Active filter module
PUZ-HA30NHA4 PUZ-HA36NHA4
L1, L
Connect to the
DCL(Reactor)
Connect to the
outdoor power
circuit board
(TABP1)
Connect to the outdoor power
circuit board(TABN1)
+
–
Io
Connect to the outdoor power
circuit board(TABN)
N
Non-connect
N1
Non-connect
P
Connect to the outdoor power
circuit board(TABP)
Connect to the outdoor power
circuit board(CNAF)
1
: GND
-1 : 18V DC
-1 : Control signal
, : Not used
6-1 : Control signal
Upper side
Lower side
+
DCL
L1
L2
ACTM
P
Io
N1
N2
(+)
(- )
Load
Connection and internal circuit diagram
Error condition Normal value (reference)
Symptom when the unit is in trouble
(–) and Io
open
less than 1
"
1
The unit does not operate (can not be switched ON)
(–) and L
short
100k
"
~ 1M
"
1
The breaker operates
open
W
1
1
The unit does not operate (can not be switched ON)
2
U9 Abnormal stop (
W
)
P and L
short
100k
"
~ 1M
"
1
The breaker operates
open
W
1
1
The unit does not operate (can not be switched ON)
2
U9 Abnormal stop (
W
)
P and Io
short
100k
"
~ 1M
"
1
The breaker operates
open
W
1
1
The unit does not operate (can not be switched ON)
2
U9 Abnormal stop (
W
)
L and Io
short
100k
"
~ 1M
"
1
The breaker operates
open
W
1
1
The unit does not operate (can not be switched ON)
2
U9 Abnormal stop (
W
)
Tester check points of Acive filter module
W
1.The symptom when the unit is in open error condition is described to determine open error by tester check.
W
.SW setting : Code "0" display
1
6
ON
OFF