257
CHAPTER 9 PROGRAMMING
9
9.
3 Pr
ogram Ex
amples
Set the initial values for the parameters other than the above.
*1
Configure this setting only when the peak current suppression function is used.
*2
Configure this setting only when the simultaneous temperature rise function is used.
(4) Device for user
CH2 Simultaneous temperature rise
function setting
CH2 Simultaneous temperature rise group setting
1: Group 1
CH2 Simultaneous temperature rise AT mode selection
1: AT for simultaneous
temperature rise
CH3 Simultaneous temperature rise
function setting
CH3 Simultaneous temperature rise group setting
2: Group 2
CH3 Simultaneous temperature rise AT mode selection
1: AT for simultaneous
temperature rise
CH4 Simultaneous temperature rise
function setting
CH4 Simultaneous temperature rise group setting
2: Group 2
CH4 Simultaneous temperature rise AT mode selection
1: AT for simultaneous
temperature rise
Device
Description
X20
Error reset signal
QX10 (X20 to X2F)
X21
CH1 Operation request instruction
X22
CH2 Operation request instruction
X23
CH3 Operation request instruction
X24
CH4 Operation request instruction
X30
Auto tuning execute instruction
QX10 (X30 to X3F)
X100A
Error flag
NZ2GF2B-60TCTT4 (X1000 to X103F)
X100B
Remote READY
X1011
CH1 Operation monitor
X1012
CH2 Operation monitor
X1013
CH3 Operation monitor
X1014
CH4 Operation monitor
X1015
Back-up of the set value completion flag
X1020
CH1 Auto tuning status
X1021
CH2 Auto tuning status
X1022
CH3 Auto tuning status
X1023
CH4 Auto tuning status
Y1009
Initial data setting request flag
NZ2GF2B-60TCTT4 (Y1000 to Y103F)
Y100A
Error clear request flag
Y1010
During operation setting change instruction
Y1011
CH1 Operation request flag
Y1012
CH2 Operation request flag
Y1013
CH3 Operation request flag
Y1014
CH4 Operation request flag
Y1015
Set value backup instruction
Y1018
CH1 Stop request flag
Y1019
CH2 Stop request flag
Y101A
CH3 Stop request flag
Y101B
CH4 Stop request flag
Y1020
CH1 Auto tuning instruction
Y1021
CH2 Auto tuning instruction
Y1022
CH3 Auto tuning instruction
Y1023
CH4 Auto tuning instruction
D2000
Latest error code
D2001
Error occurrence address
D2004
CH1 Alert definition
D2005
CH2 Alert definition
Setting item
Set value
Содержание NZ2GF2B-60TCRT4
Страница 1: ...CC Link IE Field Network Temperature Control Module User s Manual NZ2GF2B 60TCTT4 NZ2GF2B 60TCRT4 ...
Страница 2: ......
Страница 86: ...84 Memo ...
Страница 233: ...231 CHAPTER 8 FUNCTIONS 8 8 4 CC Link IE Field Network Function 3 Click the OK button on the following window ...
Страница 268: ...266 Memo ...
Страница 377: ...375 APPENDICES A Appendix 6 External Dimensions Memo ...
Страница 383: ...I 4 4 7 8 381 Memo ...
Страница 387: ......