12
Indoor
unit
w
Max. Height
difference 5m
Height difference should be within
5m regardless of which unit,
indoor or outdoor position is high.
Outdoor unit
Refrigerant Piping
Max.length
A
MAX. HEIGHT DIFFERENCE
ADDITIONAL REFRIGERANT CHARGE(R22 : g)
MAX. REFRIGERANT PIPING LENGTH
Refrigerant piping
Max. length : m
A
10
15
Indoor unit
Gas 0.43
Liquid 0.5
Gas
9.52
12.7
Liquid
6.35
Outdoor unit
Gas 0
Liquid 0
Piping size O.D : mm
Length of connecting pipe : m
Model
MSH-XV07UV -
E1
MUH-XV07UV -
E1
MSH-XV09UV -
E1
MUH-XV09UV -
E1
MSH-XV12UV -
E1
MUH-XV12UV -
E1
Calculation : Xg=50g/mx(Refrigerant piping length(m)-7)
MSH-XV07UV -
E1
MUH-XV07UV -
E1
MSH-XV09UV -
E1
MUH-XV09UV -
E1
MSH-XV12UV -
E1
MUH-XV12UV -
E1
Outdoor unit precharged
770
870
1100
15m
400
7m
0
10m
150
Model
Refrigerant piping length (one way)
Unit:mm
MSH-XV12UV -
E1
MUH-XV12UV -
E1
INDOOR UNIT
OUTDOOR UNIT
(with heat insulator)
(with heat insulator)
Refrigerant pipe
[
12.7
4-way valve
Muffler
Stop valve
(with service port)
Strainer
Refrigerant pipe
[
6.35
Stop valve
Capillary tube
[
3.0
O
[
1.6
O
700
Check valve
Refrigerant flow in cooling
Refrigerant flow in heating
Defrost
thermistor
RT61
Outdoor
heat
exchanger
Room temperature
thermistor
RT11
Indoor coil
thermistor
RT12
Capillary tube
[
3.0
O
[
1.8
O
300
Flared connection
Flared connection
Compressor
Indoor
heat
exchanger
R.V. coil
heating ON
cooling OFF
Capillary tube
[
3.0
O
[
1.4
O
500(2pcs)
Strainer
OB294--1.qxp 02.1.26 1:52 PM Page 12