18
(7) SWING ( ) mode
By selecting SWING mode with VANE CONTROL button, the horizontal vane swings vertically.
(8) ECONO COOL ( ) operation (ECONOmical operation)
When ECONO COOL button is pressed in COOL mode, set temperature is automatically set 2°C higher.
Also the horizontal vane swings in various cycles.
SWING operation makes you feel cooler than set temperature. So, even though the set temperature is higher, the
air conditioner can keep comfort. As a result, energy can be saved.
To cancel this operation, select a different mode or press one of the following buttons in ECONO COOL operation:
ECONO COOL, VANE CONTROL or POWERFUL button.
(9) POWERFUL ( ) operation
The air conditioner automatically adjusts the fan speed and the set temperature, and operates the POWERFUL mode.
The POWERFUL mode is cancelled automatically 15 minutes after operation starts. To cancel this operation manual-
ly, select a different mode or press one of the following buttons: POWERFUL, OPERATE/STOP (ON/OFF), ECONO
COOL, or FAN, SPEED CONTROL button.
(5) STOP (operation OFF) and ON TIMER standby
In the following cases, the horizontal vane returns to the closed position.
(a) When OPERATE/STOP (ON/OFF) button is pressed (POWER OFF).
(b) When the operation is stopped by the emergency operation.
(c) When ON TIMER is ON standby.
(6) Dew prevention
During COOL or DRY operation with the vane angle at Angle 4 or 5 when the compressor cumulative operation time
exceeds 1 hour, the vane angle automatically changes to Angle 1 for dew prevention.
(10) LONG MODE (
)
(MS-GF50/60/80VA)
By pressing LONG button indoor fan speed becomes faster than setting fan speed on the remote controller, and the
horizontal vane moves to the position for LONG mode. The remote controller displays “
”. To cancel this opera-
tion, press one of the following buttons: LONG, VANE CONTROL, or ECONO COOL (during cool mode). In the fol-
lowing example, the vertical vane is set to
(front.).
2. Vertical vane (MS-GF50/60/80VA)
(1) Vane motor drive
These models are equipped with a stepping motor for the vertical vane. The rotating direction, speed, and angle of
the motor are controlled by pulse signals (approximate 12 V) transmitted from microprocessor.
(2) The vertical vane angle and mode change as follows by pressing WIDE VANE CONTROL button.
(3) Positioning
To confirm the standard position, the vane moves until it touches the vane stopper. Then the vane is set to the select-
ed angle.
(SWING)
1
2
3
4
5
6
Confirming of standard position is performed in the following cases:
(a) OPERATE/STOP (ON/OFF) button is pressed (POWER ON).
(b) SWING is started.
(4) SWING (
) MODE
By selecting SWING mode with WIDE VANE button, the vertical vane swings horizontally. The remote controller displays
“
”. Swing mode is cancelled when WIDE VANE button is pressed once again.
(5) WIDE MODE (
)
By selecting WIDE mode with WIDE VANE button, indoor fan speed becomes faster than setting fan speed on the
remote controller ( ). The remote controller displays “
”.
Indoor fan speed becomes faster than setting fan speed on the remote controller even when
or
is selected.
OBH621A