AUTO RESTART FUNCTION

• These models are equipped with an auto restart function. If you do not want to use this function, please

consult the service representative because the setting of the unit needs to be changed.

• When the indoor unit is controlled with the remote controller, the operation mode, the set temperature, and

the fan speed are memorized by the indoor electronic control P.C. board. The auto restart function sets to
work the moment the power has restored after power failure, then, the unit will restart automatically. If the unit
is operated in “I FEEL...” or “AUTO” mode before power failure, the operation mode (COOL, DRY or HEAT) is
not stored in the memory. When the main power is turned on, the unit decides the operation mode by the
initial room temperature at restart and starts operation again.

Operation

1

If the main power has been cut, the operation settings remain.

2

When three minutes have passed after power was restored, the unit will restart automatically according to
the memory.

Notes:
• The operation settings are memorized when 10 seconds have passed after the remote controller was oper-

ated.

• If the main power is turned off or a power failure occurs while AUTO START/STOP timer is active, the timer

setting is cancelled. As these models are equipped with an auto restart function, the air conditioner starts
operating with timer cancelled at the same time that power is restored.

• If the unit has been off with the remote controller before power failure, the auto restart function does not work

as the power button of the remote controller is off.

• To prevent breaker off due to the rush of starting current, systematize other home appliances not to turn on

at the same time.

6-7

EXPLANATION TO THE  CUSTOMER

• Using the instruction manual, explain the following to the customer how to control temperature, how to re-

move the air filters, how to remove or put the remote controller in the remote controller holder, how to clean,
precautions, etc.

• Recommend the customer to carefully read the Operating Instruction Book.

EMERGENCY OPERATION switch

6-5

TEST RUN

• Before performing the test run, recheck for any wrong wiring.

Wrong wiring prevents normal operation or results in blown fuse disabling operation.

• The test run can be initiated by using EMERGENCY OPERATION switch (press button switch). The EMER-

GENCY OPERATION switch is pressed, the unit will start the test run (continuous operation) for 30 minutes
in COOL MODE or HEAT MODE, depending on which mode is selected. During this 30 minutes a thermostat
does not work. After 30 minutes the unit will start the EMERGENCY OPERATION at fixed temperature
setting of 24

°

C in COOL MODE or HEAT MODE.

• Perform test run in the following procedure.

PROCEDURE

• Press the EMERGENCY OPERATION switch.

1

Press it once, and the EMERGENCY COOL
MODE starts.

If the left side lamp of the operation indicator blinks
every 0.5 seconds, inspect the in/out connecting wire

B

 for mis-wiring.

2

Press it once more, and the EMERGENCY HEAT
MODE starts.

3

Press it once more, and the operation stops.

(The operation mode changes in order of 

1

 - 

3

every press of the EMERGENCY OPERATION
switch.)

Checking the remote (infrared) signal reception

Press the ON/OFF button on the remote control and check that an electronic sound is heard from the indoor
unit. Press the ON/OFF button again to turn the air conditioner off.

If the indoor unit is operated with the remote control, both the trial and emergency operations are released
by commands from the remote control.

• Once the compressor stops, the restart preventive device operates so the compressor will not operate for 3

minutes to protect the air conditioner.

POWER

3

Mode

COOL

(Light)

(Off)

Operation indicator

lamp

STOP

(Lights not turn on)

HEAT

(Off)

(Light)

2

1

Содержание MUZ-A12YV

Страница 1: ...TALLATION LOCATION 2 3 INSTALLATION DIAGRAM ACCESSORIES 3 4 INDOOR UNIT INSTALLATION 4 5 OUTDOOR UNIT INSTALLATION 9 6 INDOOR OUTDOOR UNIT CONNECTION FINISHING AND TEST RUN 10 7 FOR MOVEMENT AND MAINTENANCE 13 Floor and CeilingType Air Conditioner MCFZ A12WV MUZ A12YV H FLARE CONNECTION TYPE English HFC utilized R410A ...

Страница 2: ...tion of the air conditioner may interfere with radio or TV reception in areas where reception is weak An amplifier may be required for the affected device In a place as far away as possible from fluorescent and incandescent lights so the infrared remote control can operate the air conditioner normally Where the air filter can be removed and replaced easily 2 2 WIRELESS REMOTE CONTROLLER MOUNTING P...

Страница 3: ...o 5 F Fixing screw for E The quantity depends on the pipe length 2 to 5 G Drain joint pipe PVC pipe OD ø26 L 50 mm 1 H Power supply cord 3 core 1 0 mm2 1 I Piping hole repair parts Putty and Wall hole cover 1 J Installation plate fixing bolt M10 4 K Nut Spring washer for J M10 4 set REFRIGERANT AND DRAIN PIPE SIZES Refrigerant pipe Liquid OD ø6 35 Gas OD ø9 52 Drain pipe Hard PVC pipe OD ø26 OPTIO...

Страница 4: ...may cause dew drippage 4 1 A CASE OF SUSPENDING INDOOR UNIT FROM THE CEILING 4 1 1 MOUNTING INSTALLATION PLATE FIXING BOLTS 4 INDOOR UNIT INSTALLATION 1 Determine the locations of installation plate fixing bolts Use installation pattern to determine the locations of instal lation plate fixing bolts J a Installation pattern Details are printed on pattern Attention Surrounding temperature and humidi...

Страница 5: ...wn in Fig 2 Be sure to confirm letters FRONT in installation plates 1 set FRONT side to air outlet side of indoor unit a FRONT 1 Installation plate 2 In case of fixing installation plates 1 above the ceiling put installation plates fixing bolt through a nut a spring washer the installation plate a spring washer and double nut Fig 3 In case of fixing installation plates 1 forward the ceiling direct...

Страница 6: ...irm the dimensions as below 4 2 4 FRONT GRILLE REMOVAL See to 4 1 4 Page 5 4 2 5 OPENING KNOCKOUT HOLE See to 4 1 5 Page 5 Installation pattern Remove installation pattern after installing Horizontal base line Hole for refrigerant and drain pipe in the case of downward piping Hole for refrigerant and drain pipe in the case of rear piping Installation plate 1 FRONT 4 2 6 FIXING UNIT TO INSTALLATION...

Страница 7: ...e to fix the cable by cable clamp 3 Replace the terminal cover securely Cable clamp Screw Terminal cover Warning Attach the electrical part cover securely If it is attached incorrectly it could result in a fire an elec tric shock due to dust water etc Use the specified indoor outdoor unit connecting wire to connect the indoor and outdoor units and fix the wire to the terminal block securely so tha...

Страница 8: ...rain pipe cover D Drain pipe VP 20 c 8 D b a d b a 30 2 In case of connecting drain pipe D to drain joint bush through drain hose Drain hose 7 which is contained in accessories is flexible so use it when drain pipe D should be alternated direction Be sure to wind pipe cover which is provided in accessories around drain hose with vinyl tape Cut VP 20 in dimension as shown at the right and connect d...

Страница 9: ...en the terminal screws to prevent them from loosening After tightening pull the wires lightly to confirm that they do not move Warning Be sure to attach the service panel of the outdoor unit securely If it is not attached correctly it could result in a fire or an electric shock due to dust water etc Indoor terminal block Outdoor terminal block N 3 2 3 N 2 Indoor outdoor unit connecting wire B 4 co...

Страница 10: ...e for R410A Yes Substitutable for R410A Electronic scale for re frigerant charging 6 2 FLARING WORK Main cause of gas leakage is defect in flaring work Carry out correct flaring work in the following procedure 2 Burrs removal Completely remove all burrs from the cut cross section of pipe Put the end of the copper pipe to downward direction as you remove burrs in order to avoid to let burrs drop in...

Страница 11: ...nd the gas pipe between the indoor and the outdoor unit Remove the service port cap of the stop valve on the side of the outdoor unit gas pipe The stop valve will not work in it initial state fresh out of the factory totally closed with cap on Connect the gauge manifold valve and the vacuum pump to the service port of the stop valve on the gas pipe side of the outdoor unit Run the vacuum pump Vacu...

Страница 12: ...in the following to the customer how to control temperature how to re move the air filters how to remove or put the remote controller in the remote controller holder how to clean precautions etc Recommend the customer to carefully read the Operating Instruction Book EMERGENCY OPERATION switch 6 5 TEST RUN Before performing the test run recheck for any wrong wiring Wrong wiring prevents normal oper...

Страница 13: ...arge refrigerant into the atmosphere during installation reinstallation or re pairs to the refrigerant circuit For additional charging charge the refrigerant from liquid phase of the gas cylinder If the refrigerant is charged from the gas phase composition change may occur in the refrigerant inside the cylinder and the outdoor unit In this case ability of the refrigerating cycle decreases or norma...

Страница 14: ... TOKYO 100 8310 JAPAN This product is designed and intended for use in the residential commercial and light industrial environment The product at hand is based on the following EU regulations Low Voltage Directive 73 23 EEC Electromagnetic Compatibility Directive 89 336 EEC ...

Отзывы: