47
OPERATING PROCEDURE
PHOTOS
1. Removing the front panel
(1) Remove the screws caps at the down of the front panel.
Remove the screws.
(2) Pull the panel down to your side slightly and unhook the
catches at the top.
2. Removing the electronic control P.C. board
(1) Remove the front panel. (Refer to 1)
(2) Remove the electriccal cover.
(3) Remove the screw, remove the terminal cover.
(4) Remove the screw on the terminal block.
(5) Unhook the catch of the lamp holder.
(6) Remove the receiver holder.
(7) Disconnect the connectors and the lead wire from 52C
relay on the electronic control P.C. board and remove the
ground and the indoor coil thermistor.
(8) Remove the electronic control P.C. board.
11-2 MS-18NV -
MS-24NV -
MS-18NV -
MS-24NV -
MS-18NV -
INDOOR UNIT
E3
E2
E2
E1
E1
Photo 2
Photo 1
Front panel
Screws
Screw
Terminal
block
screw
Indoor coil thermistor
Indoor
electronic
control
P.C. board
Ground
OB206t-2.qxp 25/9/97 8:40 PM Page 47
Содержание MS-07NV - E2 (WH)
Страница 4: ...4 REMOTE CONTROLLER MS 07NV MS 09NV MS 12NV MS 18NV MS 24NV MS 18NV E2 E1 E1 E1 E1 E1 ...