27
12V
GND
5V
Room temperature thermistor (RT11)
Indoor coil thermistor (RT12, RT13)
Temperature (°C)
Resistance (k
Ω
)
Fuse (F11)
T3.15AL250V
Varistor (NR11)
Connector to indoor electronic
control P.C. board (CN20A)
5 VDC
12 VDC GND
Connector to
Indoor fan motor
(CN211)
Resistor (R111)
Connector to
Terminal block
(CN201)
Indoor terminal block
connecting (TAB1)
(+)3-6 VDC
15 VDC
(-) GND
(High voltage DC)
325 VDC
(+)0 or 15 VDC
Indoor terminal block
connecting (TAB2)
Timer short
mode point
(Refer to
8-1.)
Room temperature thermistor RT11 (CN111)
Connector to
Indoor coil
thermistor
RT12, RT13
(CN112)
Vane motor
(CN151)
Connector to indoor power
P.C. board (CN10A)
12V DC
5V DC
To disable "Auto restart function",
cut the Jumper wire to JR77.
(Refer to 8-3.)
Emergency operation
switch (E.O. SW) (SW1)
GND
MSZ-DM25VA MSZ-DM35VA
1. Indoor power P.C. board
10-7. TEST POINT DIAGRAM AND VOLTAGE
2. Indoor electronic control P.C. board
OBH750