TEST RUN

• Before performing the test run, recheck for any wrong wiring.

Wrong wiring prevents normal operation or results in blown fuse disabling operation.

• The test run can be initiated by using EMERGENCY OPERATION switch (press button switch). The EMER-

GENCY OPERATION switch is pressed, the unit will start the test run (continuous operation) for 30 minutes
in COOL MODE or HEAT MODE, depending on which mode is selected. During this 30 minutes a thermostat
does not work. After 30 minutes the unit will start the EMERGENCY OPERATION at fixed temperature
setting of 24

°

C in COOL MODE or HEAT MODE.

• Perform test run in the following procedure.

PROCEDURE

<MCF-13/18/24NV>

• Press the EMERGENCY OPERATION switch.

1

Press it once, and the EMERGENCY COOL
MODE starts.

2

Press it once more, and the operation stops.

(The operation mode changes 

1

 and 

2

 by turns

every press of the EMERGENCY OPERATION
switch.)

<MCFH-13/18NV>

• Press the EMERGENCY OPERATION switch.

1

Press it once, and the EMERGENCY COOL
MODE starts.

If the left side lamp of the operation indicator blinks
every 0.5 seconds, inspect the in/out connecting wire

A

 for mis-wiring.

2

Press it once more, and the EMERGENCY HEAT
MODE starts.

3

Press it once more, and the operation stops.

(The operation mode changes in order of 

1

 - 

3

every press of the EMERGENCY OPERATION
switch.)

Checking the remote (infrared) signal reception

Press the ON/OFF button on the remote control and check that an electronic sound is heard from the indoor
unit. Press the ON/OFF button again to turn the air conditioner off.

If the indoor unit is operated with the remote control, both the trial and emergency operations are released
by commands from the remote control.

• Once the compressor stops, the restart preventive device operates so the compressor will not operate for 3

minutes to protect the air conditioner.

EMERGENCY OPERATION switch

6-3

PURGING PROCEDURES · LEAK TEST

PURGING PROCEDURES

Connect the refrigerant pipes (both the liquid pipe and the gas pipe) between the indoor and the outdoor
unit.

Remove the service port cap of the stop valve on the gas pipe side of the outdoor unit.
(The stop valve will not work in it initial state fresh out of the factory (totally closed with cap on).)

Connect the gauge manifold valve and the vacuum pump to the service port of the stop valve on the gas
pipe side of the outdoor unit.

Run the vacuum pump. (Vacuumize for more than 15 minutes.)

Check the vacuum with the gauge manifold valve, then close the gauge manifold valve and stop the vacuum
pump.

Leave as it is for one or two minutes. Make sure the pointer gauge manifold valve remains in the same
position. Confirm that the pressure gauge shows –0.101 Mpa [Gauge] (–760 mmHg).

Remove the gauge manifold valve quickly from the service port of the stop valve.

After refrigerant pipes are connected and evacuated, fully open all stop valves on both sides of gas pipe and
liquid pipe.
Operating without fully opening lowers the performance and this causes trouble.

Pipe length up to 7 m

No gas charge is needed.

Pipe length exceeding 7 m

Charge the prescribed

amount of gas. (refer to 3)

Tighten the cap to the service port to obtain the initial status.

Retighten the cap

Leak test

3

Mode

COOL

(Light)

(Off)

Operation indicator

lamp

STOP

(Lights not turn on)

HEAT

(Off)

(Light)

2

1

Close

Open

Hexagonal
wrench

Stop valve

Gage manifold valve

Charge hose

Stop valve

Liquid pipe

Hexagonal wrench

Gas pipe

Service port

Stop valve

Caps

Vacuum pump

2

Mode

COOL

(Light)

(Off)

Operation indicator

lamp

STOP

(Lights not turn on)

1

Содержание MUCF-13NV

Страница 1: ...SORIES 3 4 INDOOR UNIT INSTALLATION 4 5 OUTDOOR UNIT INSTALLATION 9 6 INDOOR OUTDOOR UNIT CONNECTION FINISHING AND TEST RUN 10 7 FOR MOVEMENT AND MAINTENANCE 12 Floor and CeilingType Air Conditioner MCF 13NV 18NV 24NV Series MCFH 13NV 18NV Series FLARE CONNECTION TYPE English Deutsch Français Nederlands Español Italiano ÏÏËÓÈÎ Português Dansk Svenska Türkçe Русский ...

Страница 2: ...p from the unit and household goods could be wet and damaged Please provide an exclusive circuit for the air conditioner and do not connect other electrical appliances to it Please report to your supply authority or obtain their consent before connecting this equipment to the power supply system Be sure to read THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY before installing the air conditione...

Страница 3: ...unit MUCFH type A Drain socket 1 B Drain cap ø33 2 C Drain cap ø16 only MUCFH 18NV 1 PARTS TO BE PROVIDED AT YOUR SIDE Item Q ty A Refrigerant pipe 1 set B Indoor outdoor connecting wire 1 C Piping tape 1 D Drain pipe PVC pipe OD ø26 1 E Pipe fixing band for refrigerant pipe The quantity depends on the pipe length 2 to 5 F Fixing screw for E The quantity depends on the pipe length 2 to 5 G Drain j...

Страница 4: ...llation plate fixing bolts Use installation pattern to determine the locations of instal lation plate fixing bolts J a Installation pattern Details are printed on pattern Attention Surrounding temperature and humidity conditions may cause paper pattern to shrink or expand Measure dimensions before drilling holes 2 Suspension structure Give site of suspension strong struc ture Wood structure Select...

Страница 5: ...wn in Fig 2 Be sure to confirm letters FRONT in installation plates 1 set FRONT side to air outlet side of indoor unit a FRONT 1 Installation plate 2 In case of fixing installation plates 1 above the ceiling put installation plates fixing bolt through a nut a spring washer the installation plate a spring washer and double nut Fig 3 In case of fixing installation plates 1 forward the ceiling direct...

Страница 6: ...irm the dimensions as below 4 2 4 FRONT GRILLE REMOVAL See to 4 1 4 Page 5 4 2 5 OPENING KNOCKOUT HOLE See to 4 1 5 Page 5 Installation pattern Remove installation pattern after installing Horizontal base line Hole for refrigerant and drain pipe in the case of downward piping Hole for refrigerant and drain pipe in the case of rear piping Installation plate 1 FRONT 4 2 6 FIXING UNIT TO INSTALLATION...

Страница 7: ...ward 2 Be sure to fix the cable by cable clamp 3 Replace the terminal cover securely Warning Attach the electrical part cover securely If it is attached incorrectly it could result in a fire an elec tric shock due to dust water etc Use the specified indoor outdoor unit connecting wire to connect the indoor and outdoor units and fix the wire to the terminal block securely so that no stress is appli...

Страница 8: ...nward inclination of 1 100 or more d Air bleeder e Do not raise f Odor trap g The end of drain hose is immersed in water h Gap from the ground level is 50 mm or less i Sewage ditch b c a 0 75 m 1 5 m i g h f e d Be sure to connect drain pipe D to drain joint bush se curely as shown in the right Be sure to pass drain pipe D with drain pipe cover through knockout hole on bottom surface so as to keep...

Страница 9: ...g 45 mm 15 mm Loosen terminal screw Terminal block Lead wire Connection details Caution Be careful not to make mis wiring Firmly tighten the terminal screws to prevent them from loosening After tightening pull the wires lightly to confirm that they do not move If the connecting wire is incorrectly connected to the terminal block the unit does not operate nor mally Warning Be sure to attach the ser...

Страница 10: ...b a 6 INDOOR OUTDOOR UNIT CONNECTION FINISHING AND TEST RUN 6 2 PIPE CONNECTION 1 Indoor unit connection Connect both liquid and gas piping to the indoor unit Apply a thin coat of refrigerant oil on the seat surface of pipe For connection first align the center then hand tighten the first 3 to 4 turns of flare nut Use tightening torque table below as a guideline for the indoor unit side union join...

Страница 11: ...sed by commands from the remote control Once the compressor stops the restart preventive device operates so the compressor will not operate for 3 minutes to protect the air conditioner EMERGENCY OPERATION switch 6 3 PURGING PROCEDURES LEAK TEST PURGING PROCEDURES Connect the refrigerant pipes both the liquid pipe and the gas pipe between the indoor and the outdoor unit Remove the service port cap ...

Страница 12: ...on mode set temperature and the fan speed are memorized by the indoor electronic control P C board The auto restart function sets to work the moment the power has restored after power failure then the unit will restart automatically If the unit is operated in I FEEL CONTROL mode before power failure the operation is not memorized In I FEEL CONTROL mode the operation is decided by the initial room ...

Страница 13: ... J24532 CABLE MELCO TOKYO This product is designed and intended for use in the residential commercial and light industrial environment The product at hand is based on the following EU regulations Low Voltage Directive 73 23 EEC Electromagnetic Compatibility Directive 89 336 EEC ...

Отзывы: