The unit should not be installed, relocated, disassembled, altered, 
or repaired by the user.

•  An improperly handled air conditioner may cause fire, electric shock, 

injury, or water leakage, etc. Consult your dealer.

•  If the power supply cord is damaged, it must be replaced by the manu-

facturer or its service agent in order to avoid a hazard.

When installing, relocating, or servicing the unit, make sure that 

no substance other than the specified refrigerant (R32) enters the 

refrigerant circuit.

•  Any presence of foreign substance such as air can cause abnormal 

pressure rise and may result in explosion or injury.

•  The use of any refrigerant other than that specified for the system will 

cause mechanical failure, system malfunction, or unit breakdown. In the 

worst case, this could lead to a serious impediment to securing product 
safety.

This appliance is not intended for use by persons (including children) 

with reduced physical, sensory or mental capabilities, or lack of ex-
perience and knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person responsible 
for their safety.

Children should be supervised to ensure that they do not play with 
the appliance.

 

Do not insert your finger, a stick, or other objects into the air inlet 

or outlet.

•  This may cause injury, since the fan inside rotates at high speeds during 

operation.

 

In case of an abnormal condition (such as a burning smell), stop the 

air conditioner and disconnect the power plug or turn the breaker OFF.

•  A continued operation in the abnormal state may cause a malfunction, 

fire, or electric shock. In this case, consult your dealer.

 

When the air conditioner does not cool or heat, there is a possibility of 
refrigerant leakage. If any refrigerant leakage is found, stop operations 
and ventilate the room well and consult your dealer immediately. If a 
repair involves recharging the unit with refrigerant, ask the service 
technician for details.

•  The refrigerant used in the air conditioner is not harmful. Normally, it 

does not leak. However, if refrigerant leaks and comes in contact with 
fire or heating part of such a fan heater, kerosene heater, or cooking 
stove, it will create harmful gas and there is risk of fire.

The user should never attempt to wash the inside of the indoor unit. 
Should the inside of the unit require cleaning, contact your dealer.

•  Unsuitable detergent may cause damage to plastic material inside 

the unit, which may result in water leakage. Should detergent come in 

contact with electrical parts or the motor, it will result in a malfunction, 

smoke, or fire.

•  The appliance shall be stored in a room without continuously operating 

ignition sources (for example: open flames, an operating gas appliance 
or an operating electric heater).

•  Be aware that refrigerants may not contain an odour.
•  Do not use means to accelerate the defrosting process or to clean the 

appliance, other than those recommended by the manufacturer.

•  Do not pierce or burn.

The indoor unit must be installed in rooms which exceed the floor 

space specified. Please consult your dealer.

This appliance is intended to be used by expert or trained users in 
shops, in light industry and on farms, or for commercial use by lay 
persons.

 CAUTION

Do not touch the air inlet or the aluminum fins of the indoor/outdoor 

unit.

•  This may cause injury.

Do not use insecticides or flammable sprays on the unit.

•  This may cause a fire or deformation of the unit.

Do not expose pets or houseplants to direct airflow.

•  This may cause injury to the pets or plants.

Do not place other electric appliances or furniture under the indoor/
outdoor unit.

•  Water may drip down from the unit, which may cause damage or 

malfunction.

Do not leave the unit on a damaged installation stand.

•  The unit may fall and cause injury.

Do not step on an unstable bench to operate or clean the unit.

•  This may cause injury if you fall down.

Do not pull the power cord.

•  This may cause a portion of the core wire to break, which may cause 

overheating or fire.

Do not charge or disassemble the batteries, and do not throw them 

into a fire.

• 

This may cause the batteries to leak, or cause a fire or explosion.

S

AFETY PRECAUTIONS

Do not operate the unit for more than 4 hours at high humidity (80% 

RH or more) and/or with windows or outside door left open.

•  This may cause the water condensation in the air conditioner, which 

may drip down, wetting or damaging the furniture. 

•  The water condensation in the air conditioner may contribute to growth 

of fungi, such as mold.

Do not use the unit for special purposes, such as storing food, 
raising animals, growing plants, or preserving precision devices 
or art objects.

•  This may cause deterioration of quality, or harm to animals and plants.

Do not expose combustion appliances to direct airflow.

•  This may cause incomplete combustion.

Never put batteries in your mouth for any reason to avoid accidental 
ingestion.

•  Battery ingestion may cause choking and/or poisoning.

Before cleaning the unit, switch it OFF and disconnect the power plug 
or turn the breaker OFF.

•  This may cause injury, since the fan inside rotates at high speeds during 

operation.

When the unit will be unused for a long time, disconnect the power 
plug or turn the breaker OFF.

•  The unit may accumulate dirt, which may cause overheating or fire.

Replace all batteries of the remote controller with new ones of the 
same type.

•  Using an old battery together with a new one may cause overheating, 

leakage, or explosion.

If the battery fluid comes in contact with your skin or clothes, wash 

them thoroughly with clean water.

• 

If the battery fluid comes in contact with your eyes, wash them thoroughly 
with clean water and immediately seek medical attention.

Ensure that the area is well-ventilated when the unit is operated 
together with a combustion appliance.

•  Inadequate ventilation may cause oxygen starvation.

Turn the breaker OFF when you hear thunder and there is a possibility 
of a lightning strike.

•  The unit may be damaged if lightning strikes.

After the air conditioner is used for several seasons, perform inspec-
tion and maintenance in addition to normal cleaning.

•  Dirt or dust in the unit may create an unpleasant odor, contribute to 

growth of fungi, such as mold, or clog the drain passage, and cause 

water to leak from the indoor unit. Consult your dealer for inspection 
and maintenance, which require specialized knowledge and skills.

Do not operate switches with wet hands.

•  This may cause electric shock.

Do not clean the air conditioner with water or place an object that 

contains water, such as a flower vase, on it.

•  This may cause fire or electric shock.

Do not step on or place any object on the outdoor unit.

•  This may cause injury if you or the object falls down.

 IMPORTANT

Dirty filters cause condensation in the air conditioner which will contribute to the 

growth of fungi such as mold. It is therefore recommended to clean air filters every 

2 weeks.

JG79Y723H02.indd   2

2020/10/26   14:05:41

Содержание MSZ-AS90VGD

Страница 1: ...AIR CONDITIONERS English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating instructions before use MSZ AS90VGD INDOOR UNIT JG79Y723H02 indd 1 2020 10 26 14 05 41 ...

Страница 2: ...t expose your body directly to cool air for a prolonged length of time This could be detrimental to your health Meanings of symbols used in this manual Be sure not to do Be sure to follow the instruction Never insert your finger or stick etc Never step onto the indoor outdoor unit and do not put anything on them Danger of electric shock Be careful Be sure to disconnect the power supply plug from t...

Страница 3: ... sprays on the unit This may cause a fire or deformation of the unit Do not expose pets or houseplants to direct airflow This may cause injury to the pets or plants Do not place other electric appliances or furniture under the indoor outdoor unit Water may drip down from the unit which may cause damage or malfunction Do not leave the unit on a damaged installation stand The unit may fall and cause...

Страница 4: ...it it may cause an explosion Earth the unit correctly Do not connect the earth wire to a gas pipe water pipe lightning rod or a telephone earth wire Improper earthing may cause electric shock CAUTION Install an earth leakage breaker depending on the installation location of the air conditioner such as highly humid areas If an earth leakage breaker is not installed it may cause electric shock Ensur...

Страница 5: ...f 2 or more indoor units are installed in proximity to one another an indoor unit that is not intended to be operated may respond to the remote controller i save button Page 8 TIME WEEKLY TIMER set buttons Page 5 11 Outdoor unit WIDE VANE button Page 7 LONG button Page 8 NIGHT MODE button Page 9 Battery replacement indicator Page 5 Remote controller holder Install the remote controller holder in a...

Страница 6: ...atteries with ex pired shelf lives last shorter Press RESET gently using a thin instrument If the RESET button is not pressed the remote controller may not operate correctly Note Press CLOCK gently using a thin instrument Note How to set remote controller exclusively for a particular indoor unit A maximum of 4 indoor units with wireless remote controllers can be used in a room To operate the indoo...

Страница 7: ...e etc Note Operation indicator lamp The operation indicator lamp shows the operation state of the unit Indication Operation state Room temperature The unit is operating to reach the set temperature About 2 C or more away from set tem perature The room temperature is approach ing the set temperature About 1 to 2 C from set temperature Demand Response mode Page 12 Lit Blinking Not lit 1 Press to sta...

Страница 8: ...is selected during COOL DRY the vane automatically moves to the upward position after 0 5 to 1 hour to prevent any condensation from dripping Swing The vane moves up and down intermittently Two short beeps are heard from the indoor unit when set to AUTO Always use the remote controller when changing the direction of air flow Moving the horizontal vanes with your hands causes them to mal function W...

Страница 9: ... setting for COOL ECONO COOL and HEAT This ena bles you to select your preferred setting with a single push of the button A simplified set back function enables to recall the preferred preset setting with a single push of the button Press the button again and you can go back to the previous setting in an instance LONGOPERATION Press to start LONG operation Fan speed increases and the horizontal va...

Страница 10: ... NIGHTMODEOPERATION Press during operation to activate NIGHT MODE The operation indicator lamp dims The beep sound will be disabled except that emitted when the operation is started or stopped Noise level of the outdoor unit will be lower than that mentioned in SPECIFICATIONS Press again to cancel NIGHT MODE Note The cooling heating capacity may drop Noise level of the outdoor unit may not change ...

Страница 11: ...he following order If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power When timer is set timer setting is cancelled and the unit starts operation when power is resumed If you do not want to use this function please consult ...

Страница 12: ...er OFF goes out Note The saved settings will not be cleared when the weekly timer is turned OFF Checking weekly timer setting 1 Press to enter the weekly timer setting mode blinks 2 Press or to view the setting of the particular day or number Press to exit the weekly timer setting Note When all days of the week are selected to view the settings and a different set ting is included among them will ...

Страница 13: ...nues to perform cooling or heating operation during the demand response event but the elec trical energy consumed by the air conditioner in a half hour period is not more than 50 of the total electrical energy that would be consumed if operating at the rated capacity in a half hour period DRM 3 The air conditioner continues to perform cooling or heating operation during the demand response event b...

Страница 14: ... cannot be removed After washing with water dry it well in shade Install all tabs of the air filter Every year Replace it with a new air cleaning filter for best performance Parts Number MAC 1415FT E Air filter Anti Mold filter Clean every 2 weeks Remove dirt by a vacuum cleaner or rinse with water After washing with water dry it well in shade Important Clean the filters regularly for best perform...

Страница 15: ...tdoor unit melt and drip down White smoke is discharged from the outdoor unit In the heating operation vapor generated by the defrosting operation looks like white smoke Symptom Explanation Check points Remote controller The display on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 5 Is the polarity ...

Страница 16: ...ntroller When using the air conditioner again 1 Clean the air filter Page 13 2 Check that the air inlet and outlet of the indoor and outdoor units are not blocked 3 Check that the earth is connected correctly 4 Refer to the PREPARATION BEFORE OPERATION and follow the instructions Page 5 WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME To prevent the effects of a fluorescent lamp ke...

Страница 17: ...JG79Y723H02 indd 16 2020 10 26 14 05 46 ...

Страница 18: ...JG79Y723H02 indd 17 2020 10 26 14 05 46 ...

Страница 19: ...JG79Y723H02 indd 18 2020 10 26 14 05 46 ...

Страница 20: ...HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JG79Y723H02 JG79Y723H02 indd 19 2020 10 26 14 05 46 ...

Отзывы: