1. Safety Precautions .................................................................2
2. Parts Names ...........................................................................2
3. Operation ................................................................................3
4. Timer.......................................................................................4

5. Care and Cleaning..................................................................4
6. Trouble Shooting ....................................................................5
7. Speci

¿

 cations .........................................................................6

Ź

  Before installing the unit, make sure you read all the “Safety 

Precautions”.

Ź

  The “Safety Precautions” provide very important points regard-

ing safety. Make sure you follow them.

Ź

  Please report to or take consent by the supply authority before 

connection to the system.

1. Safety Precautions

2. Parts Names

Ŷ

 Indoor Unit

   

 

 

MVZ-A·AA4

Fan steps

3 steps

Vane

 –

Louver

Filter

Normal

Filter cleaning indication

Symbols used in the text

 Warning:

Describes precautions that should be observed to prevent danger of 
injury or death to the user.

 Caution:

Describes precautions that should be observed to prevent damage 
to the unit.

Symbols used in the illustrations

  : Indicates a part which must be grounded.

 Warning:

•  The unit must not be installed by the user. Ask the dealer or an 

authorized company to install the unit. If the unit is installed im-
properly, water leakage, electric shock or 

¿

 re may result.

•  Do not stand on, or place any items on the unit. 
•  Do not splash water over the unit and do not touch the unit with 

wet hands. An electric shock may result.

•  Do not spray combustible gas close to the unit. Fire may result.
•  Do not place a gas heater or any other open-

À

 ame appliance where 

it will be exposed to the air discharged from the unit. Incomplete 
combustion may result.

•  Do not remove the front panel or the fan guard from the outdoor 

unit when it is running. 

•  When you notice exceptionally abnormal noise or vibration, stop 

operation, turn off the power switch, and contact your dealer.

• Never insert 

¿

 ngers, sticks etc. into the intakes or outlets.

•  If you detect odd smells, stop using the unit, turn off the power 

switch and consult your dealer. Otherwise, a breakdown, electric 
shock or 

¿

 re may result.

•  This air conditioner is NOT intended for use by children or in

¿

 rm 

persons without supervision.

•  Young children must be supervised to ensure that they do not play 

with the air conditioner.

•  If the refrigeration gas blows out or leaks, stop the operation of the air 

conditioner, thoroughly ventilate the room, and contact your dealer. 

 Caution:

•  Do not use any sharp object to push the buttons, as this may dam-

age the remote controller.

•  Never block or cover the indoor or outdoor unit’s intakes or outlets. 

Disposing of the unit

When you need to dispose of the unit, consult your dealer.

Ŷ

 

MVZ-A·AA4

Multi Position

Air Outlet

Air Inlet

Filter

Door

Содержание MVZ-A12 AA4

Страница 1: ...ease read this operation manual thoroughly before operating the air conditioner unit English FOR USER M SERIES MANUEL D UTILISATION Pour une utilisation correcte sans risques veuillez lire le manuel d utilisation en entier avant de vous servir du climatiseur Français POUR L UTILISATEUR ...

Страница 2: ...unit with wet hands An electric shock may result Do not spray combustible gas close to the unit Fire may result Do not place a gas heater or any other open Àame appliance where it will be exposed to the air discharged from the unit Incomplete combustion may result Do not remove the front panel or the fan guard from the outdoor unit when it is running When you notice exceptionally abnormal noise or...

Страница 3: ...s the air conditioner switches to heating mode Cooling mode 15 minutes switches from heating to cooling Set temperature 4 F 2 C Set temperature Set temperature 4 F 2 C 15 minutes switches from cooling to heating 3 2 Fan speed setting Note Ɣ In the following cases the actual fan speed generated by the unit will differ from the speed shown the remote controller display 1 When the unit is in STAND BY...

Страница 4: ...fore you start cleaning stop operation and turn OFF the power supply Indoor units are equipped with lters to remove the dust of sucked in air Clean the lters using the methods shown in the following sketches ŹFilter removal Caution In removing the lter precautions must be taken to protect your eyes from dust Also if you have to climb up on a stool to do the job be careful not to fall When the filt...

Страница 5: ...n the wired remote controller display appears in the wired remote controller display 1 Ŷ During central control appears in the wired remote controller display and air conditioner operation cannot be started or stopped using the wired remote controller When restarting the air conditioner soon after stopping it it does not operate even though the ON OFF button is pressed Ŷ Wait approximately three m...

Страница 6: ...tion examples Broadcasting studio music room etc Reception room hotel lobby etc Of ce hotel room Noise levels 3 to 7 dB 6 to 10 dB 9 to 13 dB Nothing appears in the wireless remote controller display the display is faint or signals are not received by the indoor unit Ŷ The batteries are low Replace the batteries and press the Reset button Ŷ If nothing appears even after the batteries are replaced ...

Страница 7: ... de provoquer une électrocution Ne vaporisez pas de gaz inÀammable à proximité de l appareil Cela risquerait de provoquer un incendie Ne placez pas un chauffage au gaz ou tout autre appareil fonctionnant avec une Àamme nue là où il serait exposé à l échappement d air du climatiseur Cela risquerait de provoquer une mauvaise combustion Ne retirez pas la face avant ou la protection du ventilateur de ...

Страница 8: ...s de la température dé nie pendant 15 minutes Mode de refroidissement 15 minutes passage du mode de chauffage au mode de refroidissement Température dé nie 4 F 2 C Température dé nie Température dé nie 4 F 2 C 15 minutes passage du mode de re froidissement au mode de chauffage 3 2 Réglage de la vitesse du ventilateur Remarque Ɣ Dans les cas suivants la vitesse du ventilateur actuelle générée par l...

Страница 9: ...on Avant de commencer le nettoyage arrêtez l appareil et coupez l alimentation Les appareils intérieurs sont équipés de ltres servant à extraire les poussières de l air aspiré Nettoyez les ltres selon les méthodes illustrées ci après ŹRetrait du ltre Précaution Lors du retrait du ltre protégez vos yeux de la poussière Si vous devez monter sur un tabouret pour effectuer l opération faites attention...

Страница 10: ...nce câblée 1 Ŷ Lors du contrôle centralisé le signe s af che sur l écran de la com mande à distance câblée et le fonctionnement du climatiseur ne peut pas être activé ou désactivé à l aide de la commande à distance câblée Lorsque le climatiseur est redémarré immédiatement après avoir été éteint son fonctionnement est bloqué même si la touche ON OFF Marche Arrêt est sollicitée Ŷ Patientez trois min...

Страница 11: ...phonique faible Exemples de pièce Studio de radio diffusion salle de musique etc Salle de ré ception entrée d hôtel etc Bureau chambre d hôtel Niveaux sonores 3 à 7 dB 6 à 10 dB 9 à 13 dB Rien ne s af che sur l écran de la télécommande sans l l af chage est faible ou l appareil intérieur ne reçoit pas les signaux Ŷ Les piles sont faibles Remplacez les piles et appuyez sur la touche Reset Réinitial...

Страница 12: ...U TOKYO 100 8310 JAPAN PA79D203H03 Please be sure to put the contact address telephone number on this manual before handing it to the customer This product is designed and intended for use in the residential commercial and light industrial environment ...

Отзывы: