9-2. R.V. COIL CONTROL
Heating . . . . . . . . . . . . . . . . . ON
Cooling . . . . . . . . . . . . . . . . . OFF
Dry . . . . . . . . . . . . . . . . . . . . OFF
NOTE:
The 4-way valve reverses for 5 seconds right before start-up of the compressor.
ON
OFF
ON
OFF
Outdoor fan
motor
Compressor
5 seconds
15 seconds
ON
OFF
Compressor
Outdoor fan
motor
R.V.coil
ON
OFF
ON
OFF
<COOL>
5 seconds
<HEAT>
5 seconds
9-1. OUTDOOR FAN MOTOR CONTROL
The fan motor turns ON/OFF, interlocking with the compressor.
[ON] The fan motor turns ON 5 seconds before the compressor starts up.
[OFF] The fan motor turns OFF 15 seconds after the compressor has stopped running.
9-3. RELATION BETWEEN MAIN SENSOR AND ACTUATOR
Sensor
Purpose
Actuator
Compressor
LEV
Outdoor fan
motor
R.V.coil
Indoor fan
motor
Defrost
heater
Discharge temperature
thermistor
Protection
○
○
Indoor coil temperature
thermistor
Cooling: Coil frost prevention
○
Heating: High pressure protec-
tion
○
○
Defrost thermistor
Heating: Defrosting
○
○
○
○
○
Fin temperature thermistor
Protection
○
○
Ambient temperature
thermistor
Cooling: Low ambient tempera-
ture operation
○
○
○
Heating: Defrosting (Heater)
○
Outdoor heat exchanger tem-
perature thermistor
Cooling: Low ambient tempera-
ture operation
○
○
○
Cooling: High pressure protec-
tion
○
○
○
ACTUATOR CONTROL
9
OBH668E
Содержание MUFZ-KJ25VEHZ
Страница 8: ...8 WIRING DIAGRAM 6 MUFZ KJ25VEHZ E1 ER1 ET1 MUFZ KJ35VEHZ E1 ER1 ET1 OBH668E ...
Страница 9: ...9 MUFZ KJ25VEHZ E2 ER2 ET2 MUFZ KJ35VEHZ E2 ER2 ET2 OBH668E ...
Страница 10: ...10 MUFZ KJ50VEHZ E1 ER1 ET1 OBH668E ...
Страница 11: ...11 MUFZ KJ50VEHZ E2 ER2 ET2 OBH668E ...
Страница 49: ...49 2 Relay P C board MUFZ KJ50VEHZ To inverter P C board CN681 CN680 CN60 L68B L68A 10 VDC OBH668E ...