9-17. EMERGENCY/TEST OPERATION
In the case of test run operation or emergency operation, use the emer-
gency operation switch on the right side of the indoor unit. Emergency
operation is available when the remote controller is missing or has failed,
or when the batteries in the remote controller are running down. The unit
will start and OPERATION INDICATOR lamp will light up.
The first 30 minutes of operation is the test run operation. This opera-
tion is for servicing. The indoor fan runs at High speed and the tem-
perature control does not work.
After 30 minutes of test run operation, the system shifts to
EMERGENCY COOL/HEAT MODE with a set temperature of 24°C.
The fan speed shifts to Med.
The coil frost prevention works even in the test run or the emergency
operation.
In the test run or emergency operation, the horizontal vane operates in
VANE AUTO ( ) mode.
Emergency operation continues until the emergency operation switch is
pressed once or twice or the unit receives any signal from the remote
controller. In the latter case, normal operation will start.
NOTE:
Do not press the emergency operation switch during normal
operation.
9-18. 3-MINUTE TIME DELAY OPERATION
When the system turns OFF, compressor will not restart for 3 minutes as 3-minute time delay function operates to protect
compressor from overload.
Emergency
operation switch
(E.O. SW)
Operation indicator lamp
Emergency COOL
Emergency HEAT
Stop
Operation mode COOL/HEAT
Set temperature
24°C
Fan speed
Med.
Horizontal vane
Auto
The operation mode is indicated by the Operation
Indicator lamp as following
OBH902A