6
INDOOR UNIT
Room
temperature
thermistor
Indoor
heat
exchanger
RT11
Indoor coil
thermistor
RT12
Refrigerant pipe
(Option)
{
6.35
(with heat insulator)
Flared
connection
Flared
connection
Refrigerant pipe
(Option)
{
12.7
(with heat insulator)
Refrigerant flow in cooling
REFRIGERANT SYSTEM DIAGRAM
6
MS-A08VD -
MS-A10VD -
P1
P1
INDOOR UNIT
Room
temperature
thermistor
Indoor
heat
exchanger
RT11
Indoor coil
thermistor
RT12
Refrigerant pipe
(Option)
{
6.35
(with heat insulator)
Flared
connection
Flared
connection
Refrigerant pipe
(Option)
{
9.52
(with heat insulator)
MS-A13VD -
P1
Unit : mm
WIRING DIAGRAM
5
MS-A08VD -
MS-A10VD -
MS-A13VD -
P1
P1
P1
INDOOR UNIT
GRN
BLU
BRN
GRN/YLW
GRN/YLW
POWER
SUPPLY
CORD
220-230-240V
~
/N 50Hz
LD103
F12
BLU
BLU
2
1
BLU
220-230-240V
~
5
MV
151
CN
TO OUTDOOR
UNIT
CONNECTING
BRN
L
N
TB
2
BLU
WHT
POWER MONITOR,
RECEIVER
P.C.BOARD
REMOTE
CONTROLLER
2
109
CN
2
SAFETY
DEVICE(FAN)
1R1
CN
CN
125
CN201
3
2
1
ELECTRONIC CONTROL P.C. BOARD
3
T11
RED
WHT
NR11
SR141
F11
C11
111
CN
CN
112
3
121
CN
CN211
6
5
BRN
YLW
GRY
BLK
4
3
2
1
MF
RT11
RT12
1
3
5
52C
3
4
SYMBOL
SR141
TB
T11
52C
SYMBOL
MV
NR11
RT11
RT12
SYMBOL
C11
F11
F12
MF
NAME
NAME
NAME
INDOOR FAN CAPACITOR
FUSE(3.15A)
THERMAL FUSE(93
:
)
INDOOR FAN MOTOR(INNER FUSE)
VANE MOTOR
VARISTOR
ROOM TEMPERATURE THERMISTOR
INDOOR COIL THERMISTOR
SOLID STATE RELAY
TERMINAL BLOCK
TRANSFORMER
CONTACTOR
MODELS WIRING DIAGRAM
NOTE:1. About the outdoor side electric wiring refer to the outdoor unit electric wiring diagram for servicing.
2. Use copper conductors only. (For field wiring)
3. Symbols below indicate.
/
: Terminal block, : Connector
OB396--1.qxp 05.3.18 8:59 AM Page 6