background image

En-9

● OPERATING INSTRUCTIONS ●

Installation place

Avoid installing the air conditioner in the following places.

•  Where there is much machine oil.
•  Salty places such as the seaside.
•  Where sulfi de gas is generated such as a hot spring.
•  Where oil is splashed or where the area is fi lled with oily smoke.
•  Where there is high-frequency or wireless equipment.
•  Where the air from the outdoor unit air outlet is blocked.
•  Where the operation sound or air from the outdoor unit does not bother the 

house next door.

Electrical work

•  Provide an exclusive circuit for the power supply of the air conditioner.
•  Be sure to observe the breaker capacity.

If you have any questions, consult your dealer.

I

NSTALLATION PLACE AND 

ELECTRICAL WORK

S

PECIFICATIONS

To prevent the effects 
of a fl uorescent lamp, 
keep as far apart as 
possible.

wall, etc.

Inverter-type 
fl uorescent lamp

Keep a space to 
prevent the pic-
ture distortion or 
the noise.

1 m 
or more

Radio

100 mm or 
more

Well- 
ventilated dry 
place

(GE25, 35, 
42/GE50)
200/500 mm 
or more

TV

Cordless 
phone or 
Portable 
phone

3 m or 
more

1 m 
or more

The installation location of the outdoor unit should 
be at least 3 m away from the antennas for TV sets, 
radios, etc. In areas where the reception is weak, 
provide greater space between the outdoor unit and 
the antenna of the affected device if operation of the air 
conditioner interferes with radio or TV reception.

1

Set to the highest temperature in manual COOL mode, 
and operate for 3 to 4 hours. 

 Page 4 

•  This dries the inside of the unit.
•  Moisture in the air conditioner contributes to growth of fungi, such as 

mold.

2

Press 

 to stop the operation.

3

Turn off the breaker and/or disconnect the power sup-
ply plug.

4

Remove all batteries from the remote controller.

When using the air conditioner again:

1

Clean the air fi lter. 

 Page 7 

2

Check that the air inlet and outlet of the indoor and 
outdoor units are not blocked.

3

Check that the earth is connected correctly.

W

HEN THE AIR CONDITIONER IS NOT 

GOING TO BE USED FOR A LONG TIME

Indoor

Outdoor

MUZ-GE25/35/42/50VA MUZ-GE25/35/42/50VAH

Cooling

Upper limit

32°C DB

23°C WB

46°C DB

46°C DB

Lower limit

21°C DB

15°C WB

-10°C DB

-10°C DB

Heating

Upper limit

27°C DB

24°C DB

18°C WB

24°C DB

18°C WB

Lower limit

20°C DB

-15°C DB

-16°C WB

-20°C DB

-21°C WB

Note:

1. Rating condition
 

Cooling — Indoor: 

27°C DB, 19°C WB

  

Outdoor: 35°C 

DB

 

Heating — Indoor: 

20°C DB

 

 

Outdoor:  7°C DB, 6°C WB

2.  CGE22 has no specifi cations for single combination. This indoor model 

is only for multi system air conditioner. 

  As for the specifi cations of multi system, please confi rm your dealer 

and/or refer to the catalogue.

Guaranteed operating range

DB: Dry Bulb
WB: Wet Bulb

Model

Set name

MSZ-CGE25VA(H)

MSZ-CGE35VA(H)

MSZ-CGE42VA(H)

MSZ-CGE50VA(H)

Indoor

MSZ-CGE22VA

MSZ-CGE25VA

MSZ-CGE35VA

MSZ-CGE42VA

MSZ-CGE50VA

Outdoor

MUZ-GE25VA(H)

MUZ-GE35VA(H)

MUZ-GE42VA(H)

MUZ-GE50VA(H)

Function

Cooling

Heating

Cooling

Heating

Cooling

Heating

Cooling

Heating

Cooling

Heating

Power supply

~ /N, 230 V, 50 Hz

Capacity

kW

2.5

3.2

3.5

4.0

4.2

5.4

5.0

5.8

Input

kW

0.545

0.700

0.865

0.955

1.215

1.460

1.515

1.565

Weight

Indoor

kg

10

Outdoor

kg

30

33

36

54

Refrigerant fi lling capacity (R410A)

kg

0.80

1.15

1.15

1.55

IP code

Indoor

IP 20

Outdoor

IP 24

Permissible excessive  
operating pressure

LP ps

MPa

1.64

HP ps

MPa

4.15

Noise level

Indoor (Super High/
High/Med./Low/Silent)

dB(A)

