Mitsubishi Electric Mr. Slim PKA-RP100KAL Скачать руководство пользователя страница 7

7

3. Operation

3.4. Fan speed setting

F1

F2

F3

F4

Cool

Room

Auto

Set temp.

Mode

Temp.

Fan

Fri

Press the [F4] button to go through the fan speeds in the following order.

Auto

•  

The available fan speeds depend on the models of connected indoor 
units.

Note:

 

The number of available fan speeds depends on the type of unit 
connected. Note also that some units do not provide an “Auto” setting.

 

In the following cases, the actual fan speed generated by the unit will differ 
from the speed shown the remote controller display.
1.  While the display is showing “STAND BY” or “DEFROST”.
2.  When the temperature of the heat exchanger is low in the heat mode. 

(e.g. immediately after heat operation starts)

3.  In HEAT mode, when room temperature is higher than the temperature 

setting.

4.  When the unit is in DRY mode.

■  Automatic fan speed setting (For wireless remote controller)
  It is necessary to set for wireless remote controller only when automatic 

fan speed is not set at default setting.
It is not necessary  to set for wired remote controller with automatic fan 
speed at default setting.

 Press the SET button with something sharp at the end.

Operate when display of remote controller is off.

MODEL SELECT

  

blinks and Model No. is lighted

 

.

 Press the AUTO STOP 

 button.

 

blinks and setting No. is lighted

 

.

(Setting No.01: without automatic fan speed)

 Press the temp.

 

 

buttons to set the setting No.02.

    

(Setting No.02:with automatic fan speed)

If you mistook the operation, press the ON/OFF 

 button and operate 

again from procedure 

.

 Press the SET button with something sharp at the end.

MODEL SELECT

 

and Model No. are lighted for 3 seconds, then turned off.

ON/OFF

  TEMP

RESET

SET

CLOCK

MODEL SELECT

FAN

VANE

TEST RUN

AUTO STOP

AUTO START

h

min

LOUVER

MODE

CHECK

3.5. Airflow direction setting

3.5.1 Navigating through the Main menu

<Accessing the Main menu>

Press the [MENU] button.
The Main menu will appear.

F1

F2

F3

F4

Main

Main display:

Cursor

Page

Main menu

Vane

·

Louver

·

Vent. (Lossnay)

High power
Timer
Weekly timer
OU silent mode

<Item selection>

F1

F2

F3

F4

Main

Main display:

Cursor

Page

Main menu

Vane

·

Louver

·

Vent. (Lossnay)

High power
Timer
Weekly timer
OU silent mode

Cursor

Press [F1] to move the cursor down.
Press [F2] to move the cursor up.

<Navigating through the pages>

Press [F3] to go to the previous 
page.
Press [F4] to go to the next page.

F1

F2

F3

F4

Main

Main display:

Cursor

Page

Main menu

Vane

·

Louver

·

Vent. (Lossnay)

High power
Timer
Weekly timer
OU silent mode

page

<Saving the settings>

F1

F2

F3

F4

OU silent mode

Mon

 Tue Wed Thu Fri Sat Sun 

 Start         Stop     Silent
             -

Setting display:

day

Select the desired item, and press 
the [SELECT] button.

The screen to set the selected item 
will appear.

<Exiting the Main menu screen>

Press the [RETURN] button to exit 
the Main menu and return to the 
Main display. 

F1

F2

F3

F4

Cool

Room

Auto

Set temp.

Mode

Temp.

Fan

Fri

If no buttons are touched for 
10 minutes, the screen will 
automatically return to the Main 
display. Any settings that have not 
been saved will be lost.

Содержание Mr. Slim PKA-RP100KAL

Страница 1: ...aire acondicionado para garantizar un uso seguro y correcto MANUAL DE OPERAÇÃO Para segurança e utilização correctas leia atentamente o manual de operação antes de pôr a funcionar a unidade de ar condicionado DRIFTSMANUAL Læs venligst denne driftsmanual grundigt før airconditionanlægget betjenes af hensyn til sikker og korrekt brug EΓXEIPIΔIO OΔHΓIΩN XPHΣEΩΣ Για ασφάλεια και σωστή χρήση παρακαλείσ...

Страница 2: ...t Fire may result Do not place a gas heater or any other open flame appliance where it will be exposed to the air discharged from the unit Incomplete combustion may result Do not remove the front panel or the fan guard from the outdoor unit when it is running This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial use by lay person...

Страница 3: ...in menu Backlit LCD Operation settings will appear When the backlight is off pressing any button turns the backlight on and it will stay lit for a certain period of time depending on the screen When the backlight is off pressing any button turns the backlight on and does not perform its function except for the ON OFF button ON OFF lamp This lamp lights up in green while the unit is in operation It...

Страница 4: ...ppears here Appears when the buttons are locked Full mode All icons are displayed for explanation Fri Mode Temp Fan Room Cool Auto Set temp Basic mode Fri Cool Mode Temp Fan Auto Set temp Appears when the On Off timer Night setback or Auto off timer function is enabled appears when the timer is disabled by the centralized control system Appears when the Weekly timer is enabled Appears while the un...

Страница 5: ...e controller carefully Do not drop the remote controller or subject it to strong shocks In addition do not get the remote controller wet or leave it in a location with high humidity To avoid misplacing the remote controller install the holder included with the remote controller on a wall and be sure to always place the remote controller in the holder after use For explanation purposes all of the i...

Страница 6: ...ected to the same outdoor unit are already operated in a different mode In this case the rest of the unit in the same group can only be operated in the same mode Automatic operation According to a set temperature cooling operation starts if the room temperature is too hot and heating operation starts if the room temperature is too cold During automatic operation if the room temperature changes and...

Страница 7: ...02 with automatic fan speed If you mistook the operation press the ON OFF button and operate again from procedure Press the SET button with something sharp at the end MODELSELECT and Model No are lighted for 3 seconds then turned off ON OFF TEMP RESET SET CLOCK MODELSELECT FAN VANE TEST RUN AUTO STOP AUTO START h min LOUVER MODE CHECK 3 5 Airflow direction setting 3 5 1 Navigating through the Main...

Страница 8: ... No indication on the remote controller Display of unsupported functions The message at left will appear if the user selects a function not sup ported by the corresponding indoor unit model F1 F2 F3 F4 Title Not available Unsupported function Return 3 5 2 Vane Vent Lossnay Accessing the menu F1 F2 F3 F4 Main Main display Cursor Page Main menu Vane Louver Vent Lossnay High power Timer Weekly timer ...

Страница 9: ...g off Lighting Operation details at the time of emergency operation are as shown below Operation Mode COOL HEAT Set Temperature 24 C 24 C Fan Speed High High Airflow Direction Up and Down Setting 1 Setting 4 5 Cooling Heating Stop Cooling Stop When the remote controller cannot be used When the batteries of the remote controller run out or the remote controller malfunctions the emergency operation ...

Страница 10: ...nstalled in a space with ordinary air quality Depending on the air quality the filter may require more frequent cleaning The cumulative time at which filter needs cleaning depends on the model This indication is not available for wireless remote controller Cleaning the filters Clean the filters using a vacuum cleaner If you do not have a vacuum cleaner tap the filters against a solid object to kno...

Страница 11: ...it If the indoor temperature and the humidity are high this condition may occur when operation starts During defrosting mode cool airflow may blow down and appear like a mist Water or vapor is emitted from the outdoor unit During cool mode water may form and drip from the cool pipes and joints During heat mode water may form and drip from the heat exchanger During defrosting mode water on the heat...

Страница 12: ...e batteries and press the Reset button If nothing appears even after the batteries are replaced make sure that the batteries are installed in the correct directions The operation lamp near the receiver for the wireless remote controller on the indoor unit is flashing The self diagnosis function has operated to protect the air conditioner Do not attempt to repair this equipment by yourself Turn off...

Страница 13: ...ионированный доступ посторонних лиц к приборам этого класса Данны прибор не должен устанавливаться пользователем Обратитесь к поставщику или в специализированное предприятие и закажите установку прибора При неправильной установке может произойти утечка воды электрический шок или пожар Никогда не занимайтесь ремонтом или переносом прибора не кто иной место самостоятельно Не ставьте какие либо посто...

Страница 14: ...ючена нажатие любой кнопки включает подсветку но не приводит к выполнению ее функции кроме кнопки ВКЛ ВЫКЛ Индикатор ВКЛ ВЫКЛ Индикатор будет гореть зеленым цветом когда устройство находится в работе Индикатор будет мигать при включении контроллера или при возникновении ошибки Функциональная кнопка F1 Главное окно нажмите для изменения режима работы Главное меню нажмите чтобы переместить курсор вн...

Страница 15: ... по установке Здесь отображается текущая комнатная температура Отображается когда кнопки заблокированы Полный режим отображения Все значки показаны для иллюстрации и описания Базовый режим отображения Отображается когда включена функция Таймер ВКЛ ВЫКЛ Ночной режим или Автоотключение таймера появляется когда таймер отключен централизованной системой управления Отображается когда включен таймер на ...

Страница 16: ...станционного управления и не подвергайте его сильным ударам Кроме того следите за тем чтобы пульт дистанционного управления не попал в воду и не оставляйте его в местах с высокой влажностью Во избежание неправильного местоположения пульта дистанционного управления установите на стене держатель входящий в комплект поставки пульта дистанционного управления и обязательно устанавливайте пульт дистанци...

Страница 17: ...Нагрев и Auto Авт Cool Room28 5 Auto Set temp Mode Temp Fan Fri 28 5 Пример дисплея по Цельсию с шагом 0 5 градуса F1 F2 F3 F4 Cool Room Auto Set temp Mode Temp Fan Fri Нажмите кнопку F2 чтобы уменьшить заданную температуру а что бы увеличить нажмите кнопку F3 Задаваемые диапазоны температур для различных режимов рабо ты см в таблице на стр 128 Заданный температурных диапазон не может быть установ...

Страница 18: ...ивается как Настройка 01 без автоматической настройки скорости вентилятора Нажмите кнопки установки температуры чтобы выбрать настройку 02 Настройка 02 с автоматической настройкой скорости вентилятора При неправильном выборе операции нажмите кнопку ON OFF ВКЛ ВЫКЛ и вновь начните выполнение операции с пункта Нажмите кнопку SET остроконечным предметом MODELSELECT и номер модели высвечиваются в тече...

Страница 19: ...тройка возможно только когда подключен блок Lossnay Off Low High Off Low High Вентилятор на некоторых моде лях внутренних блоков может блокироваться при использо вании с некоторыми моделями блоков вентиляции Возврат в главное меню F1 F2 F3 F4 Main Main display Cursor Page Main menu Vane Louver Vent Lossnay High power Timer Weekly timer OU silent mode Примечание В режиме качания индикация направлен...

Страница 20: ...пульта дистанционного управления разрядились или в немимеется неисправность аварийный режим можно включить с помощьюаварийных кнопок на решетке Лампа DEFROST STAND BY РАЗМОРАЖИВАНИЕ ОЖИДАНИЕ Оранжевый Лампа работы Зеленый Переключатель аварийной работы обогрев охлаждение Приемник Каждое нажатие кнопки аварийного останова приводит к переключению рабочего режима Проверьте COOL HEAT на мониторе опера...

Страница 21: ...ользованием пылесоса При отсутствии пылесоса легким постукиванием фильтра о твердый предмет стряхните с него грязь или пыль Если фильтры сильно загрязнены промойте их в теплой воде Тщательно смойте остатки моющего средства и полностью просушите фильтры перед их обратной установкой в прибор Осторожно Не сушите фильтры под прямыми солнечными лучами или с использованием источника отопления такого как...

Страница 22: ... В режиме размораживания может подаваться холодный воздушный поток который может казаться дымкой Из наружного прибора выходит вода или пар В режиме охлаждения вода может образовываться и капать с холодных труб и стыков В режиме обогрева вода может образовываться и капать с теплообменника В режиме размораживания вода на теплообменнике испаряется и может появиться водяной пар На дисплее пульта диста...

Страница 23: ... помещении Помещения с высоким уровнем поглощения шума Обычные помещения Помещения с низким уровнем поглощения шума Примеры местоположения Студия радиовещания музыкальная студия и т д Приемная вестибюль гостиницы и т д Офис гостиничный номер Уровни шума от 3 до 7 дБ от 6 до 10 дБ от 9 до 13 дБ На пульте дистанционного управления ничего не отображается дисплей тусклый или внутренний прибор получает...

Страница 24: ... EG representant som är auktoriserad att sammanställa den tekniska filen är följande Avrupa Birliği nde bulunan ve teknik dosyayı düzenleme yetkisine sahip yetkili temsilcimiz aşağıda belirtilmiştir Наш авторизованный представитель в ЕС уполномоченный на составление технического файла указан ниже MITSUBISHI ELECTRIC EUROPE B V HARMAN HOUSE 1 GEORGE STREET UXBRIDGE MIDDLESEX UB8 1QQ U K Yoji SAITO P...

Страница 25: ...eden causar asfixia Se debe proporcionar la ventilación determinada en EN378 1 Asegúrese de colocar el aislante alrededor de las tuberías El contacto directo con la tube ría puede ocasionar quemaduras o congelación Para evitar una ingestión accidental no coloque las pilas en su boca bajo ningún concepto La ingestión de las pilas puede causar asfixia y o envenenamiento Coloque la unidad en una estruc...

Страница 26: ...e be sure to put the contact address telephone number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Printed in Thailand RG79Y672H01 ...

Отзывы: