Even if these items are checked, when the unit does not recover from the 
trouble, stop using the air conditioner and consult your dealer.

Symptom

Explanation & Check points

Indoor Unit

The unit cannot be operated.

•  Is the breaker turned on?
•  Is the power supply plug connected?
•  Is the ON timer set? 

 Page 6 

All LED lamps on the indoor 
unit are blinking.

•  Are the horizontal vanes installed correctly? 

 Page 7 

The horizontal vane does not 
move.

•  Are the horizontal vane and the vertical vane 

installed correctly? 

 Page 7 

•  Is the fan guard deformed?

The unit cannot be operated 
for about 3 minutes when 
restarted.

•  This protects the unit according to instruc-

tions from the microprocessor. Please 
wait.

Mist is discharged from the air 
outlet of the indoor unit.

•  The cool air from the unit rapidly cools mois-

ture in the air inside the room, and it turns 
into mist.

The swing operation of the 
HORIZONTAL VANE is 
suspended for a while, then 
restarted.

•  This is for the swing operation of the HORI-

ZONTAL VANE to be performed normally.

The air fl ow direction changes 
during operation.
The direction of the horizontal 
vane cannot be adjusted with 
the remote controller.

•  When the unit is operated in COOL or DRY 

mode, if the operation continues with air 
blowing down for 0.5 to 1 hour, the direction 
of the air fl ow is automatically set to horizon-
tal position to prevent water from condensing 
and dripping.

•  In the heating operation, if the air fl ow tem-

perature is too low or when defrosting is be-
ing done, the horizontal vane is automatically 
set to horizontal position.

The operation is stopped for 
about 10 minutes in the heat-
ing operation.

•  Defrosting of the outdoor unit is being done.
  Since this is completed in max.10 minutes, 

please wait. (When the outside temperature 
is too low and humidity is too high, frost is 
formed.)

The unit starts operation by 
itself when the main power 
is turned on, though it isn’t 
operated with the remote 
controller.

•  These models are equipped with an auto re-

start function. When the main power is turned 
off without stopping the unit with the remote 
controller and is turned on again, the unit 
starts operation automatically in the same 
mode as the one set with the remote control-
ler just before the shutoff of the main power. 
Refer to “Auto restart function” 

 page 4 

.

The indoor unit discolors over 
time.

•  Although plastic turns yellow due to the infl u-

ence of some factors such as ultraviolet light 
and temperature, this has no effect on the 
product functions.

Multi system

The indoor unit which is not 
operating becomes warm and 
a sound, similar to water fl ow-
ing, is heard from the unit.

•  A small amount of refrigerant continues to 

fl ow into the indoor unit even though it is not 
operating.

When heating operation is 
selected, operation does not 
start right away.

•  When operation is started during defrosting 

of outdoor unit is done, it takes a few minutes 
(max. 10 minutes) to blow out warm air.

Outdoor Unit

The fan of the outdoor unit 
does not rotate even though 
the compressor is running. 
Even if the fan starts to rotate, 
it stops soon.

• When the outside temperature is low dur-

ing cooling operation, the fan operates 
intermittently to maintain suffi cient cooling 
capacity.

Water leaks from the outdoor 
unit.

•  During COOL and DRY operations, pipe or 

pipe connecting sections are cooled and this 
causes water to condense.

•  In the heating operation, water condensed 

on the heat exchanger drips down.

•  In the heating operation, the defrosting op-

eration makes water frozen on the outdoor 
unit melt and drip down.

White smoke is discharged 
from the outdoor unit.

• In the heating operation, vapor generated 

by the defrosting operation looks like white 
smoke.

Symptom

Explanation & Check points

Remote controller

The display on the remote 
controller does not appear 
or it is dim. The indoor unit 
does not respond to the 
remote control signal.

•  Are the batteries exhausted? 

 Page 3 

•  Is the polarity (+, -) of the batteries correct?

 Page 3 

•  Are any buttons on the remote controller of 

other electric appliances being pressed?

Does not cool or heat

The room cannot be cooled 
or heated suffi ciently.

• Is the temperature setting appropriate? 

 Page 4 

•  Is the fan setting appropriate? Please change 

fan speed to higher setting. 

   

 Page 5 

•  Are the fi lters clean? 

 Page 7 

•  Is the fan or heat exchanger of the indoor unit 

clean? 

 Page 7 

•  Are there any obstacles blocking the air inlet 

or outlet of the indoor or outdoor unit?

•  Is a window or door open?

The room cannot be cooled 
suffi ciently.

• When a ventilation fan or a gas cooker is 

used in a room, the cooling load increases, 
resulting in an insuffi cient cooling effect.

• When the outside temperature is high, the 

cooling effect may not be suffi cient.

The room cannot be heated 
suffi ciently.

• When the outside temperature is low, the 

heating effect may not be suffi cient.

Air does not blow out soon in 
the heating operation.

•  Please wait as the unit is preparing to blow 

out warm air.

Airfl ow

The air from the indoor unit 
smells strange.

•  Are the fi lters clean? 

 Page 7 

•  Is the fan or heat exchanger of the indoor unit 

clean? 

 Page 7 

•  The unit may suck in an odor adhering to the 

wall, carpet, furniture, cloth, etc. and blow it 
out with the air.

Sound

Cracking sound is heard.

• This sound is generated by the expansion/

contraction of the front panel, etc. due to 
change in temperature.

“Burbling” sound is heard.

•  This sound is heard when the outside air is 

absorbed from the drain hose by turning on 
the range hood or the ventilation fan, making 
water fl owing in the drain hose to spout out.

  This sound is also heard when the outside air 

blows into the drain hose in case the outside 
wind is strong.

Mechanical sound is heard 
from the indoor unit.

•  This is the switching sound in turning on/off 

the fan or the compressor.

The sound of water fl owing 
is heard.

•  This is the sound of refrigerant or condensed 

water fl owing in the unit.

Hissing sound is sometimes 
heard.

•  This is the sound when the fl ow of refrigerant 

inside the unit is switched.

In the following cases, stop using the air conditioner and consult your dealer.

•  When water leaks or drips from the indoor unit.
•  When the upper operation indicator lamp blinks.
•  When the breaker trips frequently.
•  The remote control signal is not received in a room where an electronic ON/OFF 

type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.

•  Operation of the air conditioner interferes with radio or TV reception. An ampli-

fi er may be required for the affected device.

•  When an abnormal sound is heard.

W

HEN YOU THINK THAT TROUBLE HAS OCCURRED

Все каталоги и инструкции здесь:

 http

:

//splitoff.ru/tehn-doc.html

Содержание MSZ-CGE22VA

Страница 1: ...rectamente e com segurança certifique se de que lê estas instruções de operação antes da utilização ΟΔΗΓΙΕΣ ΛΕΙΤΟΥΡΓΙΑΣ Για το χρήστη Για να χρησιμοποιήσετε αυτή τη μονάδα σωστά και με ασφάλεια βεβαι ωθείτε ότι έχετε διαβάσει αυτό το εγχειρίδιο οδηγιών πριν από τη χρή ση LIBRETTO D ISTRUZIONI Per gli utenti Per utilizzare correttamente ed in tutta sicurezza questo apparecchio leggere il presente li...

Страница 2: ... electric shock injury or water leakage etc Consult your dealer If the power supply cord is damaged it must be replaced by the manufacturer or its service agent in order to avoid a hazard When installing relocating or servicing the unit make sure that no substance other than the specified refrigerant R410A enters the refrigerant circuit Any presence of foreign substance such as air can cause abnorm...

Страница 3: ... at high speeds during operation When the unit will be unused for a long time disconnect the power plug or turn the breaker OFF The unit may accumulate dirt which may cause overheating or fire Replace all batteries of the remote controller with new ones of the same type Using an old battery together with a new one may cause overheat ing leakage or explosion If the battery fluid comes in contact with...

Страница 4: ...uttons to set the time Each press increases decreases the time by 1 minute 10 minutes when pressed longer Indoor unit Remote controller Outdoor units may be different in appearance 1 Remove the front lid 2 Insert AAA alkaline batteries 3 Install the front lid 4 Press RESET Air cleaning filter Anti Allergy Enzyme Filter option Remote controller holder Signal transmitting section Distance of signal A...

Страница 5: ...ff during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power When timer is set timer setting is cancelled and the unit starts operation when power is resumed If you do not want to use this function please consult the service repre sentative because the setting of the unit needs to be ch...

Страница 6: ...ne manually before starting operation 1 Press during COOL ECONO COOL or HEAT mode to select i save mode 2 Set the temperature fan speed and air flow direction The same setting is selected from the next time by simply pressing Two groups of setting can be saved One for COOL ECONO COOL one for HEAT Select the appropriate temperature fan speed and airflow direction according to your room Normally the ...

Страница 7: ... to perform cooling operation with keeping comfort As a result energy can be saved 1 Press or during operation to set the timer ON timer The unit turns ON at the set time OFF timer The unit turns OFF at the set time or blinks Make sure that the current time is set correctly Page 3 2 Press Increase and Decrease to set the time of timer Each press increases or decreases the set time by 10 minutes Se...

Страница 8: ...old the hinges and pull to remove as shown in the above illustration Wipe with a soft dry cloth or rinse it with water Do not soak it in water for more than two hours Dry it well in shade 3 Install the panel by following the removal proce dure in reverse Close the front panel securely and press the positions indicated by the arrows Hole Hinge Air cleaning filter Anti Allergy Enzyme Filter option Ba...

Страница 9: ...cooling capacity Water leaks from the outdoor unit During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation water condensed on the heat exchanger drips down In the heating operation the defrosting op eration makes water frozen on the outdoor unit melt and drip down White smoke is discharged from the outdoor unit In the he...

Страница 10: ...ower sup ply plug 4 Remove all batteries from the remote controller When using the air conditioner again 1 Clean the air filter Page 7 2 Check that the air inlet and outlet of the indoor and outdoor units are not blocked 3 Check that the earth is connected correctly WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME Indoor Outdoor MUZ GE25 35 42 50VA MUZ GE25 35 42 50VAH Cooling Upper...

Страница 11: ...й разборка или ремонт блока не должны осуществляться пользователем Неправильное обращение с кондиционером может привести к возникновению пожара поражению электротоком травмам и подтеканию воды Проконсультируйтесь с дилером При наличии повреждения в шнуре питания его следует заменить у производителя или его сервисного представителя во избежание опасной ситуации При установке перемещении или техобсл...

Страница 12: ...ой может произойти перегрев утечка или взрыв Если электролит попадет на вашу кожу или одежду тщательно смойте его чистой водой Если электролит попадет в глаза тщательно промойте их чистой водой и сразу же обратитесь к врачу Убедитесь что место хорошо вентилируется при работе блока с легковоспламеняющимися приборами Недостаточная вентиляция может привести к кислородному голо данию Установите выключ...

Страница 13: ... кнопки TIME чтобы установить время При каждом нажатии происхо дит увеличение уменьшение времени на 1 минуту 10 минут при длительном нажатии Внутренний прибор Пульт дистанционного управления Внешний вид устройств предназначенных для использования на улице может отличаться 1 Снимите переднюю крышку 2 Вставьте ще лочные бата рейки типа AAA 3 Установите переднюю крышку 4 Нажмите кнопку RESET Фильтр о...

Страница 14: ...ние прибора было выключено во вре мя его работы функция повторного автозапуска автоматически настраивает прибор на работу в том режиме который был задан с помощью пульта дистанционного управления до отключения электропитания Когда таймер установлен настройка таймера отменяется и блок начинает работу при возобновлении подачи питания Если вы не хотите пользоваться этой функцией обратитесь к представ...

Страница 15: ...еред запуском операции переместите вертикальную заслонку вручную 1 Для выбора режима i save нажмите во время работы кондиционера в режимах COOL ECONO COOL или HEAT 2 Задайте температуру скорость вентилятора и на правление воздушного потока Эта же настройка выбирается в следующий раз путем нажатия Можно сохранять две группы настроек Одну для режима COOL ECONO COOL а вторую для режима HEAT Выберите ...

Страница 16: ...возможность осуществления операции охлаждения и поддерживаются комфортные условия В результате можно экономить электроэнергию 1 Во время операции нажмите или чтобы установить таймер таймер ВКЛЮЧЕНИЯ В заданное время прибор ВКЛЮЧИТСЯ таймер ВЫКЛЮЧЕНИЯ В заданное время при бор ВЫКЛЮЧИТСЯ или мигает Убедитесь что время задано правильно Стр 3 2 Нажмите Увеличить и Уменьшить что бы задать время таймера...

Страница 17: ...ь до тех пор пока она не зафиксируется на месте со щелчком 2 Придерживайте петли и тяните чтобы снять как показано на иллюстрации выше Протирайте мягкой сухой тканью или промывайте водой Не держите ее в воде более двух часов Сушите изделия в тени надлежащим образом 3 Устанавливайте переднюю панель выполняя инс трукции по ее снятию в обратном порядке Надежно закройте переднюю панель и нажмите на об...

Страница 18: ...туре наружного воздуха вентилятор может включаться и выключаться чтобы поддерживать достаточную мощность охлаждения Из наружного прибора выте кает вода При работе в режимах COOL ОХЛАЖ ДЕНИЕ и DRY СУШКА происходит охлаждение труб и трубных соединений что вызывает конденсацию влаги При работе в режиме обогрева конденсат образовавшийся на теплообменнике стекает вниз При работе в режиме обогрева во вр...

Страница 19: ...луатации Охлаждение Внутренний 27 C DB 19 C WB Наружный 35 C DB Обогрев Внутренний 20 C DB Наружный 7 C DB 6 C WB 2 Отдельное использование CGE22 не предусмотрено Данная модель внутреннего прибора предназначена только для мульти системного кондиционера По вопросам технических характеристик мультисистемной моде ли обратитесь к своему дилеру и или см каталог Гарантированный рабочий диапазон DB сухой...

Страница 20: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79F301H04 Все каталоги и инструкции здесь http splitoff ru tehn doc html ...

Отзывы: