48
1 2
Normal operation
ON
OFF
1 2
For emergency cooling
ON
OFF
1 2
For emergency heating
ON
OFF
1 2 3 4
ON
OFF
SW5-1) Power supply
SW5-2) OFF:For models with heat pump
ON :For models without heat pump
SW5-3) Not for use
SW5-4) This switch is unavailable Keep this switch at OFF.
(5) SW6 (Model selector)
1 2 3 4
ON
OFF
Single control
Twin control
Triple control
SW6-1
OFF
ON(Twin NO.1) ON(Triple NO.1)
SW6-2
OFF
ON(Twin NO.2) ON(Triple NO.2)
SW6-3
OFF
OFF
ON(Triple NO.3)
SW6-4
OFF
OFF
ON
(6) SW7 (Model selector)
Switch to set the output of phase-controlled indoor fan motor.
Address setting is available at any time/
The initial factory setting by is based on each capacity.
Service Ref.
SW7
PKH-2FKA
3
1 2 3
ON
OFF
3. On indoor controller board
For PKH-2.5FKA
2
, PKH-2.5FKA
3
, PKH-3FKA
2
, PKH-3FKA
3
, PKH-4FKSA
2
, PKH-4FKSA
3
(1) J1 (Mode selector)
4
5
6
7
8
9
10
ON :230V/240V
OFF:220V
)
(
(2) SW2 (Address selector)
(3) SW3 (Emergency operation switch)
(4) SW5 (Model selector)
Used in setting the unit-address for group control.
For further information, refer to page 55.
1 2 3 4 5 6
ON
OFF