20
NOTE:
1. Rating conditions (ISO T1)
Cooling : Indoor: D.B. 27
:
(80˚F) W.B. 19
:
(66˚F)
Outdoor : D.B. 35
:
(95˚F) W.B. 24
:
(75˚F)
Refrigerant piping length (one way) : 5m (16ft.)
2. Guaranteed operating range
Indoor
Outdoor
Cooling
Upper limit D.B. 35˚C, W.B. 22.5˚C
D.B. 46˚C
Lower limit D.B. 19˚C, W.B. 15˚C
D.B. -5˚C
4. Above data based on indicated voltage
Indoor unit
Single phase 230V 50Hz
Outdoor unit
Single phase 230V 50Hz, 3 phase 400V 50Hz
3. Guaranteed voltage
198~264V, 50Hz
5. Refer to the service manual of outdoor unit for tha outdoor
unit's specifications.
Weight
kg (lbs.)
Service Ref.
Item
Function
Capacity
Btu/h
W
Total input
kW
Service Ref.
Power supply (phase, cycle, voltage)
Input
kW
Running current
A
Starting current
A
External finish (Panel)
Heat exchanger
Fan
Fan (drive)
o
No.
Fan motor output
kW
Airflow
(Low-Medium2-Medium1-High)
K
/ min (CFM)
External static pressure
Pa (mmAq)
Booster heater
kW
Operation control & Thermostat
Sound level
(Low-Medium2-Medium1-High)
dB
Unit drain pipe I.D.
mm (in.)
Dimensions
Indoor unit
W
mm (in.)
D
mm (in.)
H
mm (in.)
PLA-RP5AA
1
.UK
PLA-RP6AA.UK
PLA-RP6AA
1
.UK
Cooling
45,400
48,500
13,300
14,200
5.09
5.90
PLA-RP5AA
1
.UK
PLA-RP6AA
1
.UK
PLA-RP6AA.UK
Single phase, 50Hz, 220-230-240V
0.33
0.33
1.64
1.64
2.0
2.0
Munsell 0.70Y 8.59/0.97
Plate fin coil
Turbo fan (direct)
o
1
0.120
22-25-28-30 (775-880-990-1,060)
0 (direct blow)
—
Remote controller & built-in
37-40-43-45
32 (1-1/4)
PU-P5YGAA.UK
PU-P5YGAA
1
.UK
PU-P6YGAA.UK
PU-P6YGAA
1
.UK
Outdoor unit Service Ref.
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 298 (11-3/4),
PANEL : 30 (1-3/16)
UNIT : 32 (71),
PANEL : 5 (11)
Weight
kg (lbs.)
Service Ref.
Item
Function
Capacity
Btu/h
W
Total input
kW
Service Ref.
Power supply (phase, cycle, voltage)
Input
kW
Running current
A
Starting current
A
External finish (Panel)
Heat exchanger
Fan
Fan (drive)
o
No.
Fan motor output
kW
Airflow
(Low-Medium2-Medium1-High)
K
/ min (CFM)
External static pressure
Pa (mmAq)
Booster heater
kW
Operation control & Thermostat
Sound level
(Low-Medium2-Medium1-High)
dB
Unit drain pipe I.D.
mm (in.)
Dimensions
Indoor unit
W
mm (in.)
D
mm (in.)
H
mm (in.)
Cooling
26,300
32,800
7,700
9,600
3.42
3.68
PLA-RP3AA
1
.UK
PLA-RP4AA
1
.UK
PLA-RP3AA.UK
PLA-RP4AA.UK
Single phase, 50Hz, 220-230-240V
0.16
0.25
0.79
1.25
1.0
2.0
Munsell 0.70Y 8.59/0.97
Plate fin coil
Turbo fan (direct)
o
1
0.070
0.120
15-16-18-20 (530-565-635-705)
20-23-26-28 (705-810-920-990)
0 (direct blow)
—
Remote controller & built-in
28-30-32-34
33-36-39-41
32 (1-1/4)
PU-P3VGAA.UK / PU-P3YGAA.UK
PU-P3VGAA
1
.UK / PU-P3YGAA
1
.UK
PU-P4VGAA.UK / PU-P4YGAA.UK
PU-P4VGAA
1
.UK / PU-P4YGAA
1
.UK
PLA-RP3AA
1
.UK
PLA-RP3AA.UK
PLA-RP4AA
1
.UK
PLA-RP4AA.UK
Outdoor unit Service Ref.
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 258 (10-3/16), PANEL : 30 (1-3/16)
UNIT : 24 (53),
PANEL : 5 (11)
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 298 (11-3/4),
PANEL : 30 (1-3/16)
UNIT : 30 (66),
PANEL : 5 (11)
OC297-E-1.qxp 05.5.6 5:29 PM Page 20