cooling (MVc) for output with
another analog module
Use prohibited
Remote register (RWw)
Signal direction: Master/local module
Temperature control module
Device number
Temperature input
Standard control
Heating-cooling control
Mix control
RWw0
Use prohibited
CH1 Temperature process
value for input with another
analog module (PV)
CH1 Temperature process
value for input with another
analog module (PV)
CH1 Temperature process
value for input with another
analog module (PV)
RWw1
Use prohibited
CH2 Temperature process
value for input with another
analog module (PV)
CH2 Temperature process
value for input with another
analog module (PV)
CH2 Temperature process
value for input with another
analog module (PV)
RWw2
Use prohibited
CH3 Temperature process
value for input with another
analog module (PV)
CH3 Temperature process
value for input with another
analog module (PV)
CH3 Temperature process
value for input with another
analog module (PV)
Remote register (RWr)
Signal direction: Temperature control module
Master/local module
Device number
Temperature input
Standard control
Heating-cooling control
Mix control
Содержание NZ2GF2B-60TCRT4
Страница 1: ...CC Link IE Field Network Temperature Control Module User s Manual NZ2GF2B 60TCTT4 NZ2GF2B 60TCRT4 ...
Страница 2: ......
Страница 86: ...84 Memo ...
Страница 233: ...231 CHAPTER 8 FUNCTIONS 8 8 4 CC Link IE Field Network Function 3 Click the OK button on the following window ...
Страница 268: ...266 Memo ...
Страница 377: ...375 APPENDICES A Appendix 6 External Dimensions Memo ...
Страница 383: ...I 4 4 7 8 381 Memo ...
Страница 387: ......