background image

En-8

Heat exchanger

•  Wear gloves to protect your hands.

•  Use the QUICK CLEAN KIT 

(option).

 

Parts Number 

 MAC-093SS-E 

•  Refer to the instructions described in 

the  QUICK CLEAN KIT for details.

Front panel

Instructions:

 

1. Lift the front panel until a “click” is heard.
2. Hold the hinges and pull to remove as shown in the above 

illustration.

•  Wipe with a soft dry cloth or rinse it with water.

•  Do not soak it in water for more than two hours.

•  Dry it well in shade.

3. Install  the  panel  by  following  the  removal 

procedure  in  reverse.  Close  the  front  panel 
securely and press the positions indicated by 

the arrows.

Hole

Hinge

Hold the tab

Plasma anti-allergy enzyme fi lter

Every 3 months:

•  Remove dirt by a vacuum cleaner.

When dirt cannot be removed by vacuum cleaning:

• 

Soak the fi lter together with its frame in lukewarm water and rinse it.

• 

After washing, dry it well in shade.

Every year:

•  Replace it with a new air cleaning fi lter for best performance.

•  Parts Number 

 MAC-417FT-E 

Plasma deodorizing fi lter

Every 3 months:

•  Remove dirt by a vacuum cleaner, or soak the fi lter in lukewarm water  

(30 to 40°C) for about 15 minutes. Rinse well.

•  After washing, dry it well in shade. 

•  Deodorizing feature recovers by cleaning the fi lter.

When dirt or smell cannot be removed by cleaning:

•  Replace it with a new air cleaning fi lter.

•  Parts Number 

 MAC-307FT-E 

Air outlet and Fan (before cleaning, make sure that the fan is stopped)

Air fi lter

• 

Clean every 2 weeks

•  Remove dirt by a vacuum cleaner, 

or rinse with water.

•  Dry it well in shade.

C

LEANING

1

Turn the horizontal vanes downward. 

Then, remove the upper vane as 

shown in 

➀ 

and 

.

•  Repeat 

➀ 

and 

➁ 

for the lower vane.

2

Swing out the two vertical vanes 

one by one.

4

Put the vertical vanes back to 

their original positions correctly 
one by one, into their respective 
guide.

•  Push the vanes until they click into place.

3

Clean the air outlet and fan.

•  Wipe with a soft dry cloth.

Clean the fan.

•  Use the QUICK CLEAN KIT (option).

  Parts Number 

 MAC-093SS-E 

•  Refer  to  the  instructions  described  in  the  

QUICK CLEAN KIT for details.

5

Install the horizontal vane by 

following the removal procedure 

in reverse.

•  If the horizontal vane is not installed cor-

rectly, all LED lamps blink when power is 

turned on.

Unlock

•  Switch off the power supply or turn off the breaker before cleaning.

•  Be careful not to touch the metal parts with your hands.

•  Do not use benzine, thinner, polishing powder, or insecticide.

•  Use only diluted mild detergents.

•  Do not expose parts to direct sunlight, heat, or fi re to dry.

•  Do not use water hotter than 50°C.

Guide

Note:

Do  not  apply  excessive  force  to  the  fan  or  fan 

guard.

Note:

•  Clean the fi lters regularly for best performance and to reduce power 

consumption.

•  Do not touch the i-see sensor.

i-see sensor

Do  not  touch  the  i-see 
sensor.

090616 SG79F259H04.indd   8

2009/07/02   13:01:39

Содержание MSZ-FB25VA

Страница 1: ...IT TYPE AIR CONDITIONERS INDOOR UNIT MSZ FB25VA MSZ FB35VA MSZ FB50VA English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use ...

Страница 2: ... conditions Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside rotates at high speeds during operation In case of an abnormal condition such as a burning smell stop the air conditioner and disconnect the power plug or turn the breaker OFF A continued operation in the abnormal state may cause a malfunction fire or electric shock ...

Страница 3: ...e breaker OFF when you hear thunder and there is a possibility of a lightning strike The unit may be damaged if lightning strikes After the air conditioner is used for several seasons per form inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor or clog the drain passage and cause water to leak from the indoor unit Consult your dealer for...

Страница 4: ...age 7 FAN speed control button Page 6 Off timer button Page 7 On timer button Page 7 VANE control button Page 6 TIME set buttons Pages 3 7 Increase time Decrease time CLOCK button Page 3 RESET button Page 3 Lid Slide down to open Install the remote control ler holder in a place where the signal can be received by the indoor unit Only use the remote controller provided with the unit Do not use othe...

Страница 5: ...c is more than 50 cm to the left and right Right Distance to objects wall cabinet etc is less than 50 cm to the right Area Left Center Right Slide switch Remote controller display Press to activate i see control operation Press gently using a thin instrument lights Operation display section The default setting is active Press again to release i see control operation Slide switch i see control oper...

Страница 6: ...igh Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power When timer is set timer setting is cancelled and the unit starts operation when power is resumed If you do not want to use this function please c...

Страница 7: ...indoor unit when set to AUTO Press to select horizontal airflow direction Each press changes airflow direction in the following order AUTO Low Med High Super High AUTO 1 2 3 4 5 SWING SWING Vertical airflow direction AUTO The vane is set to the most efficient airflow direction COOL DRY horizontal position HEAT downward position Manual For efficient air conditioning select upper position for COOL DRY a...

Страница 8: ...p turns on Display section Press again to cancel PLASMA operation What is PLASMA operation Plasma operation consists of deodorizing and air purifying features Particles of odor releasing substances are absorbed and decomposed by the plasma deodorizing filter Particles of allergens such as pollens and house dust are collected by the plasma anti allergy filter These filters work with negative ions gene...

Страница 9: ... a new air cleaning filter Parts Number MAC 307FT E Air outlet and Fan before cleaning make sure that the fan is stopped Air filter Clean every 2 weeks Remove dirt by a vacuum cleaner or rinse with water Dry it well in shade CLEANING 1 Turn the horizontal vanes downward Then remove the upper vane as shown in and Repeat and for the lower vane 2 Swing out the two vertical vanes one by one 4 Put the ve...

Страница 10: ...ng capacity Water leaks from the outdoor unit During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation water condensed on the heat exchanger drips down In the heating operation the defrosting op eration makes water frozen on the outdoor unit melt and drip down Symptom Explanation Check points Outdoor Unit White smoke is d...

Страница 11: ...event the effects of a fluorescent lamp keep as far apart as possible wall etc Inverter type fluorescent lamp Keep a space to prevent the pic ture distortion or the noise 1 m or more Radio 100 mm or more Well ventilated dry place 200 500 mm or more TV Cordless phone or Portable phone 3 m or more 1 m or more The installation location of the outdoor unit should be at least 3 m away from the antennas f...

Страница 12: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79F259H04 ...

Отзывы: