Mitsubishi Electric Mr. Slim PKA-RP100KAL Скачать руководство пользователя страница 6

6

3. Operation

 About the operation method, refer to the operation manual that comes with each remote controller.

3.1. Turning ON/OFF
[ON] [OFF]

Press the [ON/OFF] button.
The ON/OFF lamp will light up in 
green, and the operation will start.

Press the [ON/OFF] button again. 
The ON/OFF lamp will come off, 
and the operation will stop.

 Operation status memory

Remote controller setting

Operation mode

Operation mode before the power was turned off

Preset temperature

Preset temperature before the power was turned off

Fan speed

Fan speed before the power was turned off

 Settable preset temperature range

Operation mode

Preset temperature range

Cool/Dry

19 ~ 30 ºC

Heat

17 ~ 28 ºC

Auto

19 ~ 28 ºC

Fan/Ventilation

Not settable 

Note:
Even if you press the ON/OFF button immediately after shutting down the operation is progress, the air conditioner will not start for about 3 minutes.
This is to prevent the internal components from being damaged.

3.2. Mode Selection

Press the [F1] button to go through the op-
eration modes in the order of “Cool”, “Dry”, 
“Fan”, “Auto”, and “Heat”. Select the desired 
operation mode.

Cool

Dry

Fan

Auto

Heat

 • Operation modes that are not available 

to the connected outdoor unit models will 
not appear on the display.

What the blinking mode icon means

The mode icon will blink when other indoor units in the same refrigerant 
system (connected to the same outdoor unit) are already operated in a 
different mode. In this case, the rest of the unit in the same group can 
only be operated in the same mode.

Automatic operation 

 According to a set temperature, cooling operation starts if the room 

temperature is too hot and heating operation starts if the room 
temperature is too cold.

 During automatic operation, if the room temperature changes and 

remains 2.0 °C or more above the set temperature for 15 minutes, the 
air conditioner switches to cool mode. In the same way, if the room 
temperature remains 2.0 °C or more below the set temperature for 
15 minutes, the air conditioner switches to heat mode.

Cool mode

15 minutes (switches 
from heating to cooling)

Set tempe2.0°C

Set temperature

Set temperature -2.0°C

15 minutes (switches 
from cooling to heating)

3.3. Temperature setting

<Cool, Dry, Heat, and Auto>

Cool

Room

28.5

Auto

Set temp.

Mode

Temp.

Fan

Fri

28.5

Example display

(Centigrade in 0.5-degree increments)

F1

F2

F3

F4

Cool

Room

Auto

Set temp.

Mode

Temp.

Fan

Fri

Press the [F2] button to decrease the preset temperature, and press the  
[F3] button to increase.
•  

Refer to the table on page 6 for the settable temperature range for dif-
ferent operation modes.

•  

Preset temperature range cannot be set for Fan/Ventilation operation.

•  

Preset temperature will be displayed either in Centigrade in 0.5- or 
1-degree increments, or in Fahrenheit, depending on the indoor unit 
model and the display mode setting on the remote controller.

F1

F2

F3

F4

Cool

Room

Auto

Set temp.

Mode

Temp.

Fan

Fri

Содержание Mr. Slim PKA-RP100KAL

Страница 1: ...aire acondicionado para garantizar un uso seguro y correcto MANUAL DE OPERAÇÃO Para segurança e utilização correctas leia atentamente o manual de operação antes de pôr a funcionar a unidade de ar condicionado DRIFTSMANUAL Læs venligst denne driftsmanual grundigt før airconditionanlægget betjenes af hensyn til sikker og korrekt brug EΓXEIPIΔIO OΔHΓIΩN XPHΣEΩΣ Για ασφάλεια και σωστή χρήση παρακαλείσ...

Страница 2: ...t Fire may result Do not place a gas heater or any other open flame appliance where it will be exposed to the air discharged from the unit Incomplete combustion may result Do not remove the front panel or the fan guard from the outdoor unit when it is running This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial use by lay person...

Страница 3: ...in menu Backlit LCD Operation settings will appear When the backlight is off pressing any button turns the backlight on and it will stay lit for a certain period of time depending on the screen When the backlight is off pressing any button turns the backlight on and does not perform its function except for the ON OFF button ON OFF lamp This lamp lights up in green while the unit is in operation It...

Страница 4: ...ppears here Appears when the buttons are locked Full mode All icons are displayed for explanation Fri Mode Temp Fan Room Cool Auto Set temp Basic mode Fri Cool Mode Temp Fan Auto Set temp Appears when the On Off timer Night setback or Auto off timer function is enabled appears when the timer is disabled by the centralized control system Appears when the Weekly timer is enabled Appears while the un...

Страница 5: ...e controller carefully Do not drop the remote controller or subject it to strong shocks In addition do not get the remote controller wet or leave it in a location with high humidity To avoid misplacing the remote controller install the holder included with the remote controller on a wall and be sure to always place the remote controller in the holder after use For explanation purposes all of the i...

Страница 6: ...ected to the same outdoor unit are already operated in a different mode In this case the rest of the unit in the same group can only be operated in the same mode Automatic operation According to a set temperature cooling operation starts if the room temperature is too hot and heating operation starts if the room temperature is too cold During automatic operation if the room temperature changes and...

Страница 7: ...02 with automatic fan speed If you mistook the operation press the ON OFF button and operate again from procedure Press the SET button with something sharp at the end MODELSELECT and Model No are lighted for 3 seconds then turned off ON OFF TEMP RESET SET CLOCK MODELSELECT FAN VANE TEST RUN AUTO STOP AUTO START h min LOUVER MODE CHECK 3 5 Airflow direction setting 3 5 1 Navigating through the Main...

Страница 8: ... No indication on the remote controller Display of unsupported functions The message at left will appear if the user selects a function not sup ported by the corresponding indoor unit model F1 F2 F3 F4 Title Not available Unsupported function Return 3 5 2 Vane Vent Lossnay Accessing the menu F1 F2 F3 F4 Main Main display Cursor Page Main menu Vane Louver Vent Lossnay High power Timer Weekly timer ...

Страница 9: ...g off Lighting Operation details at the time of emergency operation are as shown below Operation Mode COOL HEAT Set Temperature 24 C 24 C Fan Speed High High Airflow Direction Up and Down Setting 1 Setting 4 5 Cooling Heating Stop Cooling Stop When the remote controller cannot be used When the batteries of the remote controller run out or the remote controller malfunctions the emergency operation ...

Страница 10: ...nstalled in a space with ordinary air quality Depending on the air quality the filter may require more frequent cleaning The cumulative time at which filter needs cleaning depends on the model This indication is not available for wireless remote controller Cleaning the filters Clean the filters using a vacuum cleaner If you do not have a vacuum cleaner tap the filters against a solid object to kno...

Страница 11: ...it If the indoor temperature and the humidity are high this condition may occur when operation starts During defrosting mode cool airflow may blow down and appear like a mist Water or vapor is emitted from the outdoor unit During cool mode water may form and drip from the cool pipes and joints During heat mode water may form and drip from the heat exchanger During defrosting mode water on the heat...

Страница 12: ...e batteries and press the Reset button If nothing appears even after the batteries are replaced make sure that the batteries are installed in the correct directions The operation lamp near the receiver for the wireless remote controller on the indoor unit is flashing The self diagnosis function has operated to protect the air conditioner Do not attempt to repair this equipment by yourself Turn off...

Страница 13: ...ионированный доступ посторонних лиц к приборам этого класса Данны прибор не должен устанавливаться пользователем Обратитесь к поставщику или в специализированное предприятие и закажите установку прибора При неправильной установке может произойти утечка воды электрический шок или пожар Никогда не занимайтесь ремонтом или переносом прибора не кто иной место самостоятельно Не ставьте какие либо посто...

Страница 14: ...ючена нажатие любой кнопки включает подсветку но не приводит к выполнению ее функции кроме кнопки ВКЛ ВЫКЛ Индикатор ВКЛ ВЫКЛ Индикатор будет гореть зеленым цветом когда устройство находится в работе Индикатор будет мигать при включении контроллера или при возникновении ошибки Функциональная кнопка F1 Главное окно нажмите для изменения режима работы Главное меню нажмите чтобы переместить курсор вн...

Страница 15: ... по установке Здесь отображается текущая комнатная температура Отображается когда кнопки заблокированы Полный режим отображения Все значки показаны для иллюстрации и описания Базовый режим отображения Отображается когда включена функция Таймер ВКЛ ВЫКЛ Ночной режим или Автоотключение таймера появляется когда таймер отключен централизованной системой управления Отображается когда включен таймер на ...

Страница 16: ...станционного управления и не подвергайте его сильным ударам Кроме того следите за тем чтобы пульт дистанционного управления не попал в воду и не оставляйте его в местах с высокой влажностью Во избежание неправильного местоположения пульта дистанционного управления установите на стене держатель входящий в комплект поставки пульта дистанционного управления и обязательно устанавливайте пульт дистанци...

Страница 17: ...Нагрев и Auto Авт Cool Room28 5 Auto Set temp Mode Temp Fan Fri 28 5 Пример дисплея по Цельсию с шагом 0 5 градуса F1 F2 F3 F4 Cool Room Auto Set temp Mode Temp Fan Fri Нажмите кнопку F2 чтобы уменьшить заданную температуру а что бы увеличить нажмите кнопку F3 Задаваемые диапазоны температур для различных режимов рабо ты см в таблице на стр 128 Заданный температурных диапазон не может быть установ...

Страница 18: ...ивается как Настройка 01 без автоматической настройки скорости вентилятора Нажмите кнопки установки температуры чтобы выбрать настройку 02 Настройка 02 с автоматической настройкой скорости вентилятора При неправильном выборе операции нажмите кнопку ON OFF ВКЛ ВЫКЛ и вновь начните выполнение операции с пункта Нажмите кнопку SET остроконечным предметом MODELSELECT и номер модели высвечиваются в тече...

Страница 19: ...тройка возможно только когда подключен блок Lossnay Off Low High Off Low High Вентилятор на некоторых моде лях внутренних блоков может блокироваться при использо вании с некоторыми моделями блоков вентиляции Возврат в главное меню F1 F2 F3 F4 Main Main display Cursor Page Main menu Vane Louver Vent Lossnay High power Timer Weekly timer OU silent mode Примечание В режиме качания индикация направлен...

Страница 20: ...пульта дистанционного управления разрядились или в немимеется неисправность аварийный режим можно включить с помощьюаварийных кнопок на решетке Лампа DEFROST STAND BY РАЗМОРАЖИВАНИЕ ОЖИДАНИЕ Оранжевый Лампа работы Зеленый Переключатель аварийной работы обогрев охлаждение Приемник Каждое нажатие кнопки аварийного останова приводит к переключению рабочего режима Проверьте COOL HEAT на мониторе опера...

Страница 21: ...ользованием пылесоса При отсутствии пылесоса легким постукиванием фильтра о твердый предмет стряхните с него грязь или пыль Если фильтры сильно загрязнены промойте их в теплой воде Тщательно смойте остатки моющего средства и полностью просушите фильтры перед их обратной установкой в прибор Осторожно Не сушите фильтры под прямыми солнечными лучами или с использованием источника отопления такого как...

Страница 22: ... В режиме размораживания может подаваться холодный воздушный поток который может казаться дымкой Из наружного прибора выходит вода или пар В режиме охлаждения вода может образовываться и капать с холодных труб и стыков В режиме обогрева вода может образовываться и капать с теплообменника В режиме размораживания вода на теплообменнике испаряется и может появиться водяной пар На дисплее пульта диста...

Страница 23: ... помещении Помещения с высоким уровнем поглощения шума Обычные помещения Помещения с низким уровнем поглощения шума Примеры местоположения Студия радиовещания музыкальная студия и т д Приемная вестибюль гостиницы и т д Офис гостиничный номер Уровни шума от 3 до 7 дБ от 6 до 10 дБ от 9 до 13 дБ На пульте дистанционного управления ничего не отображается дисплей тусклый или внутренний прибор получает...

Страница 24: ... EG representant som är auktoriserad att sammanställa den tekniska filen är följande Avrupa Birliği nde bulunan ve teknik dosyayı düzenleme yetkisine sahip yetkili temsilcimiz aşağıda belirtilmiştir Наш авторизованный представитель в ЕС уполномоченный на составление технического файла указан ниже MITSUBISHI ELECTRIC EUROPE B V HARMAN HOUSE 1 GEORGE STREET UXBRIDGE MIDDLESEX UB8 1QQ U K Yoji SAITO P...

Страница 25: ...eden causar asfixia Se debe proporcionar la ventilación determinada en EN378 1 Asegúrese de colocar el aislante alrededor de las tuberías El contacto directo con la tube ría puede ocasionar quemaduras o congelación Para evitar una ingestión accidental no coloque las pilas en su boca bajo ningún concepto La ingestión de las pilas puede causar asfixia y o envenenamiento Coloque la unidad en una estruc...

Страница 26: ...e be sure to put the contact address telephone number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Printed in Thailand RG79Y672H01 ...

Отзывы: