PROGRAM TIMER
• OFF timer and ON timer can be used in combination.
• " " and " " display shows the order of OFF timer and ON timer operation.
(Example 1) The current time is 8:00 PM.
The unit turns OFF at 11:00 PM, and ON at 6:00 AM.
(Example 2) The current time is 11:00 AM.
The unit turns ON at 5:00 PM, and OFF at 9:00 PM.
NOTE: TIMER setting will be cancelled by failure or breaker functioning.
9-7. EMERGENCY/TEST OPERATION
In case of test run operation or emergency operation, use EMERGENCY OPERATION switch on the front of the indoor
unit. Emergency operation is available when the remote controller is missing, has failed or batteries of remote controller
run down. The unit will start and OPERATION INDICATOR lamp will light.
The first 30 minutes of operation is the test run operation. This operation is for servicing. The indoor fan speed runs at
High speed and the temperature control does not work.
After 30 minutes of test run operation, the system shifts to EMERGENCY COOL MODE with a set temperature of 24
˚
C.
The fan speed shifts to Med. speed.
The coil frost prevention works even in the test run or the emergency operation.
In the test run or emergency operation, the horizontal vane operates in VANE AUTO ( ) mode.
Emergency operation continues until EMERGENCY OPERATION switch is pressed again or the unit receives any signal
from the remote controller. In case of latter, normal operation will start.
NOTE:
Do not press EMERGENCY OPERATION switch during normal operation.
• The following indication applies regardless of shape of the indicator.
9-8. 3-MINUTE TIME DELAY OPERATION
When the system turns OFF, compressor will not restart for 3 minutes as 3-minute time delay function operates to protect
compressor form overload.
OBH511A