10
(4) The initial set temperature is decided by the initial room temperature.
Model
Initial room temperature
Initial set temperature
COOL mode of
" I FEEL CONTROL"
26
˚
C or more
24
˚
C
1
25
˚
C to 26
˚
C
Initial room temperature minus 2
˚
C
DRY mode of
" I FEEL CONTROL"
more than 13
˚
C, less than 25
˚
C
Initial room temperature minus 2
˚
C
1 When the system is restarted with the remote controller, the system operates with the previous set temperature
regardless of room temperature at restart.
The set temperature is calculated by the previous set temperature.
(5) TEMPERATURE buttons
In " I FEEL CONTROL " ( ) mode, set temperature is decided by the microprocessor based on the room temperature.
In addition, set temperature can be controlled by TOO WARM or TOO COOL buttons when you feel too cool or too
warm.
Each time the TOO WARM or TOO COOL button is pressed, the indoor unit receives the signal and emits a beep tone.
• Fuzzy control
When the TOO COOL or TOO WARM button is pressed, the microprocessor changes the set temperature, consider-
ing the room temperature, the frequency of pressing TOO COOL or TOO WARM button and the user's preference to
heat or cool. So this is called "Fuzzy control", and works only in "I FEEL CONTROL" mode.
In DRY mode of "I FEEL CONTROL", the set temperature doesn't change.
…To raise the set temperature 1~2
˚
C
…To lower the set temperature 1~2
˚
C
9-5. AUTO VANE OPERATION
1. Horizontal vane
(1) Vane motor drive
These models are equipped with a stepping motor for the horizontal vane. The rotating direction, speed, and angle of
the motor are controlled by pulse signals (approximate 12 V) transmitted from indoor microprocessor.
(2) The horizontal vane angle and mode change as follows by pressing the VANE button.
OBH511A