background image

En-2

S

AFETY PRECAUTIONS

 CAUTION

Do not touch the air inlet or the aluminum fi ns of the indoor/

outdoor unit.

•  This may cause injury.

Do not use insecticides or fl ammable sprays on the unit.

•  This may cause a fi re or deformation of the unit.

Do not expose pets or houseplants to direct airfl ow.

•  This may cause injury to the pets or plants.

Do not place other electric appliances or furniture under the 

indoor/outdoor unit.

•  Water may drip down from the unit, which may cause damage 

or malfunction.

Do not leave the unit on a damaged installation stand.

•  The unit may fall and cause injury.

Do not step on an unstable bench to operate or clean the unit.

•  This may cause injury if you fall down.

Do not pull the power cord.

•  This may cause a portion of the core wire to break, which may 

cause overheating or fi re.

Do not charge or disassemble the batteries, and do not 

throw them into a fi re.

•  This may cause the batteries to leak, or cause a fi re or explosion.

Do not operate the unit for more than 4 hours at high humidity 

(80% RH or more) and/or with windows or outside door left open.

•  This may cause the water condensation in the air conditioner, 

which may drip down, wetting or damaging the furniture. 

•  The water condensation in the air conditioner may contribute 

to growth of fungi, such as mold.

Do not use the unit for special purposes, such as storing 

food, raising animals, growing plants, or preserving preci-

sion devices or art objects.

•  This may cause deterioration of quality, or harm to animals 

and plants.

Do not expose combustion appliances to direct airfl ow.

•  This may cause incomplete combustion.

Never put batteries in your mouth for any reason to avoid 

accidental ingestion.

•  Battery ingestion may cause choking and/or poisoning.

Before cleaning the unit, switch it OFF and disconnect the 

power plug or turn the breaker OFF.

•  This may cause injury, since the fan inside rotates at high 

speeds during operation.

When the unit will be unused for a long time, disconnect the 

power plug or turn the breaker OFF.

•  The unit may accumulate dirt, which may cause overheating or fi re.

 WARNING

Consult your dealer for installing the air conditioner. 

•  It should not be installed by the user since installation requires 

specialized knowledge and skills. An improperly installed air 

conditioner may cause water leakage, fi re, or electric shock.

Provide a dedicated power supply for the air conditioner.

•  A non-dedicated power supply may cause overheating or fi re.

Do not install the unit where fl ammable gas could leak.

•  If gas leaks and accumulates around the outdoor unit, it may 

cause an explosion.

Earth the unit correctly.

•  Do not connect the earth wire to a gas pipe, water pipe, light-

ning rod, or a telephone earth wire. Improper earthing may 

cause electric shock.

 CAUTION

Install an earth leakage breaker depending on the installation 

location of the air conditioner (such as highly humid areas).

•  If an earth leakage breaker is not installed, it may cause electric 

shock.

Ensure that the drain water is properly drained.

•  If the drain passage is improper, water may drip down from 

the indoor/outdoor unit, wetting and damaging the furniture.

In case of an abnormal condition

  Immediately stop operating the air conditioner and consult your dealer.

Replace all batteries of the remote controller with new ones 

of the same type.

•  Using  an  old  battery  together  with  a  new  one  may  cause 

overheating, leakage, or explosion.

If the battery fl uid comes in contact with your skin or clothes, 

wash them thoroughly with clean water.

•  If the battery fl uid comes in contact with your eyes, wash them 

thoroughly  with  clean  water  and  immediately  seek  medical 

attention.

Ensure that the area is well-ventilated when the unit is oper-

ated together with a combustion appliance.

•  Inadequate ventilation may cause oxygen starvation.

Turn the breaker OFF when you hear thunder and there is a 

possibility of a lightning strike.

•  The unit may be damaged if lightning strikes.

After the air conditioner is used for several seasons, perform 

inspection and maintenance in addition to normal cleaning.

•  Dirt or dust in the unit may create an unpleasant odor, con-

tribute to growth of fungi, such as mold, or clog the drain pas-

sage, and cause water to leak from the indoor unit. Consult 

your  dealer  for  inspection  and  maintenance,  which  require 

specialized knowledge and skills.

Do not operate switches with wet hands.

•  This may cause electric shock.

Do not clean the air conditioner with water or place an object 

that contains water, such as a fl ower vase, on it.

•  This may cause fi re or electric shock.

Do not step on or place any object on the outdoor unit.

•  This may cause injury if you or the object falls down.

For installation

 IMPORTANT

Dirty fi lters cause condensation in the air conditioner which will con-

tribute to the growth of fungi such as mold. It is therefore recommended 

to clean air fi lters every 2 weeks.

 WARNING

  

When the air conditioner does not cool or heat, there is a 

possibility of refrigerant leakage. If any refrigerant leak-

age is found, stop operations and ventilate the room well 

and consult your dealer immediately. If a repair involves 

recharging the unit with refrigerant, ask the service techni-

cian for details.

•  The refrigerant used in the air conditioner is not harmful. 

Normally, it does not leak. However, if refrigerant leaks and 

comes in contact with fi re or heating part of such a fan heater, 

kerosene heater, or cooking stove, it will create harmful gas 

and there is risk of fi re.

The user should never attempt to wash the inside of the 

indoor unit. Should the inside of the unit require cleaning, 

contact your dealer.

•  Unsuitable detergent may cause damage to plastic material 

inside the unit, which may result in water leakage. Should 

detergent come in contact with electrical parts or the motor, 

it will result in a malfunction, smoke, or fi re.

•  The appliance shall be stored in a room without continuously 

operating  ignition  sources  (for  example:  open  fl ames,  an 

operating gas appliance or an operating electric heater).

•  Be aware that refrigerants may not contain an odour.

•  Do not use means to accelerate the defrosting process or 

to clean the appliance, other than those recommended by 

the manufacturer.

•  Do not pierce or burn.

The unit must be installed in rooms which exceed the fl oor

 

space specifi ed below.

• GN35: 1.7 m²

• GN42: 1.7 m²

JG79Y270H02_en.indd   2

2017/04/28   13:32:57

Содержание MSY-GN25VF

Страница 1: ...CTIONS For user To use this unit correctly and safely be sure to read these operating instructions before use SPLIT TYPE AIR CONDITIONERS INDOOR UNIT MSY GN25VF MSY GN35VF MSY GN42VF JG79Y270H02_Cover indd 1 2017 04 27 8 38 48 ...

Страница 2: ...sure to turn the breaker OFF or disconnect the power plug Do not expose your body directly to cool air for a prolonged length of time This could be detrimental to your health The unit should not be installed relocated disassembled altered or repaired by the user An improperly handled air conditioner may cause fire electric shock injury or water leakage etc Consult your dealer If the power supply co...

Страница 3: ...tdoor unit wetting and damaging the furniture In case of an abnormal condition Immediately stop operating the air conditioner and consult your dealer Replace all batteries of the remote controller with new ones of the same type Using an old battery together with a new one may cause overheating leakage or explosion If the battery fluid comes in contact with your skin or clothes wash them thoroughly ...

Страница 4: ...ies first 3 Install the front lid 4 Press RESET Remote controller holder Signal transmitting section Distance of signal About 6 m Beep s is are heard from the indoor unit when the signal is received Operation display section OFF ON stop operate button Temperature buttons Page 4 Battery replacement indicator Page 3 Operation select button Page 4 ECONO COOL button Page 6 FAN speed control button Page...

Страница 5: ...operation 2 Press to select operation mode Each press changes mode in the following order 3 Press or to set the temperature Each press raises or lowers the temperature by 1 C Press to stop the operation The same setting is selected the next time by simply pressing Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically st...

Страница 6: ...ing Swing The vane moves up and down intermittently To change the horizontal airflow direction Move the vertical vane manually before starting operation 1 Press during COOL or ECONO COOL mode to select i save mode 2 Set the temperature fan speed and airflow direction The same setting is selected from the next time by simply pressing One group of setting can be saved Select the appropriate temperatur...

Страница 7: ...s possible to perform cooling operation with keeping comfort As a result energy can be saved 1 Press or during operation to set the timer ON timer The unit turns ON at the set time OFF timer The unit turns OFF at the set time or blinks Make sure that the current time is set correctly Page 3 2 Press Increase and Decrease to set the time of timer Each press increases or decreases the set time by 10 ...

Страница 8: ...tribute to the growth of fungi such as mold It is therefore recommended to clean air filters every 2 weeks Pull to remove from the air filter 1 Lift the front panel until a click is heard 2 Hold the hinges and pull to remove as shown in the illustration above Wipe with a soft dry cloth or rinse it with water Do not soak it in water for more than two hours Dry it well in shade 3 Install the front pan...

Страница 9: ... signal Are the batteries exhausted Page 3 Is the polarity of the batteries correct Page 3 Are any buttons on the remote controller of other electric appliances being pressed Symptom Explanation Check points Does not cool The room cannot be cooled sufficiently Is the temperature setting appropriate Page 4 Is the fan setting appropriate Please change fan speed to High or Super High Page 5 Are the fil...

Страница 10: ...t temperature set or FAN mode for 3 to 4 hours Page 4 This dries the inside of the unit Moisture in the air conditioner contributes to growth of fungi such as mold 2 Press to stop the operation 3 Turn off the breaker and or disconnect the power sup ply plug 4 Remove all batteries from the remote controller When using the air conditioner again 1 Clean the air filter Page 7 2 Check that the air inlet...

Страница 11: ...JG79Y270H02_Cover indd 4 2017 04 27 8 39 34 ...

Страница 12: ...HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JG79Y270H02 JG79Y270H02_Cover indd 2 2017 04 27 8 38 48 ...

Отзывы: