14
en
7.1. Restriction
7.1.1 Setting the temperature range restriction
<Button operation>
Select “Energy saving” from
the Main menu, and press the
[SELECT] button.
Move the cursor to “Restriction”
with the [F1] or [F2] button, and
press the [SELECT] button.
The screen to set the temperature
range will appear.
Move the cursor to the desired
item with the [F1] button out of
“Temp. range,” “Cool•Dry,” “Heat,”
or “Auto.”
The current settings will appear.
Move the cursor to “Temp. range”
with the [F1] or [F2] button, and
press the [SELECT] button.
7. Energy Saving
Main
Main menu
Energy saving
F1
F2
F3
F4
Main menu:
Cursor
Energy saving
Restriction
Energy saving
Energy data
F1
F2
F3
F4
Setting display:
Page
Restriction
Temp. range
No
Cool•Dry 25°C - 28°C
Heat
20°C - 25°C
Auto
22°C - 28°C
F1
F2
F3
F4
Select:
Temp. range
Cursor
Cur.
Temp. range
No /
Yes
Cool•Dry 25°C - 28°C
Heat 20°C - 25°C
Auto 22°C - 28°C
F1
F2
F3
F4
Change the settings with the [F3] or
[F4] button.
• Temp. range: No (unrestricted) or
Yes (restricted)
• Cool•Dry: Upper and lower limit
temperature (1ºC increments)
• Heat: Upper and lower limit tem-
perature (1ºC increments)
• Auto: Upper and lower limit tem-
perature (1ºC increments)
Temperature setting ranges
Mode
Lower limit
Upper limit
Cool•Dry *1
*3
19 ~ 30ºC
(67 ~ 87ºF)
30 ~ 19ºC
(87 ~ 67ºF)
Heat
*2
*3
17 ~ 28ºC
(63 ~ 83ºF)
28 ~ 17ºC
(83 ~ 63ºF)
Auto
*
4
19 ~ 28ºC
(67 ~ 83ºF)
28 ~ 19ºC
(83 ~ 67ºF)
* The settable range varies depending on the connected unit.
*1 Temperature ranges for the Cool, Dry, and Auto (dual set point) modes
can be set.
*2 Temperature ranges for the Heat and Auto (dual set point) modes can
be set.
*3 Temperature ranges for the Heat, Cool, and Dry modes must meet the
conditions below:
• Upper limit for cooling - upper limit for heating ≥ Minimum temperature
difference (varies with indoor unit model)
• Lower limit for cooling - lower limit for heating ≥ Minimum temperature
difference (varies with indoor unit model)
*4 Temperature range for the Auto (single set point) mode can be set.
Press the [SELECT] button to save the settings.
A confirmation screen will appear.
Navigating through the screens
• To go back to the Main menu ........... [MENU] button
• To return to the previous screen ....... [RETURN] button
will appear on the Status
display and the Main display in the
Full mode when the temperature
range is restricted.
Select:
Temp. range
Temp. range
No /
Yes
Cool•Dry
25
°C - 28°C
Heat 20°C - 25°C
Auto 22°C - 28°C
Cursor
Temp.
F1
F2
F3
F4
Cool
Room
Auto
Set temp.
Mode
Temp.
Fan
Fri
28.5
Main menu:
Changes saved
Temp. range
Temp. range
No /
Yes
Cool•Dry
25°C - 28°C
Heat 20°C - 25°C
Auto 22°C - 28°C
7.1.2 Operation locked function
<Button operation>
To enable the operation lock function, set the item “Operation locked” to
“Yes”.
Bring up the Restriction setting
screen. (Refer to 7.1.1)
Move the cursor to “Operation
locked” and press the [SELECT]
button.
F1
F2
F3
F4
Setting display:
Page
Restriction 2/2
Operation locked No
On/Off Mode Set temp.
Vane Menu Fan
Louver
RG79F446H02_01en.indd 14
2021/03/24 9:09:04
016