42/36/29/21/19

43/36/30

/22/19

42/36/30

/22/19

46/40/35/30/26

49/44/38

/33/28

48/43/37

/33/28

Outdoor

dB(A)

47

48

47

48

50

51

54

56

Все каталоги и инструкции здесь:

 http

:

//splitoff.ru/tehn-doc.html

Содержание MSZ-CGE22VA

Страница 1: ...rectamente e com segurança certifique se de que lê estas instruções de operação antes da utilização ΟΔΗΓΙΕΣ ΛΕΙΤΟΥΡΓΙΑΣ Για το χρήστη Για να χρησιμοποιήσετε αυτή τη μονάδα σωστά και με ασφάλεια βεβαι ωθείτε ότι έχετε διαβάσει αυτό το εγχειρίδιο οδηγιών πριν από τη χρή ση LIBRETTO D ISTRUZIONI Per gli utenti Per utilizzare correttamente ed in tutta sicurezza questo apparecchio leggere il presente li...

Страница 2: ... electric shock injury or water leakage etc Consult your dealer If the power supply cord is damaged it must be replaced by the manufacturer or its service agent in order to avoid a hazard When installing relocating or servicing the unit make sure that no substance other than the specified refrigerant R410A enters the refrigerant circuit Any presence of foreign substance such as air can cause abnorm...

Страница 3: ... at high speeds during operation When the unit will be unused for a long time disconnect the power plug or turn the breaker OFF The unit may accumulate dirt which may cause overheating or fire Replace all batteries of the remote controller with new ones of the same type Using an old battery together with a new one may cause overheat ing leakage or explosion If the battery fluid comes in contact with...

Страница 4: ...uttons to set the time Each press increases decreases the time by 1 minute 10 minutes when pressed longer Indoor unit Remote controller Outdoor units may be different in appearance 1 Remove the front lid 2 Insert AAA alkaline batteries 3 Install the front lid 4 Press RESET Air cleaning filter Anti Allergy Enzyme Filter option Remote controller holder Signal transmitting section Distance of signal A...

Страница 5: ...ff during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power When timer is set timer setting is cancelled and the unit starts operation when power is resumed If you do not want to use this function please consult the service repre sentative because the setting of the unit needs to be ch...

Страница 6: ...ne manually before starting operation 1 Press during COOL ECONO COOL or HEAT mode to select i save mode 2 Set the temperature fan speed and air flow direction The same setting is selected from the next time by simply pressing Two groups of setting can be saved One for COOL ECONO COOL one for HEAT Select the appropriate temperature fan speed and airflow direction according to your room Normally the ...

Страница 7: ... to perform cooling operation with keeping comfort As a result energy can be saved 1 Press or during operation to set the timer ON timer The unit turns ON at the set time OFF timer The unit turns OFF at the set time or blinks Make sure that the current time is set correctly Page 3 2 Press Increase and Decrease to set the time of timer Each press increases or decreases the set time by 10 minutes Se...

Страница 8: ...old the hinges and pull to remove as shown in the above illustration Wipe with a soft dry cloth or rinse it with water Do not soak it in water for more than two hours Dry it well in shade 3 Install the panel by following the removal proce dure in reverse Close the front panel securely and press the positions indicated by the arrows Hole Hinge Air cleaning filter Anti Allergy Enzyme Filter option Ba...

Страница 9: ...cooling capacity Water leaks from the outdoor unit During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation water condensed on the heat exchanger drips down In the heating operation the defrosting op eration makes water frozen on the outdoor unit melt and drip down White smoke is discharged from the outdoor unit In the he...

Страница 10: ...ower sup ply plug 4 Remove all batteries from the remote controller When using the air conditioner again 1 Clean the air filter Page 7 2 Check that the air inlet and outlet of the indoor and outdoor units are not blocked 3 Check that the earth is connected correctly WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME Indoor Outdoor MUZ GE25 35 42 50VA MUZ GE25 35 42 50VAH Cooling Upper...

Страница 11: ...й разборка или ремонт блока не должны осуществляться пользователем Неправильное обращение с кондиционером может привести к возникновению пожара поражению электротоком травмам и подтеканию воды Проконсультируйтесь с дилером При наличии повреждения в шнуре питания его следует заменить у производителя или его сервисного представителя во избежание опасной ситуации При установке перемещении или техобсл...

Страница 12: ...ой может произойти перегрев утечка или взрыв Если электролит попадет на вашу кожу или одежду тщательно смойте его чистой водой Если электролит попадет в глаза тщательно промойте их чистой водой и сразу же обратитесь к врачу Убедитесь что место хорошо вентилируется при работе блока с легковоспламеняющимися приборами Недостаточная вентиляция может привести к кислородному голо данию Установите выключ...

Страница 13: ... кнопки TIME чтобы установить время При каждом нажатии происхо дит увеличение уменьшение времени на 1 минуту 10 минут при длительном нажатии Внутренний прибор Пульт дистанционного управления Внешний вид устройств предназначенных для использования на улице может отличаться 1 Снимите переднюю крышку 2 Вставьте ще лочные бата рейки типа AAA 3 Установите переднюю крышку 4 Нажмите кнопку RESET Фильтр о...

Страница 14: ...ние прибора было выключено во вре мя его работы функция повторного автозапуска автоматически настраивает прибор на работу в том режиме который был задан с помощью пульта дистанционного управления до отключения электропитания Когда таймер установлен настройка таймера отменяется и блок начинает работу при возобновлении подачи питания Если вы не хотите пользоваться этой функцией обратитесь к представ...

Страница 15: ...еред запуском операции переместите вертикальную заслонку вручную 1 Для выбора режима i save нажмите во время работы кондиционера в режимах COOL ECONO COOL или HEAT 2 Задайте температуру скорость вентилятора и на правление воздушного потока Эта же настройка выбирается в следующий раз путем нажатия Можно сохранять две группы настроек Одну для режима COOL ECONO COOL а вторую для режима HEAT Выберите ...

Страница 16: ...возможность осуществления операции охлаждения и поддерживаются комфортные условия В результате можно экономить электроэнергию 1 Во время операции нажмите или чтобы установить таймер таймер ВКЛЮЧЕНИЯ В заданное время прибор ВКЛЮЧИТСЯ таймер ВЫКЛЮЧЕНИЯ В заданное время при бор ВЫКЛЮЧИТСЯ или мигает Убедитесь что время задано правильно Стр 3 2 Нажмите Увеличить и Уменьшить что бы задать время таймера...

Страница 17: ...ь до тех пор пока она не зафиксируется на месте со щелчком 2 Придерживайте петли и тяните чтобы снять как показано на иллюстрации выше Протирайте мягкой сухой тканью или промывайте водой Не держите ее в воде более двух часов Сушите изделия в тени надлежащим образом 3 Устанавливайте переднюю панель выполняя инс трукции по ее снятию в обратном порядке Надежно закройте переднюю панель и нажмите на об...

Страница 18: ...туре наружного воздуха вентилятор может включаться и выключаться чтобы поддерживать достаточную мощность охлаждения Из наружного прибора выте кает вода При работе в режимах COOL ОХЛАЖ ДЕНИЕ и DRY СУШКА происходит охлаждение труб и трубных соединений что вызывает конденсацию влаги При работе в режиме обогрева конденсат образовавшийся на теплообменнике стекает вниз При работе в режиме обогрева во вр...

Страница 19: ...луатации Охлаждение Внутренний 27 C DB 19 C WB Наружный 35 C DB Обогрев Внутренний 20 C DB Наружный 7 C DB 6 C WB 2 Отдельное использование CGE22 не предусмотрено Данная модель внутреннего прибора предназначена только для мульти системного кондиционера По вопросам технических характеристик мультисистемной моде ли обратитесь к своему дилеру и или см каталог Гарантированный рабочий диапазон DB сухой...

Страница 20: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79F301H04 Все каталоги и инструкции здесь http splitoff ru tehn doc html ...

Отзывы: