2-4. PIPE FORMING AND DRAIN PIPING

Pipe Forming

‡

  Place the drain hose 

E

elow the refrigerant piping

‡

  Make sure that the drain hose is not heaved or snaked

‡

 

'

o not pull the hose when applying the tape

‡

  When the drain hose passes the room, 

E

e sure to wrap insula

tion material (o

E

taina

E

le at a store) around it

2-1. FIXING OF INSTALLATION PLATE

‡

  Find a structural material (such as a stud) in the wall and 

¿

x installation plate (1) horizon

tally 

E

y tightening the 

¿

xing screws (2) 

¿

rmly

‡

  To prevent installation plate (1) from vi

E

rating, 

E

e sure to install the 

¿

xing screws in the 

holes indicated in the illustration

 For added support, 

¿

xing screws may also 

E

e installed 

in other holes

‡

  When the knockout is removed, apply vinyl tape to the knockout edges to prevent damag

ing the wires

‡

 When 

E

olts recessed in the concrete wall are to 

E

e utilized, secure installation plate (1) 

using 11 × 20 

ā

 11 × 26 oval hole (450 mm pitch)

‡

  If the recessed 

E

olt is too long, change it for a shorter one availa

E

le in the market

2-2. WALL HOLE DRILLING

1) 

'

etermine the wall hole position

2) 

'

rill a ø65 mm hole

 The outdoor side should 

E

e 5 to 

7  mm lower than the indoor side

3) Insert wall hole sleeve (C)

2-3. CONNECTING WIRES FOR INDOOR UNIT

<

ou can connect indoor/outdoor lead wire without removing the front panel

1) Open the front panel

2) Remove VA clamp

3)  Pass indoor/outdoor unit connecting wire (A)  from the 

E

ack of the indoor unit and process 

the end of the wire

4) Loosen terminal screw, and connect 

¿

rst the earth wire, then indoor/outdoor unit con

necting wire (A) to the terminal 

E

lock

 

%

e careful not to make mis

wiring

 Fix the wire to 

the terminal 

E

lock securely so that no part of its core is appeared, and no external force 

is conveyed to the connecting section of the terminal 

E

lock

 

5) Firmly tighten the terminal screws to prevent them from loosening

 After tightening, pull 

the wires lightly to con

¿

rm that they do not move

6) Secure indoor/outdoor unit connecting wire (A) and the earth wire with the VA clamp

 

Never fail to hook the left claw of the VA clamp

 Attach the VA clamp securely

2.  INDOOR UNIT INSTALLATION

Rear, right, or downward piping

1) Put the refrigerant piping and the drain hose together, then 

¿

rmly apply piping tape (G) from the end

2) Insert the piping and the drain hose into the wall hole sleeve 

(C), and hook the upper part of the indoor unit on the instal

lation plate (1)

3) Check if the indoor unit is hooked securely on the installation plate (1) 

E

y moving the 

unit to left and right

4) Thrust the lower part of the indoor unit into the installation plate (1)

Drain Piping

‡

  If the extension drain hose has to pass through a room, 

E

e sure to wrap it with commer

cially sold insulation

 

‡

  The drain hose should point downward for easy drain 

À

ow

 (Fig

 1)

‡

  If the drain hose provided with the indoor unit is too short, connect it with drain hose (I) 

that should 

E

e provided at your site

 (Fig

 2)

‡

  When connecting the drain hose to the hard vinyl chloride pipe, 

E

e sure to insert it securely 

into the pipe

 (Fig

 3)

'

o not make drain piping as shown 

E

elow

'

o not raise

Accumulated 
drain water

Air

Waving

Water 
leakage

Water 
leakage

Water 
leakage

Tip of drain 
hose dipped 
in water

'

itch

At least 
50 mm 
gap

'

ownward 

slope

'

rain 

hose

Soft hose 
I

'

 15 mm

'

rain hose

+

ard vinyl chloride 

pipe I

'

 30 mm

Insert 
securely

'

ifferent 

diameter joint

70 cm 
or more

Fig

 

1

Fig

 

2

Fig

 3

‡

  For future servicing, give extra length to 

the connecting wires

‡

  Make earth wire a little longer than others

 

(More than 60 mm)

‡

 

'

o not fold the excess wire, or cram it into 

small space

 Take caution not to damage 

the wires

‡

 

%

e sure to attach each screw to its corre

spondent terminal when securing the cord 
and/or the wire to the terminal 

E

lock

Note:

 

'

o not place the wires 

E

etween the 

indoor unit and the installation plate (1)

 

'

amaged wire could cause heat genera

tion or 

¿

re

 

Wall

Outdoor 
side

ø65 mm

5

7 mm

Installation plate (1)

Center of 
ø65 mm hole

111

 mm 

or more

101

 mm 

or more 

60

 mm or more

150

 mm or more for left and left 

E

ack piping (using spacer)

Ceiling

Wall

Wall

Fixing 
screw (2)

100 mm

Level 

* Same for left hole

Lead wire

15 mm

35 mm

Fixing screw

VA clamp

Indoor/outdoor unit 
connecting wire (A)

Indoor terminal 

E

lock

Indoor/outdoor 
unit connecting 
wire (A)

Outdoor terminal 

E

lock

Earth wire 
(green/yellow)

S1 S2 S3

S1 S2 S3

Felt tape (4)

Piping tape (G)

Cut off in case of 
left piping

'

rain cap

'

rain cap

'

rain hose

'

rain cap

'

rain hose

Fig

 1

Fig

 2

Fig

 3

Fig

 4

Fig

 5

1) Put the refrigerant piping and the drain hose together, 

then 

¿

rmly apply felt tape (4) from the end

 

 

Felt tape (4) overlap width should 

E

e 1/3 the tape width

 

Use a 

E

andage stopper at the end of felt tape (4)

2) Pull out the drain cap at the rear right of the indoor unit

 

(Fig

 1)

‡

 

+

old the convex section at the end and pull the drain 

cap

3) Pull out the drain hose at the rear left of the indoor unit

 

(Fig

 2)

‡

 

+

old the claw marked 

E

y the arrows and pull out the 

drain hose forward

4)  Put the drain cap into the section to which the drain hose 

is to 

E

e attached at the rear of the indoor unit

 (Fig

 3)

‡

  Insert not sharp

edged tools such as screwdrivers into 

the hole at the end of the cap and insert the cap fully 
into the drain pan

5) Insert the drain hose fully into the drain pan at the rear 

right of the indoor unit

 (Fig

 4)

‡

  Check if the hose is hooked securely to the projection 

of its inserting part at the drain pan

6) Insert the drain hose into wall hole sleeve (C), and hook 

the upper part of indoor unit on installation plate (1)

 

Then, move the indoor unit completely to the left in order 
to make placing the piping in the 

E

ack space of the unit 

easier

7) Cut out a piece of card

E

oard from the shipping 

E

ox, roll 

it up, hook it onto the 

E

ack ri

E

, and use it as a spacer to 

lift the indoor unit

 (Fig

 5)

8) Connect the refrigerant piping with the extension pipe 

(

%

)

9)  Thrust the lower part of the indoor unit into the installation 

plate (1)

Left or left-rear piping
Note:

%

e sure to reattach the drain hose 

and the drain cap in case of left or 
left

rear piping

Otherwise, it could cause drops of 
water to drip down from the drain 
hose

Liquid pipe

Gas pipe

Felt tape (4) 

Indoor/outdoor unit 
connecting wire (A)

Piping tape (G)

Insert the 
scale

 *

Align the 
scale with 
the line

 *

Содержание MSZ-LN25VG

Страница 1: ...ply plug replace it Attach the electrical cover to the indoor unit and the service panel to the outdoor unit securely If the electrical cover of the indoor unit and or the service panel of the outdoor unit are not attached securely it could result in a re or an electric shock due to dust water etc When installing relocating or servicing the unit make sure that no substance other than the speci ed ...

Страница 2: ...nd If the outdoor unit is exposed to a wind during defrosting the defrosting time will Ee longer Where airÀow is good and dustless Where rain or direct sunlight can Ee avoided as much as possiEle Where neighEours are not annoyed Ey operation sound or hot or cool air Where rigid wall or support is availaEle to prevent the increase of operation sound or viEration Where there is no risk of comEustiEl...

Страница 3: ...r purifying device 1 Outdoor unit 12 rain socket VG type only 1 Air inlet LN25 35 50 50 Z 60 LN25 35 50 50 Z 60 3 When any 2 sides of left right and rear of unit are clear 4 The manufacturing year and month is indicated on the spec name plate 60 mm or more 150 mm or more for left and left Eack piping using spacer 101 mm or more 111 mm or more 350 mm or more Note Install the unit horizontally o not...

Страница 4: ... pipe Fig 3 o not make drain piping as shown Eelow o not raise Accumulated drain water Air Waving Water leakage Water leakage Water leakage Tip of drain hose dipped in water itch At least 50 mm gap ownward slope rain hose Soft hose I 15 mm rain hose ard vinyl chloride pipe I 30 mm Insert securely ifferent diameter joint 70 cm or more Fig 1 Fig 2 Fig 3 For future servicing give extra length to the ...

Страница 5: ...e 1 part aEout 90 degrees around the hinge point you have just created to put the parts together 3 Press the Ease of portion with the mark to snap into place When changing the part disassemEle Ey moving the part in a reverse direction The parts that were not used may Ee necessary in the future if the air conditioner is relocated so ask customers to keep those parts 4 Attach the assemEled corner Eo...

Страница 6: ...he unit securely connect the refrigerant pipes before starting the compressor 3 1 CONNECTING WIRES FOR OUTDOOR UNIT 1 Open the service panel 2 Loosen terminal screw and connect indoor outdoor unit connecting wire A from the indoor unit correctly on the terminal Elock e careful not to make mis wiring Fix the wire to the terminal Elock securely so that no part of its core is appeared and no external...

Страница 7: ...he unit with the E O SW or the remote controller Eefore turning off the power supply Not doing so will cause the unit to start operation automatically when power supply is resumed To the user After installing the unit make sure to explain the user aEout auto restart function If auto restart function is unnecessary it can Ee deactivated Consult the service representative to deactivate the function ...

Страница 8: ... the pressure gauge shows 0 05 to 0 MPa Gauge approx 0 5 to 0 kgf cmð 6 Stop the emergency COOL operation Press the E O SW several times until all LE lamps turn off Refer to operating instruc tions for details 6 RELOCATION AND MAINTENANCE When pumping down the refrigerant stop the compressor before disconnecting the refrigerant pipes The compressor may burst if air etc get into it WARNING 6 2 REMO...

Отзывы: