40
J Check of power supply
Is there voltage 208/230 V AC
between the indoor terminal
block S1 and S2?
Yes
No
Replace the indoor
electronic control P.C.
board.
Rectify indoor/outdoor
connecting wire.
Yes
If lights up, OK.
If blinks, refer to 10-3.
Does the upper lamp of the
OPERATION INDICATOR lamp on
the indoor unit light up?
Does LED on the inverter P.C.
board light up or blink?
(Refer to 10-6.1.)
No
Replace the inverter
P.C. board.
Is there DC voltage 260 - 370 V DC
between DB61 (+) and DB61 (–) on
the inverter P.C. board?
(Refer to 10-6.1.)
No
Check the electric parts in main circuit.
Yes
Yes
No
Disconnect the connector between the
compressor and the power module (IC700)
Turn ON power supply and press
EMERGENCY OPERATION switch.
Inverter P.C. board
(Solder side)
DB61
260 - 370 V DC
OBH819A
Содержание MSZ-WR NA Series
Страница 9: ...9 5 WIRING DIAGRAM MUZ WR09NA MUZ WR12NA MUZ WR18NA OBH819A ...
Страница 10: ...10 MUZ WR24NA OBH819A ...
Страница 57: ...57 OBH819A ...