29
MICROPROCESSOR CONTROL
8
WIRELESS REMOTE CONTROLLER
ON/OFF
RESET
TOO
WARM
TOO
COOL
ECONO COOL
POWERFUL COOL
SELECT
FAN
VANE
TIME
MODE
h
I FEEL COOL
DRY
HEAT
Signal transmitting section
Operation display section
TEMPERATURE buttons
VANE CONTROL button
TIME SET button
RESET button
FAN SPEED CONTROL button
ECONO COOL button
POWERFUL COOL button
OPERATION SELECT button
TIMER MODE SELECT button
OPERATE/STOP (ON/OFF) button
Remote controller holder
Once the operation mode are set, the same operation mode
can be repeated by simply turning the OPERATE/STOP button
ON. Indoor unit receives the signal with a beep tone.
When the system turns off, 3-minute time delay will operate to
protect system from overload and compressor will not restart
for 3 minutes.
COOL mode of
"I FEEL CONTROL"
DRY mode of
"I FEEL CONTROL"
HEAT mode of
"I FEEL CONTROL"
Initial room temperature
25
:
or more
23
:
to 25
:
less than 23
:
Mode
8-1. “I FEEL CONTROL” (
) OPERATION
(1) Press OPERATE/STOP(ON/OFF) button on the remote
controller. OPERATION INDICATOR lamp of the indoor
unit turns on with a beep tone.
(2) Select “I FEEL CONTROL”(
) mode with the OPERA-
TION SELECT button.
(3) The operation mode is determined by the room tempera-
ture at start-up of the operation.
lighted
not lighted
Approx. 2
:
or more
Difference
between target
temperature
and room
temperature
Approx. 2
:
or less
This shows that the
air conditioner is
operating to reach
the target temperature.
Please wait unit the
target temperature is
obtained.
This shows that the
room temperature is
approaching the
target temperature.
Operation state
Indication
Operation Indicator
Operation Indicator lamp
The operation indicator at the right side of the indoor
unit indicates the operation state.
• The following indication applies regardless of shape
of the indicator.
INDOOR UNIT DISPLAY SECTION
●
Once the mode is fixed, the mode does not change by
room temperature afterwards.
●
Under the ON-TIMER (
) operation, mode is deter-
mined according to the room temperature at set time the
operation starts.
●
When the system is stopped on the remote controller
and restarted within 2 hours in “I FEEL CONTROL” (
)
mode, the system operates in previous mode automati-
cally regardless of the room temperature.
Example
Previous operation
COOL mode of
“I FEEL CONTROL”
or COOL mode
Restart
COOL mode of
“I FEEL CONTROL”
Operation time chart
When the system is restarted after 2 hours and more, the
operation mode is determined by the room temperature
at start-up of the operation.
Example
Previous operation
COOL mode of
“I FEEL CONTROL”
or COOL mode
Restart
COOL or DRY or
HEAT mode of “I FEEL
CONTROL” that deter-
mined by room tem-
perature at start-up of
the operation.
Operation time chart
MSH-XV07UV -
MSH-XV12UV -
MSH-XV09UV -
E1
E1
E1
MUH-XV07UV -
MUH-XV12UV -
MUH-XV09UV -
E1
E1
E1