En-17
● OPERATING INSTRUCTIONS ●
DB: Dry Bulb
WB: Wet Bulb
Indoor
Outdoor
MUZ-AP25/35/42/50VG MUZ-AP25/35/42/50VGH
Cooling
Upper limit
32°C DB
23°C WB
46°C DB
—
46°C DB
—
Lower limit
21°C DB
15°C WB
-10°C DB
—
-10°C DB
—
Heating
Upper limit
27°C DB
—
24°C DB
18°C WB
24°C DB
18°C WB
Lower limit
20°C DB
—
-15°C DB
-16°C WB
-20°C DB
-21°C WB
Note:
Rating condition
Cooling — Indoor:
27°C DB, 19°C WB
Outdoor: 35°C DB
Heating — Indoor:
20°C DB
Outdoor: 7°C DB, 6°C WB
Guaranteed operating range
S
PECIFICATIONS
Wi-Fi interface
Model
MAC-566IFB-E
Input Voltage
DC12.7 V (from indoor unit)
Power consumption
MAX 2 W
Size H×W×D (mm)
79×44×18.5
Weight (g)
60 (including cable)
Transmitter power level (MAX)
17.5 dBm @IEEE 802.11b
RF channel
1ch ~ 13ch (2412~2472 MHz)
Radio protocol
IEEE 802.11b/g/n (20)
Encryption
AES
Authentication
WPA2-PSK
Software Version
XX.00
For Declaration of Conformity, please go to the website below.
http://www.melcloud.com/Support
Model
Indoor
MSZ-AP25VG(K)
MSZ-AP35VG(K)
MSZ-AP42VG(K)
MSZ-AP50VG(K)
Outdoor
MUZ-AP25VG(H)
MUZ-AP35VG(H)
MUZ-AP42VG(H)
MUZ-AP50VG(H)
Function
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Power supply
~ /N, 230 V, 50 Hz
Capacity
kW
2.5
3.2
3.5
4.0
4.2
5.4
5.0
5.8
Input
kW
0.60
0.78
0.99
1.03
1.30
1.49
1.55
1.60
Weight
Indoor
kg
10.5
Outdoor
kg
31
31
35
40
Refrigerant fi lling capacity (R32)
kg
0.55
0.55
0.70
1.00
IP code
Indoor
IP 20
Outdoor
IP 24
Permissible excessive
operating pressure
LP ps
MPa
2.77
HP ps
MPa
4.17
Noise level
Indoor (Super High/
High/Med./Low/Silent) dB(A)
42/36/30/
24/19
45/39/34/
24/19
42/36/30/
24/19
45/38/31/
24/19
42/38/34/
29/21
45/40/35/
29/21
44/40/36/
33/28
48/43/38/
33/28
Outdoor
dB(A)
47
48
49
50
50
51
52
52
JG79Y352H02_en.indd 17