background image

En-3

● OPERATING INSTRUCTIONS ●

Display section

Operation indicator 

lamp

Remote control 

receiving section

Emergency 

operation switch 

 Page 4 

Air inlet  (back and side)

Piping

Drainage hose

Air outlet

Drain outlet

Remote controller 
holder

Signal transmitting 

section

Distance of signal : 

About 6 m

Beep(s) is (are) heard 

from the indoor unit when 

the signal is received.

Operation display 

section

ON/OFF

(operate/stop) 

button

Temperature buttons

 Page 4 

Operation 

select button 

 Page 4 

ECONO 

COOL 

button 

 Page 5 

FAN speed 

control button 

 Page 5 

Off-timer button 

 Page 5 

On-timer button 

 Page 5 

VANE 

control button 

 Page 5 

TIME set buttons 

 Pages 3, 5 

  Increase time

  Decrease time

CLOCK button 

 Page 3 

RESET button 

 Page 3 

Lid

Slide down to open

•  Install the remote control-

ler holder to a place where 

the signal can be received 

by the indoor unit.

Use the remote controller provided with the unit only.

Do not use other remote controllers.

Horizontal vane

Vertical vane

Air outlet

Fan

Air fi lter

(Catechin 

air fi lter)

Air inlet

Heat exchanger

Front panel

Air cleaning fi lter 

(Anti-Allergy Enzyme Filter)

Fan guard

Outdoor unit

N

AME OF EACH PART

P

REPARATION BEFORE OPERATION

Indoor unit

Remote controller

Appearance of the outdoor unit may differ from some models.

RESET

CLOCK

•   Make sure the polarity of the batteries is correct.

•  

Do not use manganese batteries. The remote controller could malfunction.

•   Do not use rechargeable batteries.

•   Replace all batteries with new ones of the same type.

•  Batteries can be used for approximately 1 year. However, batteries with 

expired shelf lives last shorter.

•  Press RESET gently using a thin instrument.

  If the RESET button is not pressed, the remote controller may not operate 

correctly.

Before operation:

 Insert the power supply plug into the power outlet and/or turn the breaker on.

•  Press CLOCK gently using a thin instrument.

Installing the remote controller batteries

Setting current time

1.

 Press CLOCK

3.

 Press CLOCK again

2.

 Press the TIME buttons to set the 

time.

 

Each press increases/decreases 

the time by 1 minute (10 minutes 

when pressed longer)

1.

 

Remove the front lid

2.

 Insert AAA

alkaline batteries

3.

 Install the front lid

4.

 

Press RESET

RESET

CLOCK

SG79F322H03_en.indd   3

2009/06/26   10:54:38

Содержание MSY-GC25VA

Страница 1: ...SPLIT TYPE AIR CONDITIONERS INDOOR UNIT MSY GC25VA MSY GC35VA English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use ...

Страница 2: ...handling could cause serious hazard depending on the conditions Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside rotates at high speeds during operation In case of an abnormal condition such as a burning smell stop the air conditioner and disconnect the power plug or turn the breaker OFF A continued operation in the abnormal ...

Страница 3: ...hear thunder and there is a possibility of a lightning strike The unit may be damaged if lightning strikes After the air conditioner is used for several seasons per form inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor con tribute to growth of fungi such as mold or clog the drain pas sage and cause water to leak from the indoor unit C...

Страница 4: ...lter Air inlet Heat exchanger Front panel Air cleaning filter Anti Allergy Enzyme Filter Fan guard Outdoor unit NAME OF EACH PART PREPARATION BEFORE OPERATION Indoor unit Remote controller Appearance of the outdoor unit may differ from some models R E S E T C L O C K Make sure the polarity of the batteries is correct Do not use manganese batteries The remote controller could malfunction Do not use ...

Страница 5: ...mperature About 1 to 2 C from set temperature Lighted Not lighted Emergency operation When the remote controller cannot be used Emergency operation can be activated by pressing the emergency operation switch E O SW on the indoor unit Each time the E O SW is pressed the operation changes in the following order 1 Press to start the operation 2 Press to select operation mode Each press changes mode i...

Страница 6: ...ow direction Move the vertical vane manually before starting operation Press during COOL mode page 4 to start ECONO COOL operation The unit performs swing operation vertically in various cycle according to the temperature of the unit Set temperature is set 2 C higher auto matically Press again to cancel ECONO COOL operation Pressing also cancels ECONO COOL operation What is ECONO COOL Swing air flo...

Страница 7: ...st performance and to reduce power consumption Moisture in the air conditioner for a long time contributes to growth of fungi such as mold To prevent fungi growth set to the highest temperature in manual COOL mode and operate for 3 or 4 hours to dry out the inside of the unit Air outlet and Fan before cleaning make sure that the fan is stopped Pull to remove from the air filter Air filter Catechin a...

Страница 8: ...ints Remote controller The display on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 3 Is the polarity of the batteries correct Page 3 Are any buttons on the remote controller of other electric appliances being pressed Does not cool The room cannot be cooled sufficiently Is the temperature setting app...

Страница 9: ...cent lamp Keep a space to prevent the pic ture distortion or the noise 1 m or more Radio 100 mm or more Well ventilated dry place 100 mm or more TV Cordless phone or Portable phone 3 m or more 1 m or more The installation location of the outdoor unit should be at least 3 m away from the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor u...

Страница 10: ......

Страница 11: ......

Страница 12: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79F322H03 ...

Отзывы: