MICROPROCESSOR CONTROL
32
WIRELESS REMOTE CONTROLLER
Once the operation mode are set, the same operation mode
can be repeated by simply turning the
OPERATE/STOP(ON/OFF) button ON.
Indoor unit receives the signal with a beep tone.
When the system turns off, 3-minute time delay will operate
to protect system from overload and compressor will not
restart for 3 minutes.
9-1. “I FEEL CONTROL” (
) OPERATION
(1) Press OPERATE/STOP(ON/OFF) button on the
remote controller. OPERATION INDICATOR lamp of
the indoor unit turns on with a beep tone.
(2) Select “I FEEL CONTROL”
(
)
mode with the
OPERATION SELECT button.
(3) The operation mode is determined by the room tem-
perature at start-up of the operation.
ON/OFF
FAN
TOO
WARM
TOO
COOL
VANE
MODE
STOP
START
HR.
MIN.
I FEEL COOL
HEAT DRY
RESET CLOCK
OPERATION SELECT button
FAN SPEED CONTROL button
OFF-TIMER button
HR. button
MIN. button
(TIME SET button)
ON-TIMER button
RESET button
VANE CONTROL button
CLOCK SET button
ON/OFF
TOO
COOL
PM
AM
TOO
WARM
Signal transmitting section
Operation display section
OPERATE /STOP
(ON /OFF)button
TEMPERATURE buttons
Example
Previous operation
COOL mode of
“I FEEL CONTROL”
or COOL mode
●
Once the mode is fixed, the mode does not change by
room temperature afterwards.
●
Under the ON-TIMER (
) operation, mode is
determined according to the room temperature at set
time the operation starts.
●
When the system is stopped with the
OPERATE/ STOP(ON/OFF) button on the remote con-
troller, and restarted within 2 hours in “I FEEL CON-
TROL”
(
)
mode, the system operates in previous
mode automatically regardless of the room tempera-
ture.
Example
Previous operation
COOL mode of
“I FEEL CONTROL”
or COOL mode
When the system is restarted after 2 hours and more,
the operation mode is determined by the room temper-
ature at start-up of the operation.
Restart
COOL mode of
“I FEEL CONTROL”
Restart
COOL or DRY or
HEAT mode of “I
FEEL CONTROL” that
is determined by room
temperature at start-up
of the operation.
lighted
not lighted
Approx. 2
:
or more
Difference
between target
temperature
and room
temperature
Approx. 2
:
or less
This shows that the
air conditioner is
operating to reach
the target temperature.
Please wait until the
target temperature is
obtained.
This shows that the
room temperature is
approaching the
target temperature.
Operation state
Indication
Operation Indicator
Operation Indicator lamp
The operation indicator at the right side of the indoor
unit indicates the operation state.
INDOOR UNIT DISPLAY SECTION
• The following indication applies regardless of shape of
the indicator.
MCFH-13NV -
MCFH-24NV -
MCFH-18NV -
E3
E3
E4
Mode
COOL mode of
"I FEEL CONTROL"
DRY mode of
"I FEEL CONTROL"
HEAT mode of
"I FEEL CONTROL"
Initial room temperature
25
:
or more
23
:
to 25
:
less than 23
:
MUCFH-13NV -
MUCFH-18NV -
MUCFH-18NV -
MUCFH-24NV -
E3
E3
E4
E4