En-4

 I FEEL mode

The unit selects the operation mode according to the room temperature 

when I FEEL is selected. When the room temperature is higher than 25°C, 

COOL is selected (set temperature: 24°C). When the room temperature 

is lower than 25°C, DRY is selected. However, when operation is stopped 

and then started within 2 hours, the mode which has been selected previ-

ously is operated.

Note: 

During COOL operation, the set temperature may not be changed when 

the room temperature is more than 2°C higher than the set temperature. 

In this case, please wait until the room temperature drops to within 2°C of 

the set temperature.

 COOL mode

Enjoy cool air at your desired temperature. 

  DRY mode

Dehumidify your room. The room may be cooled slightly. 

Temperature cannot be set during DRY mode.

 FAN mode

Circulate the air in your room.

Operation indicator lamp

The operation indicator lamp shows the operation state of the unit.

Indication

Operation state

Room temperature

The unit is operating to reach the set 

temperature

About 2°C or more  

away from set tem-

perature

The room temperature is approach-

ing the set temperature

About 1 to 2°C from 

set temperature

  Lighted 

 

Not lighted

Emergency operation

When the remote controller cannot be used...

Emergency operation can be activated by pressing the emergency operation 

switch (E.O.SW) on the indoor unit.

Each time the E.O.SW is pressed, the operation changes 

in the following order:

1

Press 

 to start the operation.

2

Press 

 to select operation mode. Each press 

changes mode in the following order:

3

Press 

 or 

 to set the temperature.

Each press raises or lowers the temperature by 1°C.

Press 

 to stop the operation.

•  The same setting is selected the next time by simply pressing

 

.

Auto restart function

If a power failure occurs or the main power is turned off during operation, “Auto 

restart function” automatically starts operation in the same mode as the one 

set with the remote controller just before the shutoff of the main power. When 

timer is set, timer setting is cancelled and the unit starts operation when power 

is resumed.

If you do not want to use this function, please consult the service repre-

sentative because the setting of the unit needs to be changed.

S

ELECTING OPERATION MODES

(I FEEL)

(COOL)

(DRY)

(FAN)

Operation indicator lamp

Set temperature : 24°C

Fan speed : Medium

Horizontal vane : Auto

Emergency COOL

Stop

Note:

The fi rst 30 minutes of operation is test run. Temperature 

control does not work, and fan speed is set to High.

SG79F708H01_en.indd   4

2012/11/14   10:00:08

Содержание MS-GJ09VA

Страница 1: ...English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating instructions before use SPLIT TYPE AIR CONDITIONERS INDOOR UNIT MS GJ09VA MS GJ13VA ...

Страница 2: ...ime This could be detrimental to your health The unit should not be installed relocated disassembled altered or repaired by the user An improperly handled air conditioner may cause fire electric shock injury or water leakage etc Consult your dealer If the power supply cord is damaged it must be replaced by the manufacturer or its service agent in order to avoid a hazard When installing relocating o...

Страница 3: ...lean water If the battery fluid comes in contact with your eyes wash them thoroughly with clean water and immediately seek medical attention Ensure that the area is well ventilated when the unit is oper ated together with a combustion appliance Inadequate ventilation may cause oxygen starvation Turn the breaker OFF when you hear thunder and there is a possibility of a lightning strike The unit may ...

Страница 4: ...remote controller holder in a place where the signal can be received by the indoor unit Only use the remote controller provided with the unit Do not use other remote controllers If two or more indoor units are installed in proximity to one another an indoor unit that is not intended to be operated may respond to the remote controller Outdoor unit Installing the remote controller batteries NAME OF ...

Страница 5: ...from set temperature Lighted Not lighted Emergency operation When the remote controller cannot be used Emergency operation can be activated by pressing the emergency operation switch E O SW on the indoor unit Each time the E O SW is pressed the operation changes in the following order 1 Press to start the operation 2 Press to select operation mode Each press changes mode in the following order 3 P...

Страница 6: ...TION ADJUSTMENT Airflow direction AUTO The vane is set to the most efficient airflow direction horizontal position Manual For efficient air conditioning select the upper position for COOL DRY If the lower position is selected during COOL DRY the vane automatically moves to the horizontal position after 0 5 to 1 hour to prevent any condensation from dripping Swing The vane moves up and down intermitt...

Страница 7: ...er Each press changes timer mode in the following order 2 Press to set the time of timer Each press increases or decreases the set time by 1 hour Press until TIMER RELEASE is selected to release timer Note ON and OFF timers can not be used in combination If power failure occurs while ON OFF timer is set see page 4 Auto restart function OFF TIMER ON TIMER TIMER OPERATION ON OFF TIMER TIMER RELEASE ...

Страница 8: ...ncludes a platinum nanoparti cle The particles are incorporated into the filter material which results in providing semi permanent antibacterial and deodorizing characteris tics for the filter Nano platinum surpasses the catechin a bioflavonoid that is found in green tea in performance Nano platinum filter uses this compound not only to improve air quality but also to eliminate bacteria and viruses Th...

Страница 9: ...ations pipe or pipe connecting sections are cooled and this causes water to condense Remote controller The display on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 3 Is the polarity of the batteries correct Page 3 Are any buttons on the remote controller of other electric appliances being pressed Do...

Страница 10: ...on of the outdoor unit should be at least 3 m away from the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception 1 Set to the highest temperature in manual COOL mode and operate for 3 to 4 hours Page 4 This dries the inside ...

Страница 11: ... เครื องอย างไม ถูกวิธี อาจเป นสาเหตุให เกิดอันตรายอย าง รุนแรง ขึ นอยู กับสภาพการใช งานนั นๆ ไม ควรให บุคคล รวมทั งเด กเล ก ที มีสภาพร างกายไม แข งแรง สภาพ การรับรู หรือจิตใจไม ปกติ หรือขาดประสบการณ และความรู ความเข าใจ นำอุปกรณ น ไปใช งาน เว นแต จะอยู ในการควบคุมดูแล หรือได รับคำแนะ นำในการใช งานจากผู ที รับผิดชอบต อความปลอดภัยของบุคคลนั นๆ ได เด กเล กควรได รับการดูแลเพื อป องกันไม ให นำอุปกรณ น...

Страница 12: ...ของท าน ควรล างออกให หมดด วยน ำสะอาด หากของเหลวในแบตเตอรี สัมผัสกับดวงตา ควรล างออกให หมดด วย น ำสะอาด และพบแพทย โดยทันที ควรตรวจให แน ใจว าพื นที นั นจะมีการระบายอากาศที ดีขณะที เครื อง ปรับอากาศทํางานพร อมกับเครื องใช ที มีการเผาไหม การระบายอากาศที ไม ดีเพียงพอ อาจทําให เกิดภาวะขาดออกซิเจนได สับเบรกเกอร ลง หากท านได ยินเสียงฟ าร อง และมีความเป นไปได ที จะ เกิดฟ าผ า เครื องอาจชํารุด หากโดนฟ าผ า...

Страница 13: ...ในบ านที ไม ได ใช งานอาจตอบรับการสั งงานจากรีโมทคอนโทรลได การใส แบตเตอรี ในรีโมทคอนโทรล ชื อของส วนประกอบต างๆ เสียบปลั กไฟเข ากับเต ารับ และ หรือสับเบรกเกอร ขึ น การเตรียมตัวก อนใช งาน 1 ถอดฝาด านหลังออก 2 ใส แบตเตอรี อัลคาไลน ขนาด AAA ด านขั วลบก อน 3 ใส ฝาด านหลังกลับเข าไป เครื องภายในบ าน รีโมทคอนโทรล ปุ มระบบความเย นแบบ POWERFUL COOL หน า 6 4 กดปุ ม RESET เครื องภายนอกบ าน ลักษณะของเครื องภา...

Страница 14: ...ว าอุณหภูมิที ตั งไว 2 C ในกรณ น โปรดรอจนกระทั งอุณหภูมิห องลดลงถึง ระดับที ต างจากอุณหภูมิที ตั งไว ไม เกิน 2 C โหมด COOL เพลิดเพลินกับอากาศเย นในระดับอุณหภูมิที ท านต องการ โหมด DRY เป นการลดความชื นในห อง อุณหภูมิห องจะลดลงเล กน อย ไม สามารถตั งอุณหภูมิได ในระหว างการใช โหมด DRY โหมด FAN เป นการหมุนเวียนอากาศภายในห องของท าน ระบบการทำงานฉุกเฉิน เมื อไม สามารถใช งานรีโมทคอนโทรลได ท านสามารถใช ระ...

Страница 15: ...าน เมื อเลือกการทำงานแบบ อัตโนมัติ ทิศทางลม อัตโนมัติ บานเกล ดจะถูกตั งไว ที ทิศทางลมที มีประสิทธิภาพสูงสุด ตำแหน งแนวราบ ปรับเอง เพื อประสิทธิภาพที ดีในการปรับอากาศ ให เลือกตำแหน งสูงขึ น ในการทำงานแบบ COOL DRY หากมีการเลือกตำแหน งด าน ล างระหว าง COOL DRY ทิศทางลมจะเลื อนไปตำแหน ง แนวนอนโดยอัตโนมัติหลังจาก 0 5 ถึง 1 ชั วโมง เพื อป องกัน การควบแน นจากหยดน ำ สวิง บานเกล ดจะเลื อนขึ นและลงเป นระยะๆ...

Страница 16: ...วลาเปลี ยนไปตามลำดับดังน 2 กดปุ ม เพื อตั งเวลาเป ด ป ด เมื อกดปุ มแต ละครั ง เวลาที ตั งไว จะเพิ มขึ นลดลงครั งละ 1 ชั วโมง กดปุ ม จนกระทั ง TIMER RELEASE ปรากฏขึ น หมายเหตุ การตั งเวลาเป ด ON และป ด OFF ไม สามารถใช ร วมกันได หากกระแสไฟขัดข องในขณะที โปรแกรมมีการตั งเวลาเป ดป ด ON OFF ทำงานอยู ดู หน า 4 ฟ งก ชันการเริ มต นการทำงานใหม โดยอัตโนมัติ การตั งเวลา OFF การตั งเวลา ON การตั งเวลาเป ด ป ด...

Страница 17: ...ทำให แห ง ห ามใช น ำที มีความร อนเกิน 50 C คำแนะนำ แผ นกรองอากาศ แผ นกรองนาโนแพลตินัม ทำความสะอาดทุก 2 สัปดาห กำจัดสิ งสกปรกด วยเครื องดูดฝุ น หรือล างออกด วยน ำ ตากให แห งในที ร มก อนที จะติดตั ง แผ นกรองนาโนแพลตินัม คืออะไร นาโนแพลตินัมคืออนุภาคของเซรามิคที มีอนุภาคของแพลตินัมซึ งมีขนาดเล กใน ระดับนาโนรวมอยู ด วย อนุภาคที รวมอยู ในวัสดุของแผ นกรองน จะช วยให แผ นกรอง มีคุณลักษณะต อต านแบคทีเรียแล...

Страница 18: ...ารทำงานของตัวเครื อง เครื องภายนอกบ าน เกิดน ำรั วจากเครื องภายนอกบ าน ระหว างการทำงานแบบ COOL ทำความเย น และ DRY ลดความชื น ท อและจุดเชื อมท อต างๆ จะเย นตัวทำให ไอน ำเกิดการกลั นตัวได รีโมทคอนโทรล ไม มีผลแสดงการทำงานที รีโมท คอนโทรลหรือไม ชัด เครื องภายใน บ านไม ตอบสนองต อสัญญาณของ รีโมทคอนโทรล แบตเตอรี หมดหรือไม หน า 3 ใส แบตเตอรี ถูกขั วหรือไม หน า 3 มีการกดปุ มรีโมทคอนโทรลของเครื องใช ไฟฟ า ช...

Страница 19: ...ตั งเครื องภายนอกห างจากเสาอากาศของวิทยุและโทรทัศน ไม ต ำกว า 3 เมตร ในบริเวณที มีสัญญาณอ อนมาก ในระยะข างต นอาจ เกิดสัญญาณการทำงานของเครื องปรับอากาศแทรกในวิทยุหรือโทรทัศน ได ในกรณ เช นน ให ทำการเพิ มระยะห างจนกว าจะปราศจากสัญญาณ แทรกรบกวน 1 ตั งอุณหภูมิไว ที ระดับสูงสุดในโหมด manual COOL เป นเวลา 3 ถึง 4 ชั วโมง หน า 4 เป นการขจัดความชื นภายในเครื อง ความชื นในเครื องปรับอากาศก อให เกิดสภาพที เห...

Страница 20: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79F708H01 ...

Отзывы: