12
MUZ-FS06NA MUZ-FS06NAH MUZ-FS09NA MUZ-FS09NAH MUZ-FS12NA MUZ-FS12NAH
MUZ-FS15NA MUZ-FS15NAH MUZ-FS18NA MUZ-FS18NAH
7-1. PERFORMANCE DATA
1) COOLING CAPACITY
Model
Indoor air
Outdoor intake air DB temperature (˚F)
IWB (˚F)
75
85
95
TC SHC SHF TPC TC SHC SHF TPC TC SHC SHF TPC
MUZ-FS06NA
MUZ-FS06NAH
71
7.4
6.1
0.83 0.28
6.9
5.7
0.83 0.31
6.5
5.3
0.83 0.33
67
7.0
6.7
0.96 0.26
6.5
6.2
0.96 0.29
6.0
5.8
0.96 0.32
63
6.5
7.2
1.09 0.25
6.1
6.6
1.09 0.28
5.6
6.2
1.09 0.30
MUZ-FS09NA
MUZ-FS09NAH
71
11.0
8.7
0.79 0.50 10.3
8.1
0.79 0.55
9.7
7.6
0.79 0.59
67
10.4
9.6
0.92 0.47
9.7
8.9
0.92 0.52
9.0
8.3
0.92 0.56
63
9.8
10.3 1.05 0.45
9.1
9.6
1.05 0.50
8.5
8.9
1.05 0.53
MUZ-FS12NA
MUZ-FS12NAH
71
14.7 10.2 0.70 0.77 13.7
9.6
0.70 0.85 12.9
9.0
0.70 0.91
67
13.9
11.6
0.83 0.73 13.0 10.8 0.83 0.80 12.0 10.0 0.83 0.87
63
13.1 12.6 0.96 0.70 12.1
11.7
0.96 0.77
11.3
10.9 0.96 0.83
MUZ-FS15NA
MUZ-FS15NAH
71
17.2
9.7
0.57 0.89 16.0
9.1
0.57 0.98 15.1
8.5
0.57 1.05
67
16.2
11.4
0.70 0.84 15.1 10.6 0.70 0.93 14.0
9.8
0.70 1.00
63
15.3 12.7 0.83 0.80 14.1
11.8
0.83 0.89 13.2
11.0
0.83 0.96
MUZ-FS18NA
MUZ-FS18NAH
71
21.1
11.3
0.54 1.22 19.7 10.6 0.54 1.34 18.5
9.9
0.54 1.44
67
20.0 13.4 0.67 1.16 18.6 12.4 0.67 1.27 17.2
11.5
0.67 1.38
63
18.7 15.1 0.80 1.10 17.4 14.0 0.80 1.22 16.2 13.0 0.80 1.31
Model
Indoor air
Outdoor intake air DB temperature (˚F)
IWB (˚F)
105
115
TC SHC SHF TPC TC SHC SHF TPC
MUZ-FS06NA
MUZ-FS06NAH
71
6.0
5.0
0.83 0.35
5.5
4.6
0.83 0.36
67
5.6
5.4
0.96 0.33
5.1
4.9
0.96 0.35
63
5.1
5.6
1.09 0.32
4.7
5.1
1.09 0.33
MUZ-FS09NA
MUZ-FS09NAH
71
9.0
7.1
0.79 0.62
8.3
6.5
0.79 0.64
67
8.4
7.7
0.92 0.59
7.7
7.1
0.92 0.62
63
7.7
8.1
1.05 0.57
7.0
7.4
1.05 0.59
MUZ-FS12NA
MUZ-FS12NAH
71
12.0
8.4
0.70 0.96
11.0
7.7
0.70 1.00
67
11.2
9.3
0.83 0.92 10.3
8.5
0.83 0.97
63
10.3
9.9
0.96 0.89
9.4
9.0
0.96 0.92
MUZ-FS15NA
MUZ-FS15NAH
71
14.0
7.9
0.57
1.11
12.9
7.3
0.57 1.15
67
13.0
9.1
0.70 1.06 12.0
8.4
0.70
1.11
63
12.0 10.0 0.83 1.02 10.9
9.1
0.83 1.06
MUZ-FS18NA
MUZ-FS18NAH
71
17.2
9.2
0.54 1.52 15.8
8.5
0.54 1.58
67
16.0 10.7 0.67 1.46 14.7
9.9
0.67 1.53
63
14.7
11.8
0.80 1.40 13.4 10.8 0.80 1.46
NOTE
:
1. IWB : Intake air wet-bulb temperature
TC : Total Capacity (x10
3
Btu/h)
SHC : Sensible Heat Capacity (x10
3
Btu/h) SHF : Sensible Heat Factor
TPC : Total Power Consumption (kW)
2. SHC is based on 80˚F of indoor Intake air DB temperature.
DATA
7
OBH873