7
3-1. OPERATING RANGE
(1) POWER SUPPLY
Rated voltage
Guaranteed voltage (V)
Indoor unit
208/230 V
1 phase
60 Hz
Min. 187
208
230 Max. 253
(2) OPERATION
Mode
Condition
Intake air temperature (°F)
Indoor
DB
WB
Cooling
Standard temperature
80
67
Maximum temperature
90
73
Minimum temperature
67
57
Maximum humidity
78%
Heating
Standard temperature
70
60
Maximum temperature
80
67
Minimum temperature
70
60
3-2. OUTLET AIR SPEED AND COVERAGE
● The air coverage is the figure up to the
position where the air speed is 1 ft./s.,
when air is blown out horizontally from
the unit properly at the High speed
position.
The coverage should be used only as a
general guideline since it varies accord-
ing to the size of the room and furniture
arranged inside the room.
Model
Mode
Function
Airflow
(CFM)
Air speed
(ft./s.)
Coverage
(ft.)
MSZ-GL06NA
HEAT
Dry
406
20.6
29.5
COOL
Dry
321
16.3
23.5
Wet
286
14.5
21.0
MSZ-GL09NA
MSY-GL09NA
HEAT
Dry
406
20.6
29.5
COOL
Dry
321
16.3
23.5
Wet
286
14.5
21.0
MSZ-GL12NA
MSY-GL12NA
HEAT
Dry
406
20.6
29.5
COOL
Dry
321
16.3
23.5
Wet
286
14.5
21.0
MSZ-GL15NA
MSY-GL15NA
HEAT
Dry
463
23.4
33.5
COOL
Dry
420
21.3
30.5
Wet
385
19.5
28.0
MSZ-GL18NA
MSY-GL18NA
HEAT
Dry
646
29.5
44.0
COOL
Dry
646
29.5
44.0
Wet
581
26.5
39.7
MSZ-GL24NA
MSY-GL24NA
HEAT
Dry
738
18.0
36.9
COOL
Dry
738
18.0
36.9
Wet
661
16.1
33.2
OBH732D